Sensitive detection of virus with broad dynamic range based on highly bright quantum dot-embedded nanoprobe and magnetic beads

被引:13
作者
Jo, Ahla [1 ]
Kim, Tae Han [1 ]
Kim, Dong-Min [1 ]
Kim, Hyung-Mo [1 ]
Seong, Bomi [1 ]
Kim, Jaehi [1 ]
Pham, Xuan-Hung [1 ]
Jung, Heung Su [2 ]
Lee, Sang Hun [3 ]
Hwang, Do Won [4 ]
Jeong, Dae Hong [5 ]
Lee, Yoon-Sik [3 ]
Kim, Dong-Eun [1 ]
Jun, Bong-Hyun [1 ]
机构
[1] Konkuk Univ, Dept Biosci & Biotechnol, Seoul 05029, South Korea
[2] Co Global Zeus, Osan 18148, Gyeonggi Do, South Korea
[3] Seoul Natl Univ, Sch Chem & Biol Engn, Seoul 08826, South Korea
[4] Seoul Natl Univ, Dept Nucl Med, Seoul 03080, South Korea
[5] Seoul Natl Univ, Coll Chem Educ, Seoul 08826, South Korea
基金
新加坡国家研究基金会;
关键词
QD-embedded silica nanoparticles; Magnetic beads; Sandwich immunoassay; Avian virus detection; Sensitive detection; INFLUENZA-VIRUS; RAPID DETECTION; DIAGNOSIS; ASSAY; H5N1;
D O I
10.1016/j.jiec.2020.07.030
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
As virus spread can lead to severe epidemics and pandemics associated with high mortality, it is necessary to have a highly sensitive detection method for viruses. Although various detection methods have been developed so far, current methods in detecting a virus require preprocessing and involve quite intricate processes of low sensitivity. Here, we have developed a virus detection method with a broad dynamic range and high sensitivity, based on immuno-complex formation between quantum dot (QD)-embedded silica nanoparticles (QD(2)) and magnetic beads. The multiple QD- containing QD(2)s showed 500 times stronger photoluminescence than individual QDs. When biotin was immobilized as a ligand, streptavidin was detected in a range of 10 zM to 10 nM. The clinical applicability of the QD(2)-based system was examined using the avian virus (i.e., H1N1 influenza virus), and it showed a detection range of 4.76 x 10(-4)< span class="xps_thinspace"> similar to 3.2 hemagglutination unit/mL. This result is comparable to the polymerase chain reaction method, and is approximately 2100 times more sensitive than the conventional hemagglutination method. Since the QD(2)-based system could detect target molecules with high sensitivity without requiring an amplification step, it can be applied in various biomedical and clinical fields. (C) 2020 The Korean Society of Industrial and Engineering Chemistry. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:319 / 326
页数:8
相关论文
共 35 条
[1]   A PRACTICAL SCORE FOR THE EARLY DIAGNOSIS OF ACUTE APPENDICITIS [J].
ALVARADO, A .
ANNALS OF EMERGENCY MEDICINE, 1986, 15 (05) :557-564
[2]  
Chang Shih-Cheng, 2006, Chang Gung Med J, V29, P130
[3]   CHARACTERISTICS OF MICROPLATE METHOD OF ENZYME-LINKED IMMUNOSORBENT ASSAY FOR DETECTION OF PLANT-VIRUSES [J].
CLARK, MF ;
ADAMS, AN .
JOURNAL OF GENERAL VIROLOGY, 1977, 34 (MAR) :475-483
[4]  
Dinh PN, 2006, EMERG INFECT DIS, V12, P1841
[5]   Detection Methods of Human and Animal Influenza Virus-Current Trends [J].
Dziabowska, Karolina ;
Czaczyk, Elzbieta ;
Nidzworski, Dawid .
BIOSENSORS-BASEL, 2018, 8 (04)
[6]   RAPID DETECTION OF INFLUENZA-VIRUS BY SHELL VIAL ASSAY WITH MONOCLONAL-ANTIBODIES [J].
ESPY, MJ ;
SMITH, TF ;
HARMON, MW ;
KENDAL, AP .
JOURNAL OF CLINICAL MICROBIOLOGY, 1986, 24 (04) :677-679
[7]  
GARRETT S, 1994, J RHEUMATOL, V21, P2286
[8]  
Girard MP, 2010, VACCINE, V28, P4895, DOI [10.1016/j.vaccine.2010.05.031, 10.1016/j.vaccine.2010.07.034]
[9]   Quantum-dot-tagged microbeads for multiplexed optical coding of biomolecules [J].
Han, MY ;
Gao, XH ;
Su, JZ ;
Nie, S .
NATURE BIOTECHNOLOGY, 2001, 19 (07) :631-635
[10]   Surface plasmon resonance sensors for detection of chemical and biological species [J].
Homola, Jiri .
CHEMICAL REVIEWS, 2008, 108 (02) :462-493