Dual layer dol detector modules for a dedicated mouse brain PET/MRI

被引:4
作者
Parl, C. [1 ]
Kolb, A. [1 ]
Stricker-Shaver, D. [1 ]
Pichler, B. J. [1 ]
机构
[1] Eberhard Karls Univ Tuebingen, Werner Siemens Imaging Ctr, Dept Preclin Imaging & Radiopharm, Roentgenweg 13, D-72076 Tubingen, Germany
关键词
depth of interaction; PET/MRI; small animal brain imaging; preclinical imaging; brain; PET; HIGH-RESOLUTION PET; POSITRON RANGE; RESTING-STATE; ENERGY-LEVELS; MONTE-CARLO; PERFORMANCE; SYSTEM; MRI; DEPTH; SCANNER;
D O I
10.1088/1361-6560/aaff73
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The outcome of preclinical imaging studies are enhanced by simultaneous, high-resolution anatomical and molecular data, which advanced PET/MRI systems provide. Nevertheless, mapping of neuroreceptors and accurate quantification of PET tracer distribution in mouse brains is not trivial. The restricted spatial resolution and sensitivity in commercial animal PET systems limits the image quality and the quantification accuracy. We are currently developing a PET/MRI system dedicated for mouse brain studies. The PET system will offer system dimensions of approx. 30 mm in diameter and an axial length of more than 38 mm. This work discusses two system geometries including their associated block detectors. Both configurations were based on a dual layer offset structure with small crystals sizes, in the order of 1 x 1 x 4/6 mm(3), to provide discrete depth of interaction information. The detector for configuration 'A' was based on a 4 x 4 silicon photomultiplier (SiPM) array attached to an optical diffusor, and a 12 x 12 as well as a 9 x 11 LSO crystal array, to achieve optimal system sensitivity. This configuration was evaluated by a double layer of 12 x 12 crystals. Configuration 'B' was composed of three 2 x 2 SiPM arrays equipped with a 1 mm diffusor to read out an LSO stack of 20 x 6 and 19 x 5 individual crystals. The average peak-to-valley ratio of the inner/outer layer was 3.5/3.6 for detector 'A', and 3.4/2.8 for detector 'W. The average full width at half maximum (FWHM) energy resolution of the block detectors were 22.24% +/- 3.36% for 'A' and 30.67% +/- 5.37% for 'W. The FWHM of the full block timing resolution of the inner/outer layer was 1.4 ns/1.2 ns for detector 'A' and 1.8 ns/1.4 ns for 'B'. The performance of the crystal position profile, the energy, and timing resolution indicate that configuration 'A' is more appropriate for a mouse brain PET/MRI system.
引用
收藏
页数:16
相关论文
共 66 条
  • [1] ENERGY-LEVELS OF LIGHT-NUCLEI A=13-15
    AJZENBERGSELOVE, F
    [J]. NUCLEAR PHYSICS A, 1991, 523 (01) : 1 - 196
  • [2] SCINTILLATION CAMERA
    ANGER, HO
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1958, 29 (01) : 27 - 33
  • [3] PET/MR Imaging and Optical Imaging of Metastatic Rhabdomyosarcoma in Mice
    Armeanu-Ebinger, Sorin
    Griessinger, Christoph M.
    Herrmann, Delia
    Fuchs, Joerg
    Kneilling, Manfred
    Pichler, Bernd J.
    Seitz, Guido
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (09) : 1545 - 1551
  • [4] A MULTICRYSTAL 2-DIMENSIONAL BGO DETECTOR SYSTEM FOR POSITRON EMISSION TOMOGRAPHY
    CASEY, ME
    NUTT, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 460 - 463
  • [5] Characterization of dual layer phoswich detector performance for small animal PET using Monte Carlo simulation
    Chung, YH
    Choi, Y
    Cho, G
    Choe, YS
    Lee, KH
    Kim, BT
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (13) : 2881 - 2890
  • [6] Performance evaluation of an Inveon PET preclinical scanner
    Constantinescu, Cristian C.
    Mukherjee, Jogeshwar
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) : 2885 - 2899
  • [7] Principles of PET/MR Imaging
    Disselhorst, Jonathan A.
    Bezrukov, Ilja
    Kolb, Armin
    Parl, Christoph
    Pichler, Bernd J.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55 : 2S - 10S
  • [8] Noninvasive Nuclear Imaging Enables the In Vivo Quantification of Striatal Dopamine Receptor Expression and Raclopride Affinity in Mice
    Fischer, Kristina
    Sossi, Vesna
    Schmid, Andreas
    Thunemann, Martin
    Maier, Florian C.
    Judenhofer, Martin S.
    Mannheim, Julia G.
    Reischl, Gerald
    Pichler, Bernd J.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (07) : 1133 - 1141
  • [9] Design and Performance of a Resistor Multiplexing Readout Circuit for a SiPM Detector
    Goertzen, Andrew L.
    Zhang, Xuezhu
    McClarty, Megan M.
    Berg, Eric J.
    Liu, Chen-Yi
    Kozlowski, Piotr
    Retiere, Fabrice
    Ryner, Lawrence
    Sossi, Vesna
    Stortz, Greg
    Thompson, Christopher J.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (03) : 1541 - 1549
  • [10] 64Cu antibody-targeting of the T-cell receptor and subsequent internalization enables in vivo tracking of lymphocytes by PET
    Griessinger, Christoph M.
    Maurer, Andreas
    Kesenheimer, Christian
    Kehlbach, Rainer
    Reischl, Gerald
    Ehrlichmann, Walter
    Bukala, Daniel
    Harant, Maren
    Cay, Funda
    Brueck, Juergen
    Nordin, Renate
    Kohlhofer, Ursula
    Rammensee, Hans-Georg
    Quintanilla-Martinez, Leticia
    Schaller, Martin
    Roecken, Martin
    Pichler, Bernd J.
    Kneilling, Manfred
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2015, 112 (04) : 1161 - 1166