Effect of electron beam radio sterilization on cyclic olefin copolymers used as pharmaceutical storage materials

被引:14
作者
Barakat, Hala [1 ,2 ]
Aymes-Chodur, Caroline [1 ]
Saunier, Johanna [1 ]
Yagoubi, Najet [1 ]
机构
[1] Univ Paris 11, Fac Pharm, IFR 141, Lab Mat & Sante EA 401, F-92296 Chatenay Malabry, France
[2] Tishreen Univ, Fac Pharm, Qual Control Dept, Latakia, Syria
关键词
COC; Electron beam radio-sterilization; Crosslinking; Low molecular weight compounds; Surface modification; Ageing; CHROMATOGRAPHY-MASS-SPECTROMETRY; SURFACE MODIFICATION; RADIATION; POLYPROPYLENE; PRODUCTS; POLYMERS; PLASMA; POLYETHYLENE; IRRADIATION; TRANSITION;
D O I
10.1016/j.radphyschem.2012.05.006
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The aim of this work was to study the effect of radio-sterilization on cyclo olefin copolymers (COC), that can be used as pharmaceutical storage materials, both on the surface and in the volume of the material, and to investigate the impact of the presence of a lubricant. A cyclo olefin copolymer (TOPAS (R) 8007) was treated with an electron beam radio-sterilization at different doses ranging from 25 to 150 kGy. Polymer structure and bulk properties were evaluated by Fourier Transform Infrared Spectroscopy (FTIR), Differential Scanning Calorimetry (DSC) and Size Exclusion Chromatography (SEC). A good correlation between those analytical techniques was observed: oxidation products were formed and crosslinking of chains occured. Although these modifications were important, the effect on the thermal properties was weak. The analysis by Reversed Phase High Performance Liquid Chromatography (RP-HPLC) of extraction's solutions of COC after irradiation showed both a remarkable decrease of the extractable amount of polyphenolic antioxidant (Irganox 1010 (R)) initially present in the matrix, and a generation of an important number of degradation products that represent potential migrants for pharmaceutical formulations. Surface modifications were evidenced by both (FTIR/ATR) and contact angle measurements of COC films. An increase in surface polarity of COC after radio-sterilization was observed. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:223 / 231
页数:9
相关论文
共 37 条
[1]  
Abraham A.C., RAD PHYS CHEM, V79, P83
[2]  
ALLEN DW, 1991, RADIAT PHYS CHEM, V38, P461
[3]   CHARACTERIZATION OF ELECTRON-BEAM GENERATED TRANSFORMATION PRODUCTS OF IRGANOX-1010 BY PARTICLE-BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY WITH ONLINE DIODE-ARRAY DETECTION [J].
ALLEN, DW ;
CLENCH, MR ;
CROWSON, A ;
LEATHARD, DA ;
SAKLATVALA, R .
JOURNAL OF CHROMATOGRAPHY A, 1994, 679 (02) :285-297
[4]  
Ansari MIA, 2003, FOOD BIOPROD PROCESS, V81, P57, DOI 10.1205/096030803765208670
[5]   Mechanical and chemical analysis of plasma and ultraviolet-ozone surface treatments for thermal bonding of polymeric microfluidic devices [J].
Bhattacharyya, Arpita ;
Klapperich, Catherine M. .
LAB ON A CHIP, 2007, 7 (07) :876-882
[6]  
Bourges F., 1992, PACKAGING TECHNOLOGY, V5, P205, DOI 10.1002/pts.2770050406
[7]  
Bourges F., 1992, Packaging Technology and Science, V5, P197, DOI [10.1002/pts.2770050405, DOI 10.1002/PTS.2770050405]
[8]   Characterization of gamma-irradiated polyethylene terephthalate by liquid-chromatography-mass-spectrometry (LC-MS) with atmospheric-pressure chemical ionization (APCI) [J].
Buchalla, R ;
Begley, TH .
RADIATION PHYSICS AND CHEMISTRY, 2006, 75 (01) :129-137
[9]   Characterization of volatile radiolysis products in radiation-sterilized plastics by thermal desorption-gas chromatography-mass spectrometry:: screening of six medical polymers [J].
Buchalla, R ;
Boess, C ;
Bögl, KW .
RADIATION PHYSICS AND CHEMISTRY, 1999, 56 (03) :353-367
[10]   Tuning of surface properties of thin polymer films by electron beam treatment [J].
Burkert, Sina ;
Kuntzsch, Marco ;
Bellmann, Cornelia ;
Uhlmann, Petra ;
Stamm, Manfred .
APPLIED SURFACE SCIENCE, 2009, 255 (12) :6256-6261