Zirconia ceramic fixed partial dentures after cyclic fatigue tests and clinical evaluation: a systematic review

被引:5
作者
Gjurin, Sonja Zarkovic [1 ]
Oezcan, Mutlu [2 ]
Oblak, Cedomir [1 ]
机构
[1] Univ Ljubljana, Fac Med, Dept Prosthodont, Ljubljana, Slovenia
[2] Univ Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Zurich, Switzerland
关键词
Zirconia; fatigue; fixed prosthetic denture; thermocycling; all-ceramic; FPD; in vitro; clinical; LOAD-BEARING CAPACITY; DENTAL PROSTHESES; FRACTURE-RESISTANCE; MECHANICAL FATIGUE; STRENGTH; BRIDGES; FRAMEWORKS; ABUTMENTS; BEHAVIOR; FAILURE;
D O I
10.1080/17436753.2018.1507428
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Zirconia fixed prosthetic dentures are extensively used for replacing missing teeth. The primary objective of this systematic review was to gather and present the results of all in vitro studies and clinical trials conducted on zirconia fixed prosthetic dentures. This review concentrated exclusively on bilayered zirconia and monolithic fixed prosthetic dentures. As such this paper can act as a guideline for more comparable future experimental work on zirconia ceramics. Future studies must use a more systematic approach such as the uniform use of abutment material, material for simulating periodontal support, data about fracture strength before and after fatigue, number of cycles, information about position and size of the indenter. The new digital techniques with long-term follow-up are desirable in further clinical studies.
引用
收藏
页码:62 / 69
页数:8
相关论文
共 58 条
  • [1] ZrO2 three-unit fixed partial dentures:: comparison of failure load before and after exposure to a mastication simulator
    Att, W.
    Grigoriadou, M.
    Strub, J. R.
    [J]. JOURNAL OF ORAL REHABILITATION, 2007, 34 (04) : 282 - 290
  • [2] Thermal-induced residual stresses affect the fractographic patterns of zirconia-veneer dental prostheses
    Belli, Renan
    Petschelt, Anselm
    Lohbauer, Ulrich
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 21 : 167 - 177
  • [3] Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/computer-aided manufacturing (CAM) fabricated framework materials
    Beuer, Florian
    Steff, Bastian
    Naumann, Michael
    Sorensen, John A.
    [J]. EUROPEAN JOURNAL OF ORAL SCIENCES, 2008, 116 (04) : 381 - 386
  • [4] Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs)
    Beuer, Florian
    Edelhoff, Daniel
    Gernet, Wolfgang
    Sorensen, John A.
    [J]. CLINICAL ORAL INVESTIGATIONS, 2009, 13 (04) : 445 - 451
  • [5] Five-year clinical evaluation of zirconia-based bridges in patients in UK general dental practices
    Burke, F. J. T.
    Crisp, R. J.
    Cowan, A. J.
    Lamb, J.
    Thompson, O.
    Tulloch, N.
    [J]. JOURNAL OF DENTISTRY, 2013, 41 (11) : 992 - 999
  • [6] Fracture Strength, Failure Types, and Weibull Characteristics of Three-Unit Zirconia Fixed Dental Prostheses After Cyclic Loading: Effects of Veneering and Air-Abrasion Protocols
    Campos, Femanda
    Souza, Rodrigo O. A.
    Bottino, Marco A.
    Ozcan, Mutiu
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2016, 36 (06) : 901 - 908
  • [7] Fracture strength of implant abutments after fatigue testing: A systematic review and a meta-analysis
    Coray, Rafaela
    Zeltner, Marco
    Ozcan, Mutlu
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 62 : 333 - 346
  • [8] A clinical evaluation of all-ceramic bridges placed in UK general dental practices: first-year results
    Crisp, R. J.
    Cowan, A. J.
    Lamb, J.
    Thompson, O.
    Tulloch, N.
    Burke, F. J. T.
    [J]. BRITISH DENTAL JOURNAL, 2008, 205 (09) : 477 - 482
  • [9] Edelhoff D, 2008, QUINTESSENCE INT, V39, P459
  • [10] Fatigue Behavior of Zirconia-Ceramic, Galvano-Ceramic, and Porcelain-Fused-to-Metal Fixed Partial Dentures
    Eroglu, Zekiye
    Gurbulak, Aysegul G.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2013, 22 (07): : 516 - 522