Evaluation of three-dimensional printing for internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach: a preliminary report

被引:2
作者
Zeng, Canjun [1 ,2 ]
Xiao, Jidong [3 ]
Wu, Zhanglin [1 ]
Huang, Wenhua [1 ]
机构
[1] Southern Med Univ, Sch Basic Med Sci, Guangdong Prov Key Lab Med Biomech, Dept Anat, Guangzhou 510515, Guangdong, Peoples R China
[2] Southern Med Univ, Affiliated Hosp 3, Acad Othoped Guangdong Prov, Dept Orthoped, Guangzhou 510630, Guangdong, Peoples R China
[3] Cent S Univ, Xiangya Hosp 3, Dept Ultrasound Imaging, Changsha, Hunan, Peoples R China
来源
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE | 2015年 / 8卷 / 08期
关键词
3D printing; minimally invasive; pelvic fracture; internal fixation; para-rectus abdominis approach; ACETABULAR FRACTURES; RING FRACTURES; CALCIUM-PHOSPHATE; MANAGEMENT; SCAFFOLDS; MORTALITY;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: The aim of this study is to evaluate the efficacy and feasibility of three-dimensional printing (3D printing) assisted internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach. Methods: A total of 38 patients with unstable pelvic fractures were analyzed retrospectively from August 2012 to February 2014. All cases were treated operatively with internal fixation assisted by three-dimensional printing from minimal invasive para-rectus abdominis approach. Both preoperative CT and three-dimensional reconstruction were performed. Pelvic model was created by 3D printing. Data including the best entry points, plate position and direction and length of screw were obtained from simulated operation based on 3D printing pelvic model. The diaplasis and internal fixation were performed by minimal invasive para-rectus abdominis approach according to the optimized dada in real surgical procedure. Matta and Majeed score were used to evaluate currative effects after operation. Results: According to the Matta standard, the outcome of the diaplasis achieved 97.37% with excellent and good. Majeed assessment showed 94.4% with excellent and good. The imageological examination showed consistency of internal fixation and simulated operation. The mean operation time was 110 minutes, mean intraoperative blood loss 320 ml, and mean incision length 6.5 cm. All patients have achieved clinical healing, with mean healing time of 8 weeks. Conclusion: Three-dimensional printing assisted internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach is feasible and effective. This method has the advantages of trauma minimally, bleeding less, healing rapidly and satisfactory reduction, and worthwhile for spreading in clinical practice.
引用
收藏
页码:13039 / 13044
页数:6
相关论文
共 21 条
[1]   Outcomes of acetabular fracture fixation with ten years' follow-up [J].
Briffa, N. ;
Pearce, R. ;
Hill, A. M. ;
Bircher, M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (02) :229-236
[2]   Recent advances in 3D printing of biomaterials [J].
Chia, Helena N. ;
Wu, Benjamin M. .
JOURNAL OF BIOLOGICAL ENGINEERING, 2015, 9
[3]  
COLE JD, 1994, CLIN ORTHOP RELAT R, P112
[4]   Management and outcome of pelvic fractures in elderly patients: a retrospective study of 40 cases [J].
Dong Jinlei ;
Hao Wei ;
Wang Bomin ;
Wang Lubo ;
Li Lianxin ;
Mu Weidong ;
Yang Yongliang ;
Xin Maoyuan ;
Wang Fu ;
Zhou Dongsheng .
CHINESE MEDICAL JOURNAL, 2014, 127 (15) :2802-2807
[5]   Pelvic ring fractures: has mortality improved following the implementation of damage control resuscitation? [J].
Fitzgerald, Caitlin A. ;
Morse, Bryan C. ;
Dente, Christopher J. .
AMERICAN JOURNAL OF SURGERY, 2014, 208 (06) :1083-1089
[6]  
HELFET DL, 1994, CLIN ORTHOP RELAT R, P58
[7]   3D printing of composite calcium phosphate and collagen scaffolds for bone regeneration [J].
Inzana, Jason A. ;
Olvera, Diana ;
Fuller, Seth M. ;
Kelly, James P. ;
Graeve, Olivia A. ;
Schwarz, Edward M. ;
Kates, Stephen L. ;
Awad, Hani A. .
BIOMATERIALS, 2014, 35 (13) :4026-4034
[8]   Minimally invasive plate osteosynthesis using 3D Printing for shaft fractures of clavicles: technical note [J].
Jeong, Ho-Seung ;
Park, Kyoung-Jin ;
Kil, Kyung-Min ;
Chong, Suri ;
Eun, Hyeon-Jun ;
Lee, Tae-Soo ;
Lee, Jeong-Pyo .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (11) :1551-1555
[9]   Functional outcome of open reduction and internal fixation for completely unstable pelvic ring fractures (Type C) - A report of 40 cases [J].
Kabak, S ;
Halici, M ;
Tuncel, M ;
Avsarogullari, L ;
Baktir, A ;
Basturk, M .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (08) :555-562
[10]   The Pararectus approach for anterior intrapelvic management of acetabular fractures AN ANATOMICAL STUDY AND CLINICAL EVALUATION [J].
Keel, M. J. B. ;
Ecker, T. M. ;
Cullmann, J. L. ;
Bergmann, M. ;
Bonel, H. M. ;
Buechler, L. ;
Siebenrock, K. A. ;
Bastian, J. D. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (03) :405-411