Detailing the use of magnetohydrodynamic effects for synchronization of MRI with the cardiac cycle: A feasibility study

被引:20
作者
Frauenrath, Tobias [1 ]
Fuchs, Katharina [1 ]
Dieringer, Matthias A. [1 ,2 ]
Oezerdem, Celal [1 ]
Patel, Nishant [1 ]
Renz, Wolfgang [1 ,3 ]
Greiser, Andreas [3 ]
Elgeti, Thomas [4 ]
Niendorf, Thoralf [1 ,5 ]
机构
[1] Max Delbruck Ctr Mol Med, BUFF, D-13125 Berlin, Germany
[2] Charite, Working Grp Cardiovasc Magnet Resonance, D-13353 Berlin, Germany
[3] Siemens Healthcare, Erlangen, Germany
[4] Charite, Dept Radiol, D-13353 Berlin, Germany
[5] Humboldt Univ, Expt & Clin Res Ctr, D-10099 Berlin, Germany
关键词
high field MRI; cardiac gating; magnetohydrodynamic effect; cardiovascular MRI; GATED MAGNETIC-RESONANCE; CINE MRI; 7; TESLA; ANGIOGRAPHY; FIELD; INVERSION; HUMANS;
D O I
10.1002/jmri.23634
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the feasibility of using magnetohydrodynamic (MHD) effects for synchronization of magnetic resonance imaging (MRI) with the cardiac cycle. Materials and Methods: The MHD effect was scrutinized using a pulsatile flow phantom at B0 = 7.0 T. MHD effects were examined in vivo in healthy volunteers (n = 10) for B0 ranging from 0.057.0 T. Noncontrast-enhanced MR angiography (MRA) of the carotids was performed using a gated steady-state free-precession (SSFP) imaging technique in conjunction with electrocardiogram (ECG) and MHD synchronization. Results: The MHD potential correlates with flow velocities derived from phase contrast MRI. MHD voltages depend on the orientation between B0 and the flow of a conductive fluid. An increase in the interelectrode spacing along the flow increases the MHD potential. In vivo measurement of the MHD effect provides peak voltages of 1.5 mV for surface areas close to the common carotid artery at B0 = 7.0 T. Synchronization of MRI with the cardiac cycle using MHD triggering is feasible. MHD triggered MRA of the carotids at 3.0 T showed an overall image quality and richness of anatomic detail, which is comparable to ECG-triggered MRAs. Conclusion: This feasibility study demonstrates the use of MHD effects for synchronization of MR acquisitions with the cardiac cycle. J. Magn. Reson. Imaging 2012;36:364372. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:364 / 372
页数:9
相关论文
共 27 条
  • [1] Alterations in human ECG due to the MagnetoHydroDynamic effect: A method for accurate R peak detection in the presence of high MHD artifacts
    Abi-Abdallah, Dima
    Robin, Vincent
    Drochon, Agnes
    Fokapu, Odette
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1842 - +
  • [2] Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T
    Becker, Meike
    Frauenrath, Tobias
    Hezel, Fabian
    Krombach, Gabriele A.
    Kremer, Ute
    Koppers, Benedikt
    Butenweg, Christoph
    Goemmel, Andreas
    Utting, Jane F.
    Schulz-Menger, Jeanette
    Niendorf, Thoralf
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (06) : 1344 - 1355
  • [3] Quantitative Assessment of Left Ventricular Function in Humans at 7 T
    Brandts, Anne
    Westenberg, Jos J. M.
    Versluis, Maarten J.
    Kroft, Lucia J. M.
    Smith, Nadine B.
    Webb, Andrew G.
    de Roos, Albert
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (05) : 1472 - 1478
  • [4] OPTIMIZING ELECTROCARDIOGRAPH ELECTRODE PLACEMENT FOR CARDIAC-GATED MAGNETIC-RESONANCE-IMAGING
    DIMICK, RN
    HEDLUND, LW
    HERFKENS, RJ
    FRAM, EK
    UTZ, J
    [J]. INVESTIGATIVE RADIOLOGY, 1987, 22 (01) : 17 - 22
  • [5] Magnetic resonance angiography of the carotid arteries using three different techniques: Accuracy compared with intraarterial X-ray angiography and endarterectomy specimens
    Fellner, C
    Lang, W
    Janka, R
    Wutke, R
    Bautz, W
    Fellner, FA
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) : 424 - 431
  • [6] Fischer SE, 1999, MAGN RESON MED, V42, P361, DOI 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO
  • [7] 2-9
  • [8] Acoustic method for synchronization of magnetic resonance imaging (MRI)
    Frauenrath, Tobias
    Niendorf, Thoralf
    Kob, Malte
    [J]. ACTA ACUSTICA UNITED WITH ACUSTICA, 2008, 94 (01) : 148 - 155
  • [9] Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla
    Frauenrath, Tobias
    Hezel, Fabian
    Renz, Wolfgang
    d'Orth, Thibaut de Geyer
    Dieringer, Matthias
    von Knobelsdorff-Brenkenhoff, Florian
    Prothmann, Marcel
    Schulz-Menger, Jeanette
    Niendorf, Thoralf
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2010, 12
  • [10] Feasibility of Cardiac Gating Free of Interference With Electro-Magnetic Fields at 1.5 Tesla, 3.0 Tesla and 7.0 Tesla Using an MR-Stethoscope
    Frauenrath, Tobias
    Hezel, Fabian
    Heinrichs, Uwe
    Kozerke, Sebastian
    Utting, Jane F.
    Kob, Malte
    Butenweg, Christoph
    Boesiger, Peter
    Niendorf, Thoralf
    [J]. INVESTIGATIVE RADIOLOGY, 2009, 44 (09) : 539 - 547