Statistical diagnosis of a gas-solid fluidized bed using Electrical Capacitance Tomography

被引:19
|
作者
Rautenbach, Christo
Melaaen, Morten C.
Halvorsen, Britt M.
机构
[1] Institute for Process, Energy and Environmental Technology, Telemark University College
关键词
ECT; Gas-solid fluidization; Particle size distribution; Fluidization quality; Skewness; Excess kurtosis; QUALITY;
D O I
10.1016/j.ijmultiphaseflow.2012.10.002
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Fluidization experiments were performed using several particle size distributions of spherical glass particles, ranging from Geldart B to D. An Electrical Capacitance Tomography (ECT) tomograph was utilized in the present study and its usefulness as a diagnostic tool is illustrated. During the experiments a 10.4 cm diameter column was utilized and the column was operated at atmospheric pressure and room temperature (cold fluidized bed). Statistical analyses were performed on the average solid fraction data obtained using the ECT tomograph. Using the time domain skewness and kurtosis the time series could be characterised and the quality of fluidization is determined at different superficial gas velocities (Azizpour, H., Sotudeh-Gharebagh, It, Zarghami, R., Abbasi, M., Mostoufi, N., Mahjoob, M., 2011. Characterization of gas-solid fluidized bed hydrodynamics by vibration signal analysis. International journal of Multiphase Flow, 37, 788-793). Statistical analysis is also used to characterise the influence of small particles on the bed hydrodynamics. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 50 条
  • [1] Application of electrical capacitance tomography for gas-solid fluidized bed measurement
    Ye, M. (maoye@dicp.ac.cn), 1600, Materials China (65):
  • [2] Velocity Profiling of a Gas-Solid Fluidized Bed Using Electrical Capacitance Volume Tomography
    Park, Cody
    Chowdhury, Shah M.
    Pottimurthy, Yaswanth
    Marashdeh, Qussai M.
    Tong, Andrew
    Teixeira, Fernando L.
    Fan, Liang-Shih
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [3] On parameter measurement of gas-solid fluidized bed based on electrical capacitance tomography
    Wang Lei
    Shen Tao
    Proceedings of 2005 Chinese Control and Decision Conference, Vols 1 and 2, 2005, : 591 - 593
  • [4] Electrical capacitance tomography imaging of gas-solid and gas-liquid-solid fluidized bed systems
    Fan, LS
    Warsito, W
    Du, B
    JOURNAL OF VISUALIZATION, 2004, 7 (01) : 5 - 5
  • [5] Electrical capacitance tomography imaging of gas-solid and gas-liquid-solid fluidized bed systems
    L. -S. Fan
    W. Warsito
    B. Du.
    Journal of Visualization, 2004, 7 : 5 - 5
  • [6] Study on the relation of bubble behavior and bed density in gas-solid separation fluidized bed using electrical capacitance tomography
    Wang, Dan
    Wang, Cheng
    Chen, Zengqiang
    Duan, Chenlong
    Zhou, Chenyang
    PARTICULATE SCIENCE AND TECHNOLOGY, 2024, 42 (04) : 553 - 564
  • [7] Effect of Electrode Length of an Electrical Capacitance Tomography Sensor on Gas-Solid Fluidized Bed Measurements
    Huang, Kai
    Meng, Shuanghe
    Guo, Qiang
    Yang, Wuqiang
    Zhang, Tao
    Ye, Mao
    Liu, Zhongmin
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2019, 58 (47) : 21827 - 21841
  • [8] Investigation of wetting and drying process in a gas-solid fluidized bed by electrical capacitance tomography and pressure measurement
    Zhang, J. L.
    Mao, M. X.
    Ye, J. M.
    Wang, H. G.
    Yang, W. Q.
    POWDER TECHNOLOGY, 2016, 301 : 1148 - 1158
  • [9] Efficient super-resolution image reconstruction of electrical capacitance tomography for gas-solid fluidized bed measurement
    Li, Jian
    Wang, Ying
    Tang, Zheng
    Zhang, Biao
    Xu, Chuanlong
    CHEMICAL ENGINEERING SCIENCE, 2024, 291
  • [10] Dynamic voidage measurements in a gas solid fluidized bed by electrical capacitance tomography
    Huang, ZY
    Wang, BL
    Li, HQ
    CHEMICAL ENGINEERING COMMUNICATIONS, 2003, 190 (10) : 1395 - 1410