Zirconia ceramic fixed partial dentures after cyclic fatigue tests and clinical evaluation: a systematic review

被引:5
作者
Gjurin, Sonja Zarkovic [1 ]
Oezcan, Mutlu [2 ]
Oblak, Cedomir [1 ]
机构
[1] Univ Ljubljana, Fac Med, Dept Prosthodont, Ljubljana, Slovenia
[2] Univ Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Zurich, Switzerland
关键词
Zirconia; fatigue; fixed prosthetic denture; thermocycling; all-ceramic; FPD; in vitro; clinical; LOAD-BEARING CAPACITY; DENTAL PROSTHESES; FRACTURE-RESISTANCE; MECHANICAL FATIGUE; STRENGTH; BRIDGES; FRAMEWORKS; ABUTMENTS; BEHAVIOR; FAILURE;
D O I
10.1080/17436753.2018.1507428
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Zirconia fixed prosthetic dentures are extensively used for replacing missing teeth. The primary objective of this systematic review was to gather and present the results of all in vitro studies and clinical trials conducted on zirconia fixed prosthetic dentures. This review concentrated exclusively on bilayered zirconia and monolithic fixed prosthetic dentures. As such this paper can act as a guideline for more comparable future experimental work on zirconia ceramics. Future studies must use a more systematic approach such as the uniform use of abutment material, material for simulating periodontal support, data about fracture strength before and after fatigue, number of cycles, information about position and size of the indenter. The new digital techniques with long-term follow-up are desirable in further clinical studies.
引用
收藏
页码:62 / 69
页数:8
相关论文
共 58 条
  • [31] A PROSPECTIVE EVALUATION OF ZIRCONIA POSTERIOR FIXED DENTAL PROSTHESES: THREE-YEAR CLINICAL RESULTS
    Pelaez, Jesus
    Cogolludo, Pablo G.
    Serrano, Benjamin
    Lozano, Jose F. L.
    Suarez, Maria J.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (06) : 373 - 379
  • [32] Outcome of zirconia partial fixed dental prostheses made by predoctoral dental students: A clinical retrospective study after 3 to 7 years of clinical service
    Pihlaja, Juha
    Napankangas, Ritva
    Raustia, Aune
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (01) : 40 - 46
  • [33] In vitro failure and fracture resistance of veneered and full-contour zirconia restorations
    Preis, Verena
    Behr, Michael
    Hahnel, Sebastian
    Handel, Gerhard
    Rosentritt, Martin
    [J]. JOURNAL OF DENTISTRY, 2012, 40 (11) : 921 - 928
  • [34] Quinn GD., 2016, FRACTOGRAPHY CERAMIC, p5
  • [35] The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: A prospective clinical pilot study
    Raigrodski, Ariel J.
    Chiche, Gerard J.
    Potiket, Narong
    Hochstedler, J. L.
    Mohamed, Shawky E.
    Billiot, Susan
    Mercante, Donald E.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2006, 96 (04) : 237 - 244
  • [36] Prospective Evaluation of Zirconia Posterior Fixed Partial Dentures: 7-Year Clinical Results
    Rinke, Sven
    Gersdorff, Nikolaus
    Lange, Katharina
    Roediger, Matthias
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2013, 26 (02) : 164 - 171
  • [37] Roediger M, 2010, INT J PROSTHODONT, V23, P141
  • [38] Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures
    Rosentritt, M
    Behr, M
    Gebhard, R
    Handel, G
    [J]. DENTAL MATERIALS, 2006, 22 (02) : 176 - 182
  • [39] Influence of the fabrication process on the in vitro performance of fixed dental prostheses with zirconia substructures
    Rosentritt, Martin
    Kolbeck, Carola
    Handel, Gerhard
    Schneider-Feyrer, Sibylle
    Behr, Michael
    [J]. CLINICAL ORAL INVESTIGATIONS, 2011, 15 (06) : 1007 - 1012
  • [40] Rosentritt M, 2011, INT J PROSTHODONT, V24, P465