Characterization of high-purity germanium detectors with amorphous germanium contacts in cryogenic liquids

被引:5
|
作者
Panth, R. [1 ]
Liu, J. [1 ]
Abt, I. [2 ]
Liu, X. [2 ]
Schulz, O. [2 ]
Wei, W. -Z. [1 ]
Mei, H. [1 ]
Mei, D. -M. [1 ]
Wang, G. -J. [1 ]
机构
[1] Univ South Dakota, 414 East Clark St, Vermillion, SD 57069 USA
[2] Max Planck Inst Phys & Astrophys, Fohringer Ring 6, D-80805 Munich, Germany
来源
EUROPEAN PHYSICAL JOURNAL C | 2020年 / 80卷 / 07期
关键词
NEUTRINO MASS; DARK-MATTER; VMSM;
D O I
10.1140/epjc/s10052-020-8235-9
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
For the first time, planar high-purity germanium detectors with thin amorphous germanium contacts were successfully operated directly in liquid nitrogen and liquid argon in a cryostat at the Max-Planck-Institut fur Physics in Munich. The detectors were fabricated at the Lawrence Berkeley National Laboratory and the University of South Dakota, using crystals grown at the University of South Dakota. They survived long-distance transportation and multiple thermal cycles in both cryogenic liquids and showed reasonable leakage currents and spectroscopic performance. Also discussed are the pros and cons of using thin amorphous semiconductor materials as an alternative contact technology in large-scale germanium experiments searching for physics beyond the Standard Model.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Characterization of high-purity germanium detectors with amorphous germanium contacts in cryogenic liquids
    R. Panth
    J. Liu
    I. Abt
    X. Liu
    O. Schulz
    W.-Z. Wei
    H. Mei
    D.-M. Mei
    G.-J. Wang
    The European Physical Journal C, 2020, 80
  • [2] Fabrication and characterization of high-purity germanium detectors with amorphous germanium contacts
    Meng, X-H
    Wang, G-J
    Wagner, M-D
    Mei, H.
    Wei, W-Z
    Liu, J.
    Yang, G.
    Mei, D-M
    JOURNAL OF INSTRUMENTATION, 2019, 14 (02)
  • [3] Leakage current in high-purity germanium detectors with amorphous semiconductor contacts
    Looker, Q.
    Amman, M.
    Vetter, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 777 : 138 - 147
  • [4] Optimization of Process Parameters for Amorphous Semiconductor Contacts on High-Purity Germanium Detectors
    Looker, Q.
    Amman, M.
    Vetter, K.
    Barton, P.
    Luke, P. N.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 222 - 227
  • [5] AMORPHOUS-GERMANIUM AS AN ELECTRON OR HOLE BLOCKING CONTACT ON HIGH-PURITY GERMANIUM DETECTORS
    HANSEN, WL
    HALLER, EE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 61 - 63
  • [6] Inter-electrode charge collection in high-purity germanium detectors with amorphous semiconductor contacts
    Looker, Q.
    Amman, M.
    Vetter, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 781 : 20 - 25
  • [7] Segmented high-purity germanium detectors
    Gurov, Yu. B.
    Gusev, K. N.
    Katualina, S. L.
    Sandukovsky, V. G.
    Borowicz, D.
    Yurkowski, J.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2007, 50 (06) : 757 - 760
  • [8] PLANAR DETECTORS OF HIGH-PURITY GERMANIUM
    GORNOV, MG
    GUROV, YB
    OSIPENKO, BP
    PODKOPAEV, OI
    SOLDATOV, AM
    JURKOWSKI, J
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1990, 33 (04) : 802 - 805
  • [9] Segmented high-purity germanium detectors
    Yu. B. Gurov
    K. N. Gusev
    S. L. Katulina
    V. G. Sandukovsky
    D. Borowicz
    J. Yurkowski
    Instruments and Experimental Techniques, 2007, 50 : 757 - 760
  • [10] ENCAPSULATION OF HIGH-PURITY GERMANIUM DETECTORS
    ARMANTRO.GA
    WICHNER, R
    SWIERKOW.SP
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) : 344 - 346