Correlation between estimates of tumor perfusion from microbubble contrast-enhanced sonography and dynamic contrast-enhanced magnetic resonance imaging

被引:28
|
作者
Yankeelov, TE
Niermann, KJ
Huamani, J
Kim, DW
Quarles, CC
Fleischer, AC
Hallahan, DE
Price, RR
Gore, JC
机构
[1] Vanderbilt Univ, Med Ctr, Inst Imaging Sci, Med Ctr N R1302, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Radiol, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Radiol Sci, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Dept Radiat Oncol, Nashville, TN 37232 USA
[5] Vanderbilt Univ, Dept Obstet & Gynecol, Nashville, TN 37232 USA
关键词
dynamic contrast-enhanced; magnetic resonance imaging; microbubble contrast-enhanced sonography; microbubbles; tumor;
D O I
10.7863/jum.2006.25.4.487
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. We compared measurements of tumor perfusion from microbubble contrast-enhanced sonography (MCES) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in an animal tumor model. Methods. Seven mice were implanted with Lewis lung carcinoma cells on their hind limbs and imaged 14 days later with a Philips 5- to 7-MHz sonography system (Philips Medical Systems, Andover, MA) and a Varian 7.0-T MRI system (Varian, Inc, Palo Alto, CA). For sonographic imaging 100 mu L of a perfluoropropane microbubble contrast agent (Definity; Bristol-Myers Squibb Medical Imaging, Billerica, MA) was injected and allowed to reach a pseudo steady state, after which a high-mechanical index pulse was delivered to destroy the microbubbles within the field of view, and the replenishment of the microbubbles was imaged for 30 to 60 seconds. The MRI included acquisition of a T, map and 35 serial T-1-weighted images (repetition time, 100 milliseconds; echo time, 3.1 milliseconds; alpha, 30 degrees) after the injection of 100 mu L of 0.2-mmol/kg gadopentetate dimeglumine (Magnevist; Berlex, Wayne, NJ). Region-of-interest and voxel-by-voxel analyses of both data sets were performed; microbubble contrast-enhanced sonography returned estimates of microvessel cross-sectional area, microbubble velocity, and mean blood flow, whereas DCE-MRI returned estimates of a perfusion-permeability index and the extravascular extracellular volume fraction. Results. Comparing similar regions of tumor tissue seen on sonography and MRI, region-of-interest analyses revealed a strong (r(2) = 0.57) and significant relationship (P < .002) between the estimates of perfusion obtained by the two modalities. Conclusions. Microbubble contrast-enhanced sonography can effectively depict intratumoral heterogeneity in preclinical xenograft models when voxel-by-voxel analysis is performed, and this analysis correlates with similar DCE-MRI measurements.
引用
收藏
页码:487 / 497
页数:11
相关论文
共 50 条
  • [21] Contrast-enhanced sonography in the characterization of small hepatocellular carcinomas in cirrhotic patients: Comparison with contrast-enhanced ultrafast magnetic resonance imaging
    Giorgio, A
    Ferraioli, G
    de Stefano, G
    Coppola, C
    Di Sarno, A
    Del Viscovo, L
    JOURNAL OF HEPATOLOGY, 2005, 42 : 93 - 94
  • [22] Vascularity and Dynamic Contrast-Enhanced Breast Magnetic Resonance Imaging
    Frankhouser, David E.
    Dietze, Eric
    Mahabal, Ashish
    Seewaldt, Victoria L.
    FRONTIERS IN RADIOLOGY, 2021, 1
  • [23] Dynamic Contrast-enhanced Magnetic Resonance Imaging: Applications in Oncology
    Teo, Q. Q.
    Thng, C. H.
    Koh, T. S.
    Ng, Q. S. p
    CLINICAL ONCOLOGY, 2014, 26 (10) : E9 - E20
  • [24] Contrast-enhanced sonography
    van de Sandt, M
    Deichert, U
    HUMAN REPRODUCTION, 1998, 13 (11) : 3282 - 3282
  • [25] Dynamic contrast-enhanced magnetic resonance imaging of the sarcopenic muscle
    Nicolato E.
    Farace P.
    Asperio R.M.
    Marzola P.
    Lunati E.
    Sbarbati A.
    Osculati F.
    BMC Medical Imaging, 2 (1)
  • [26] Information Criteria for Dynamic Contrast-Enhanced Magnetic Resonance Imaging
    Shinohara, Russell T.
    Crainiceanu, Ciprian S.
    Caffo, Brian S.
    Reich, Daniel S.
    2013 3RD INTERNATIONAL WORKSHOP ON PATTERN RECOGNITION IN NEUROIMAGING (PRNI 2013), 2013, : 37 - 41
  • [27] Dynamic contrast-enhanced magnetic resonance lymphangiography
    Karen I. Ramirez-Suarez
    Luis O. Tierradentro-Garcia
    Christopher L. Smith
    Ganesh Krishnamurthy
    Fernando A. Escobar
    Hansel J. Otero
    Jordan B. Rapp
    Yoav Dori
    David M. Biko
    Pediatric Radiology, 2022, 52 : 285 - 294
  • [28] The comparison between contrast-enhanced ultrasound and contrast-enhanced magnetic resonance imaging in diagnosing bladder urothelial carcinoma
    Fu, Wenyu
    Liu, Dan
    Xiong, Yongjiang
    Liu, Chuan
    Liu, Jiaji
    Yi, Xinping
    Zhao, Tao
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2023, 55 (05) : 1073 - 1079
  • [29] The comparison between contrast-enhanced ultrasound and contrast-enhanced magnetic resonance imaging in diagnosing bladder urothelial carcinoma
    Wenyu Fu
    Dan Liu
    Yongjiang Xiong
    Chuan Liu
    Jiaji Liu
    Xinping Yi
    Tao Zhao
    International Urology and Nephrology, 2023, 55 : 1073 - 1079
  • [30] Contrast-enhanced magnetic resonance imaging of the breast
    Helbich, TH
    EUROPEAN JOURNAL OF RADIOLOGY, 2000, 34 (03) : 208 - 219