Feasibility Study of Co-Firing of Torrefied Empty Fruit Bunch and Coal through Boiler Simulation

被引:14
作者
Jiang, Yu [1 ]
Park, Kyeong-Hoon [1 ]
Jeon, Chung-Hwan [1 ,2 ]
机构
[1] Pusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
[2] Pusan Natl Univ, Pusan Clean Coal Ctr, Busan 46241, South Korea
关键词
torrefaction; empty fruit bunch; co-firing; simulation; exhaust gas emission; tangential firing boiler; FLUIDIZED-BED; NUMERICAL-SIMULATION; POWER-GENERATION; BIOMASS; COMBUSTION; TORREFACTION; EFFICIENT; KINETICS; SYSTEM; DRY;
D O I
10.3390/en13123051
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Torrefied empty fruit bunch (EFB) co-firing is a promising technology to reduce emissions from coal-fired power plants. However, co-firing can influence the combustion and heat transfer characteristics in a coal boiler. In order to study the feasibility of co-firing application of torrefied EFB (T-EFB) in boilers, the combustion characteristics, gas emissions and heat flux distribution were analyzed, respectively. First, the kinetic parameters of T-EFB devolatilization and char oxidation were obtained by experimental analysis. Second, the computational fluid dynamics (CFD) analysis was applied to the actual 500 MWe boiler simulation to further evaluate the differences in the co-firing performance parameters (combustion characteristics and emissions) of the T-EFB and the heat transfer characteristics within the boiler. Numerical results show that T-EFB co-firing can improve the ignition characteristics of pulverized coal, reduce the formation of unburned particles. When the blending ratio was increased from 10% to 50%, significantly NOx(oxides of nitrogen) reduction (levels from 170 to 98 ppm at 6% O-2) was achieved. At a blending ratio above 40%, boiler combustion efficiency decreases as the total heat flux of the boiler decreases due to an increase in the amount of unburned carbon. In addition, T-EFB co-firing can affect the heat transfer characteristics of the boiler.
引用
收藏
页数:23
相关论文
共 46 条
[11]   A combustion concept for oxyfuel processes with low recirculation rate - Experimental validation [J].
Becher, Valentin ;
Bohn, Jan-Peter ;
Goanta, Adrian ;
Spliethoff, Hartmut .
COMBUSTION AND FLAME, 2011, 158 (08) :1542-1552
[12]  
Bergman P.C.A., 2005, 200505013 ECNC
[13]   Numerical investigation on the flow, combustion and NOx emission characteristics in a 500 MWe tangentially fired pulverized-coal boiler [J].
Choi, Choeng Ryul ;
Kim, Chang Nyung .
FUEL, 2009, 88 (09) :1720-1731
[14]   Energetic assessment of a combined heat and power integrated biomass gasification-internal combustion engine system by using Aspen Plus® [J].
Damartzis, Th. ;
Michailos, S. ;
Zabaniotou, A. .
FUEL PROCESSING TECHNOLOGY, 2012, 95 :37-44
[15]   Retrofitting existing coal power plants through cofiring with hydrothermally treated empty fruit bunch and a novel integrated system [J].
Darmawan, Arif ;
Budianto, Dwika ;
Aziz, Muhammad ;
Tokimatsu, Koji .
APPLIED ENERGY, 2017, 204 :1138-1147
[16]  
de Soete G G., 1975, Symposium (International) on Combustion, P1093, DOI [10.1016/S0082-0784(75)80374-2, DOI 10.1016/S0082-0784(75)80374-2]
[17]  
Emad R, 2018, FUEL, V211, P363
[18]   DRAG COEFFICIENT AND TERMINAL VELOCITY OF SPHERICAL AND NONSPHERICAL PARTICLES [J].
HAIDER, A ;
LEVENSPIEL, O .
POWDER TECHNOLOGY, 1989, 58 (01) :63-70
[19]  
Hanson RK, 1984, SURVEY RATE CONSTANT, P361, DOI [10.1007/978-1-4684-0186-8_6, DOI 10.1007/978-1-4684-0186-8_6]
[20]   Simulation studies on direct ash recycling and reburning technology in a tangentially fired 500 MW pulverized coal boiler [J].
Hwang, Min-young ;
Kim, Seung-mo ;
Kim, Gyu-bo ;
Lee, Byoung-hwa ;
Song, Ju-hun ;
Park, Myung-suk ;
Jeon, Chung-hwan .
FUEL, 2013, 114 :78-87