Evaluation of three-dimensional printing for internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach: a preliminary report

被引:2
作者
Zeng, Canjun [1 ,2 ]
Xiao, Jidong [3 ]
Wu, Zhanglin [1 ]
Huang, Wenhua [1 ]
机构
[1] Southern Med Univ, Sch Basic Med Sci, Guangdong Prov Key Lab Med Biomech, Dept Anat, Guangzhou 510515, Guangdong, Peoples R China
[2] Southern Med Univ, Affiliated Hosp 3, Acad Othoped Guangdong Prov, Dept Orthoped, Guangzhou 510630, Guangdong, Peoples R China
[3] Cent S Univ, Xiangya Hosp 3, Dept Ultrasound Imaging, Changsha, Hunan, Peoples R China
来源
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE | 2015年 / 8卷 / 08期
关键词
3D printing; minimally invasive; pelvic fracture; internal fixation; para-rectus abdominis approach; ACETABULAR FRACTURES; RING FRACTURES; CALCIUM-PHOSPHATE; MANAGEMENT; SCAFFOLDS; MORTALITY;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: The aim of this study is to evaluate the efficacy and feasibility of three-dimensional printing (3D printing) assisted internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach. Methods: A total of 38 patients with unstable pelvic fractures were analyzed retrospectively from August 2012 to February 2014. All cases were treated operatively with internal fixation assisted by three-dimensional printing from minimal invasive para-rectus abdominis approach. Both preoperative CT and three-dimensional reconstruction were performed. Pelvic model was created by 3D printing. Data including the best entry points, plate position and direction and length of screw were obtained from simulated operation based on 3D printing pelvic model. The diaplasis and internal fixation were performed by minimal invasive para-rectus abdominis approach according to the optimized dada in real surgical procedure. Matta and Majeed score were used to evaluate currative effects after operation. Results: According to the Matta standard, the outcome of the diaplasis achieved 97.37% with excellent and good. Majeed assessment showed 94.4% with excellent and good. The imageological examination showed consistency of internal fixation and simulated operation. The mean operation time was 110 minutes, mean intraoperative blood loss 320 ml, and mean incision length 6.5 cm. All patients have achieved clinical healing, with mean healing time of 8 weeks. Conclusion: Three-dimensional printing assisted internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach is feasible and effective. This method has the advantages of trauma minimally, bleeding less, healing rapidly and satisfactory reduction, and worthwhile for spreading in clinical practice.
引用
收藏
页码:13039 / 13044
页数:6
相关论文
共 21 条
[21]   Printability of calcium phosphate: Calcium sulfate powders for the application of tissue engineered bone scaffolds using the 3D printing technique [J].
Zhou, Zuoxin ;
Buchanan, Fraser ;
Mitchell, Christina ;
Dunne, Nicholas .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 38 :1-10