Assessment of trabecular meshwork width using swept source optical coherence tomography

被引:51
作者
Tun, Tin A. [1 ,2 ]
Baskaran, Mani [1 ,2 ,3 ,4 ]
Zheng, Ce [1 ,2 ,3 ,5 ,6 ]
Sakata, Lisandro M. [7 ]
Perera, Shamira A. [1 ,2 ]
Chan, Anita S. [1 ,2 ,8 ]
Friedman, David S. [9 ]
Cheung, Carol Y. [1 ,2 ,3 ,4 ]
Aung, Tin [1 ,2 ,3 ,4 ]
机构
[1] Singapore Eye Res Inst, Singapore 168751, Singapore
[2] Singapore Natl Eye Ctr, Singapore 168751, Singapore
[3] Natl Univ Singapore, Yong Loo Lin Sch Med, Singapore 117595, Singapore
[4] Natl Univ Singapore, Duke NUS Grad Med Sch, Singapore 117548, Singapore
[5] Shantou Univ, Joint Shantou Int Eye Ctr, Ma Liu Shui, Hong Kong, Peoples R China
[6] Chinese Univ Hong Kong, Ma Liu Shui, Hong Kong, Peoples R China
[7] Univ Fed Parana, BR-80060000 Curitiba, Parana, Brazil
[8] Singapore Gen Hosp, Dept Pathol, Singapore, Singapore
[9] Johns Hopkins Univ, Wilmer Eye Inst, Dana Ctr Prevent Ophthalmol, Baltimore, MD 21218 USA
关键词
Trabecular meshwork; Swept source optical coherence tomography; Quantitative angle measurements; Angle closure; ANTERIOR-CHAMBER ANGLE; ULTRASOUND BIOMICROSCOPY; OCT; TISSUES;
D O I
10.1007/s00417-013-2285-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Measurements of the angle width by ultrasound biomicroscopy or anterior segment optical coherence tomography are usually performed 500 mu m from the scleral spur, as the anterior part of trabecular meshwork (TM) is assumed to lie within this distance. The aim of this study was to measure TM width using swept source optical coherence tomography (SS-OCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan), and to investigate factors influencing this measurement. Participants underwent gonioscopy and SS-OCT imaging in the dark. High-definition SS-OCT images were corrected for refractive distortion; and customized software (ImageJ; National Institutes of Health, Bethesda, MD, USA) was utilized to measure TM width (distance between the scleral spur and Schwalbe's line). Linear regression analysis was performed to assess the relationship between TM width with demographic and angle parameters. One hundred and forty eight Chinese subjects were analyzed. The majority was female (62.4 %); the mean age was 59.2 +/- 8.68 years. Identification of the scleral spur and Schwalbe's line with SS-OCT was possible in 590 (99.7 %) and 585 angle quadrants (98.8 %) respectively. TM width was wider in the inferior and superior quadrants (mean 889 [SD 138] and 793 [136] mu m), compared to the nasal and temporal quadrants (712 [137] and 724 [115] mu m, P < 0.001). There was a difference in average TM width between open (789 [100]) and closed angle eyes (753 [86]) (P = 0.048). There was no significant association between TM width and angle parameters, laterality, or demographic factors. In SS-OCT HD images, the mean TM width varied from 710 to 890 mu m in the different quadrants of the eye, and the inferior quadrant TM was the widest compared to other quadrants.
引用
收藏
页码:1587 / 1592
页数:6
相关论文
共 18 条
[1]   Schlemm's canal and primary open angle glaucoma: Correlation between Schlemm's canal dimensions and outflow facility [J].
Allingham, RR ;
deKater, AW ;
Ethier, CR .
EXPERIMENTAL EYE RESEARCH, 1996, 62 (01) :101-109
[2]  
Chan Y. H., 2003, SMJ Singapore Medical Journal, V44, P391
[3]   Novel anterior-chamber angle measurements by high-definition optical coherence tomography using the Schwalbe line as the landmark [J].
Cheung, Carol Y. ;
Zheng, Ce ;
Ho, Ching-Lin ;
Tun, Tin A. ;
Kumar, Rajesh S. ;
El Sayyad, Fouad ;
Wong, Tien Y. ;
Aung, Tin .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (07) :955-959
[4]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[5]  
Dorairaj Syril, 2007, Trans Am Ophthalmol Soc, V105, P99
[6]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[7]   Anterior chamber angle assessment techniques [J].
Friedman, David S. ;
He, Mingguang .
SURVEY OF OPHTHALMOLOGY, 2008, 53 (03) :250-273
[8]   Automatic Detection of Schwalbe's Line in the Anterior Chamber Angle of the Eye using HD-OCT Images [J].
Jing, Tian ;
Marziliano, Pina ;
Wong, Hon-Tym .
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, :3013-3016
[9]   Trabecular Meshwork Length in Men and Women by Histological Assessment [J].
Kasuga, Toshimitsu ;
Chen, Yi-Chun ;
Bloomer, Michele M. ;
Hirabayashi, Kristin E. ;
Hiratsuka, Yoshimune ;
Murakami, Akira ;
Lin, Shan C. .
CURRENT EYE RESEARCH, 2013, 38 (01) :75-79
[10]   Anterior chamber angle imaging with optical coherence tomography [J].
Leung, C. K-S ;
Weinreb, R. N. .
EYE, 2011, 25 (03) :261-267