A New Inrush Current Identification Algorithm Based on Transformer Core Saturation

被引:0
|
作者
Jin, Ming [1 ]
Liu, Yuanlong [2 ]
机构
[1] GE Grid Software Solut, Redmond, WA 98052 USA
[2] Shandong Elect Power Dispatching & Control Ctr, Jinan 250001, Shandong, Peoples R China
来源
2017 IEEE POWER & ENERGY SOCIETY GENERAL MEETING | 2017年
关键词
Flux Restrained Current Differential Relay; Inrush Current Identification; Percentage Restrained Differential Protection; Power Transformer Protection; DIFFERENTIAL RELAY; POWER TRANSFORMERS; PROTECTION;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Percentage restrained differential protection is widely used as the main protection of bulk power transformers. For any differential current based transformer protection scheme, an important problem is to distinguish the magnetizing inrush from faults to prevent the possible mal-operation of differential relays. Traditionally, the second harmonic restraint principle is adopted as the standard method to maintain the security of relays during the inrush events. In recent years, the improvement of the magnetic characteristics of transformer iron core materials led to the relatively lower second harmonic components in magnetizing inrush currents; in contrast, higher second harmonic components in short circuit currents due to CT saturation and the effect of distributed capacitance of the EHV long line connected to the protected transformer have been observed, which makes the choosing of an appropriate harmonic restraint ratio more difficult. In this paper, a fast flux restraint algorithm used to identify the magnetizing inrush current is presented. Based on the sampled voltage/current values, the algorithm calculates the changing rate of magnetic fluxes in iron core to determine the saturation status of the protected transformer. The saturation status is traced by a group of counters. The counter threshold derived from testing is used to determine if the relay should be blocked. The proposed algorithm can be applied to all kinds of transformer iron core structures and its effectiveness can be verified through the test cases.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Compensation of Current Transformer Saturation Based on Improved ESPRIT Algorithm
    Guan, Jun
    Hao, Zhiguo
    Chen, Wenzhe
    Liu, Zhiyuan
    Yu, Xiaojun
    2016 IEEE 16TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2016,
  • [22] Transformer Inrush Current Identification in Coal Mine Based on Wavelet-DHNN
    Li, Lanbing
    Gong, Maofa
    Wang, Zhiwen
    Yan, Honglin
    Zhang, Jianyu
    Zhu, Jingjie
    PROCEEDINGS OF THE 2013 INTERNATIONAL CONFERENCE ON ENERGY, 2013, : 168 - 172
  • [23] Effect of Core Inrush Current of Three-Phases Transformer
    Negara, I. Made Yulistya
    Fahmi, Daniar
    Asfani, Dimas A.
    Kumiawan, Naufal Arif
    2016 3RD CONFERENCE ON POWER ENGINEERING AND RENEWABLE ENERGY (ICPERE), 2016, : 69 - 74
  • [24] Identification criterion of transformer magnetizing inrush current based on symbol sequence characteristic of differential current
    Weng H.
    Mei H.
    Guo Y.
    Jia Y.
    Li Z.
    Huang J.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2022, 42 (06): : 206 - 211
  • [25] Restoration of the current transformer secondary current under core saturation conditions based on ANN
    Odinaev, Ismoil
    Abdel-Aty, Abdel-Haleem
    Pazderin, Andrey
    Safaraliev, Murodbek
    Matrenin, Pavel
    Senyuk, Mihail
    Menaem, Amir Abdel
    Kanan, Mohammad
    HELIYON, 2024, 10 (18)
  • [26] Analysis of inrush and fault currents measurement errors generated by the current transformer saturation
    Radu, Razvan-Andrei
    Micu, Dan Ovidiu
    Micu, Dan Doru
    Ceclan, Andrei
    2014 49TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2014,
  • [27] Magnetizing Inrush Identification Method of Power Transformer Considering CT Saturation Interference
    Liu P.
    Jiao B.
    Guo X.
    Dianwang Jishu/Power System Technology, 2022, 46 (09): : 3633 - 3641
  • [28] Identification of transformer inrush current using morphological signal decomposition
    Dept. of Elec. Eng. and Electron., Univ. of Liverpool, Liverpool L69 3GJ, United Kingdom
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2002, 26 (SUPPL.): : 67 - 69
  • [29] New Algorithm to Identify Inrush Current Based on Improved EMD
    Chen Dazhuang
    Huang Jiadong
    Sun Yang
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 6927 - 6934
  • [30] Identification Inrush Current and Internal Faults of Transformer based on Hyperbolic S-transform
    Zhang, Qing
    Jiao, Shangbin
    Wang, Sha
    ICIEA: 2009 4TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-6, 2009, : 258 - 263