Range optimization for mono- and bi-energetic proton modulated arc therapy with pencil beam scanning

被引:25
|
作者
Sanchez-Parcerisa, Daniel [1 ,2 ]
Kirk, Maura [1 ]
Fager, Marcus [1 ]
Burgdorf, Brendan [1 ]
Stowe, Malorie [1 ]
Solberg, Tim [1 ]
Carabe, Alejandro [1 ]
机构
[1] Hosp Univ Penn, Dept Radiat Oncol, 3400 Civ Ctr Bvd, Philadelphia, PA 19104 USA
[2] Univ Complutense Madrid, Dept Fis Atom Mol & Nucl, Fac Ciencias Fis, Ave Complutense S-N, E-28040 Madrid, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 21期
关键词
protontherapy; pencil beam scanning; arc therapy; RELATIVE BIOLOGICAL EFFECTIVENESS; ROBUST OPTIMIZATION; RADIOTHERAPY; PROSTATE; BRAIN; MODEL;
D O I
10.1088/0031-9155/61/21/N565
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The development of rotational proton therapy plans based on a pencil-beam-scanning (PBS) system has been limited, among several other factors, by the energy-switching time between layers, a system-dependent parameter that ranges between a fraction of a second and several seconds. We are investigating mono-and bi-energetic rotational proton modulated arc therapy (PMAT) solutions that would not be affected by long energy switching times. In this context, a systematic selection of the optimal proton energy for each arc is vital. We present a treatment planning comparison of four different range selection methods, analyzing the dosimetric outcomes of the resulting treatment plans created with the ranges obtained. Given the patient geometry and arc definition (gantry and couch trajectories, snout elevation) our in-house treatment planning system (TPS) FoCa was used to find the maximum, medial and minimum water-equivalent thicknesses (WETs) of the target viewed from all possible field orientations. Optimal ranges were subsequently determined using four methods: (1) by dividing the max/ min WET interval into equal steps, (2) by taking the average target midpoints from each field, (3) by taking the average WET of all voxels from all field orientations, and (4) by minimizing the fraction of the target which cannot be reached from any of the available angles. After the range (for mono-energetic plans) or ranges (for bi-energetic plans) were selected, the commercial clinical TPS in use in our institution (Varian Eclipse T) was used to produce the PMAT plans using multifield optimization. Linear energy transfer (LET) distributions of all plans were also calculated using FoCa and compared among the different methods. Mono- and bi-energetic PMAT plans, composed of a single 180 degrees arc, were created for two patient geometries: a C-shaped target located in the mediastinal area of a thoracic tissue-equivalent phantom and a small brain tumor located directly above the brainstem. All plans were optimized using the same procedure to (1) achieve target coverage, (2) reduce dose to OAR and (3) limit dose hot spots in the target. Final outcomes were compared in terms of the resulting dose and LET distributions. Data shows little significant differences among the four studied methods, with superior results obtained with mono-energetic plans. A streamlined systematic method has been implemented in an in-house TPS to find the optimal range to maximize target coverage with rotational mono-or bi-energetic PBS rotational plans by minimizing the fraction of the target that cannot be reached by any direction.
引用
收藏
页码:N565 / N574
页数:10
相关论文
共 50 条
  • [31] Pencil Beam Scanning Proton Therapy for Paediatric Neuroblastoma with Motion Mitigation Strategy for Moving Target Volumes
    Lim, P. S.
    Pica, A.
    Hrbacek, J.
    Bachtiary, B.
    Walser, M.
    Lomax, A. J.
    Weber, D. C.
    CLINICAL ONCOLOGY, 2020, 32 (07) : 467 - 476
  • [32] Experimental validation of a 4D dose calculation routine for pencil beam scanning proton therapy
    Pfeiler, Tina
    Baeumer, Christian
    Engwall, Erik
    Geismar, Dirk
    Spaan, Bernhard
    Timmermann, Beate
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (02): : 121 - 133
  • [33] Evaluation of the ray-casting analytical algorithm for pencil beam scanning proton therapy
    Winterhalter, Carla
    Zepter, Stefan
    Shim, Sojin
    Meier, Gabriel
    Bolsi, Alessandra
    Fredh, Anna
    Hrbacek, Jan
    Oxley, David
    Zhang, Ye
    Weber, Damien C.
    Lomax, Antony
    Safai, Sairos
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (06):
  • [34] Performance of a scintillation imaging system for relative dosimetry in pencil beam scanning proton therapy
    Liu, Qi
    Gong, Liangde
    Li, Xiufang
    Grossmann, Martin
    Wang, Jie
    Guo, Mengya
    Gu, Shuaizhe
    Lin, Ye
    Zhang, Manzhou
    Pu, Yuehu
    Chen, Zhiling
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1040
  • [35] Robustness evaluation of pencil beam scanning proton therapy treatment planning: A systematic review
    Sterpin, E.
    Widesott, L.
    Poels, K.
    Hoogeman, M.
    Korevaar, E. W.
    Lowe, M.
    Molinelli, S.
    Fracchiolla, F.
    RADIOTHERAPY AND ONCOLOGY, 2024, 197
  • [36] Clinical Outcome of Sacral Chordoma Patients Treated with Pencil Beam Scanning Proton Therapy
    Walser, M.
    Bojaxhiu, B.
    Kawashiro, S.
    Tran, S.
    Beer, J.
    Leiser, D.
    Pica, A.
    Bachtiary, B.
    Weber, D. C.
    CLINICAL ONCOLOGY, 2021, 33 (12) : E578 - E585
  • [37] The LET enhancement of energy-specific collimation in pencil beam scanning proton therapy
    Smith, Blake R.
    Hyer, Daniel E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (01):
  • [38] Log file based Monte Carlo calculations for proton pencil beam scanning therapy
    Winterhalter, Carla
    Meier, Gabriel
    Oxley, David
    Weber, Damien C.
    Lomax, Antony J.
    Safai, Sairos
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (03):
  • [39] Online Adaptive Proton Therapy Facilitated by Artificial Intelligence-Based Autosegmentation in Pencil Beam Scanning Proton Therapy
    Feng, Hongying
    Shan, Jie
    Vargas, Carlos E.
    Keole, Sameer R.
    Rwigema, Jean-Claude M.
    Yu, Nathan Y.
    Ding, Yuzhen
    Zhang, Lian
    Hu, Yanle
    Schild, Steven E.
    Wong, William W.
    Vora, Sujay A.
    Shen, Jiajian
    Liu, Wei
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2025, 121 (03): : 822 - 831
  • [40] Detectors for quality assurance of pencil beam scanning gantries for proton therapy
    Gagnon-Moisan, F.
    van der Meer, R.
    Chowdhuri, Z.
    Eichin, M.
    Koenig, S.
    Schmid, F. -J.
    Weber, D. C.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S44 - S45