Electromagnetic and Mechanical Analysis and Measurements of Interior Permanent Magnet Motors Based on Equivalent Magnetic Circuit Method

被引:2
作者
Lee, Young-Keun [1 ]
Bang, Tae-Kyoung [2 ]
Jo, Seong-Tae [1 ]
Kim, Yong-Joo [3 ]
Shin, Kyung-Hun [4 ]
Choi, Jang-Young [1 ]
机构
[1] Chungnam Natl Univ, Dept Elect Engn, Daejeon 34134, South Korea
[2] Hyundai Mobis, Adv Brake Syst Engn Cell, Yongin 16891, South Korea
[3] Chungnam Natl Univ, Dept Smart Agr Syst, Daejeon 34134, South Korea
[4] Chonnam Natl Univ, Dept Power Syst Engn, Jeonnam 59626, South Korea
基金
新加坡国家研究基金会;
关键词
equivalent magnetic circuit; magnetic field analysis; permanent magnet; interior permanent magnet motor; stress analysis; TORQUE; DESIGN;
D O I
10.3390/machines10100915
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper is about the magnetic field analysis of an interior permanent magnet motor (IPM motor) by using the equivalent magnetic circuit method (EMC method), which requires a small amount of computation time compared with the finite element method (FEM). IPM motors have a specific shape of rotor in which the permanent magnets are embedded. Therefore, in the bridge region, the magnetic saturation is generated due to the shape of the permanent magnet, which affects the magnetic flux density distribution in the air gap and the characteristics of the IPM motor. Thus, to design an IPM motor, the magnetic saturation effects should be considered along with the rotor shape. In addition, because the rotor of the IPM rotates at a high speed directly in connection with the load, the stress generated from the rotor must be stably distributed. Consequently, according to the rotor shape characteristics of the IPM, the stress is concentrated in the thin bridge region during high-speed rotation. When the stress generated in the bridge region exceeds the yield stress of the rotor iron core material, the bridge part is destroyed. Therefore, it is important to analyze the stress that occurs in the rotor during high-speed rotation in the rotor design stage of the IPM. In this study, we analyzed the magnetic field characteristics of an IPM motor using its equivalent magnetic circuit while considering the magnetic saturation in the bridge region. The stability of the rotor was determined by presenting a safety factor based on the maximum stress generated at the rotor for each speed. We derived the stator natural frequency to evaluate the resonance possibility between the electrical frequency and the stator natural frequency. Finally, the validity of the constructed equivalent magnetic circuit was verified by comparing the results with those obtained via the FEM analysis and experiments.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Magnetic Circuit Analysis of Interior Magnet Synchronous Motors
    Ghahfarokhi, Mohammadreza Mostafavi
    Aliabad, Aliakbar Damaki
    Boroujeni, Samad Taghipour
    Amiri, Ebrahim
    Faradonbeh, Vahid Zamani
    2020 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE & EXPO (ITEC), 2020, : 434 - 438
  • [2] Equivalent Circuit Modeling of an Interior Permanent Magnet Hysteresis Motor
    Rabbi, S. F.
    Rahman, M. A.
    2014 IEEE 27TH CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2014,
  • [3] Electromagnetic Modeling and Analysis of 3-DOF Permanent Magnet Spherical Motor Using Magnetic Equivalent Circuit Method
    Cheng, Gaomei
    Guo, Xiwen
    Wen, Yan
    Wang, Qunjing
    Li, Guoli
    Zhou, Rui
    2018 21ST INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2018, : 2643 - 2648
  • [4] Magnetic Field Analysis of 3-DOF Permanent Magnetic Spherical Motor Using Magnetic Equivalent Circuit Method
    Li, Bin
    Li, Gui-Dan
    Li, Hong-Feng
    IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (08) : 2127 - 2133
  • [6] Rotor topology optimization and electromagnetic performance analysis of interior permanent magnet synchronous motors for electric vehicle applications
    Niu, Lianbo
    Zhang, Mingzhu
    JOURNAL OF ENGINEERING-JOE, 2023, 2023 (02):
  • [7] Magnetic field modeling and analysis for permanent magnet synchronous linear motors
    Qian, Junbing
    Bao, Liping
    Ji, Chuankun
    Wu, Jing
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2019, 60 (02) : 209 - 221
  • [8] Design and Analysis of Interior Permanent Magnet Synchronous Motor Considering Saturated Rotor Bridge using Equivalent Magnetic Circuit
    Shin, Kyung-Hun
    Yu, Ju-Seong
    Choi, Jang-Young
    Cho, Han-Wook
    JOURNAL OF MAGNETICS, 2014, 19 (04) : 404 - 410
  • [9] Impact of Mechanical Stress on Characteristics of Interior Permanent Magnet Synchronous Motors
    Yamazaki, Katsumi
    Takeuchi, Hidetada
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (02) : 963 - 970
  • [10] Impact of Mechanical Stress on Characteristics of Interior Permanent Magnet Synchronous Motors
    Yamazaki, Katsumi
    Takeuchi, Hidetada
    2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 4391 - 4396