Seismic performance of a new through rib stiffener beam connection to concrete-filled steel tubular columns: An experimental study

被引:34
作者
Jeddi, Mandi Zeinizadeh [1 ]
Sulong, N. H. Ramli [1 ]
Khanouki, M. M. Arabnejad [1 ]
机构
[1] Univ Malaya, Fac Engn, Dept Civil Engn, Kuala Lumpur 50603, Malaysia
关键词
Beam to concrete-filled tubular (CFT) column connection; Through-rib stiffener; Cyclic loading; Seismic performance; Ductility; Energy dissipation; BOX-COLUMN; I-BEAM; CFT COLUMN; EXPERIMENTAL BEHAVIOR; TUBE COLUMN; DESIGN; JOINTS; END;
D O I
10.1016/j.engstruct.2016.10.038
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper proposes a new moment-resisting connection known as a through rib stiffener beam connection, which is directly passed through a pre-slotted circular column with concrete infill. Four half-scale cruciform specimens with orthogonal beams were tested under cyclic loading. The failure modes, hysteretic performance, rotation capacity, strength and stiffness degradation, ductility, and energy dissipation of the connections were analysed. The effect of different parameters, such as through rib stiffener and beam section size, on the connection performance was investigated. The experimental results indicated that the new through rib stiffener beam connected with circular columns exhibited a large hysteretic enclosed area, good ductility, and excellent energy dissipation. The results proved that the proposed connection satisfies the seismic provisions and ductility design requirements for it to be utilized as moment-resisting frames in a seismically active area. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:477 / 491
页数:15
相关论文
共 45 条
  • [1] [Anonymous], 2004, EUROCODE 8 DESIGN ST
  • [2] [Anonymous], 2000, Prestandard and Commentary for the Seismic Rehabilitation of Buildings
  • [3] [Anonymous], 2012, Standard Test Methods for Tension Testing of Metallic Materials, DOI 10.1520/F2792-12A
  • [4] [Anonymous], 2010, 36010 ANSIAISC
  • [5] [Anonymous], 1994, ASCE Journal of Structural Engineering, V120, P2330
  • [6] [Anonymous], 2008, ACI 318-08) and commentary
  • [7] ANSI, 2010, 34110 ANSIAISC
  • [8] Applied Technology Council (ATC), 1992, ATC-24
  • [9] DESIGN OF THROUGH BEAM CONNECTION DETAIL FOR CIRCULAR COMPOSITE COLUMNS
    AZIZINAMINI, A
    SHEKAR, Y
    SAADEGHVAZIRI, MA
    [J]. ENGINEERING STRUCTURES, 1995, 17 (03) : 209 - 213
  • [10] Bergmann R., 1995, Design guide for concrete filled hollow section columns under static and seismic loading (CIDECT). Eds.)