Range optimization for mono- and bi-energetic proton modulated arc therapy with pencil beam scanning

被引:25
|
作者
Sanchez-Parcerisa, Daniel [1 ,2 ]
Kirk, Maura [1 ]
Fager, Marcus [1 ]
Burgdorf, Brendan [1 ]
Stowe, Malorie [1 ]
Solberg, Tim [1 ]
Carabe, Alejandro [1 ]
机构
[1] Hosp Univ Penn, Dept Radiat Oncol, 3400 Civ Ctr Bvd, Philadelphia, PA 19104 USA
[2] Univ Complutense Madrid, Dept Fis Atom Mol & Nucl, Fac Ciencias Fis, Ave Complutense S-N, E-28040 Madrid, Spain
关键词
protontherapy; pencil beam scanning; arc therapy; RELATIVE BIOLOGICAL EFFECTIVENESS; ROBUST OPTIMIZATION; RADIOTHERAPY; PROSTATE; BRAIN; MODEL;
D O I
10.1088/0031-9155/61/21/N565
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The development of rotational proton therapy plans based on a pencil-beam-scanning (PBS) system has been limited, among several other factors, by the energy-switching time between layers, a system-dependent parameter that ranges between a fraction of a second and several seconds. We are investigating mono-and bi-energetic rotational proton modulated arc therapy (PMAT) solutions that would not be affected by long energy switching times. In this context, a systematic selection of the optimal proton energy for each arc is vital. We present a treatment planning comparison of four different range selection methods, analyzing the dosimetric outcomes of the resulting treatment plans created with the ranges obtained. Given the patient geometry and arc definition (gantry and couch trajectories, snout elevation) our in-house treatment planning system (TPS) FoCa was used to find the maximum, medial and minimum water-equivalent thicknesses (WETs) of the target viewed from all possible field orientations. Optimal ranges were subsequently determined using four methods: (1) by dividing the max/ min WET interval into equal steps, (2) by taking the average target midpoints from each field, (3) by taking the average WET of all voxels from all field orientations, and (4) by minimizing the fraction of the target which cannot be reached from any of the available angles. After the range (for mono-energetic plans) or ranges (for bi-energetic plans) were selected, the commercial clinical TPS in use in our institution (Varian Eclipse T) was used to produce the PMAT plans using multifield optimization. Linear energy transfer (LET) distributions of all plans were also calculated using FoCa and compared among the different methods. Mono- and bi-energetic PMAT plans, composed of a single 180 degrees arc, were created for two patient geometries: a C-shaped target located in the mediastinal area of a thoracic tissue-equivalent phantom and a small brain tumor located directly above the brainstem. All plans were optimized using the same procedure to (1) achieve target coverage, (2) reduce dose to OAR and (3) limit dose hot spots in the target. Final outcomes were compared in terms of the resulting dose and LET distributions. Data shows little significant differences among the four studied methods, with superior results obtained with mono-energetic plans. A streamlined systematic method has been implemented in an in-house TPS to find the optimal range to maximize target coverage with rotational mono-or bi-energetic PBS rotational plans by minimizing the fraction of the target that cannot be reached by any direction.
引用
收藏
页码:N565 / N574
页数:10
相关论文
共 50 条
  • [1] Comparison of dosimetries of carbon-ion pencil beam scanning, proton pencil beam scanning and volumetric modulated arc therapy for locally recurrent rectal cancer
    Mori, Shinichiro
    Bhattacharyya, Tapesh
    Furuichi, Wataru
    Tohyama, Naoki
    Nomoto, Akihiro
    Shinoto, Makoto
    Takiyama, Hirotoshi
    Yamada, Shigeru
    JOURNAL OF RADIATION RESEARCH, 2023, 64 (01) : 162 - 170
  • [2] Gantry-based pencil beam scanning proton therapy for uveal melanoma: IMPT versus proton arc therapy
    Qi, Hang
    Hu, Lei
    Huang, Sheng
    Lee, Yen-Po
    Yu, Francis
    Chen, Qing
    Yang, Yunjie
    Kang, Minglei
    Zhai, Huifang
    Vermeulen, Milo
    Shim, Andy
    Park, Peter
    Ding, Xuanfeng
    Zhou, Jun
    Abramson, David H.
    Francis, Jasmine H.
    Simone, Charles B.
    Barker, Christopher A.
    Lin, Haibo
    RADIATION ONCOLOGY, 2025, 20 (01)
  • [3] Dosimetric comparison of pencil beam scanning proton therapy with or without multi-leaf collimator versus volumetric-modulated arc therapy for treatment of malignant glioma
    Miyata, Junya
    Tominaga, Yuki
    Kondo, Kazuto
    Sonoda, Yasuaki
    Hanazawa, Hideki
    Sakai, Mami
    Itasaka, Satoshi
    Oita, Masataka
    Kuroda, Masahiro
    MEDICAL DOSIMETRY, 2023, 48 (02) : 105 - 112
  • [4] Contour scanning for penumbra improvement in pencil beam scanned proton therapy
    Meier, G.
    Leiser, D.
    Besson, R.
    Mayor, A.
    Safai, S.
    Weber, D. C.
    Lomax, A. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (06) : 2398 - 2416
  • [5] Impact of dose engine algorithm in pencil beam scanning proton therapy for breast cancer
    Tommasino, Francesco
    Fellin, Francesco
    Lorentini, Stefano
    Farace, Paolo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 50 : 7 - 12
  • [6] A pre-absorber optimization technique for pencil beam scanning proton therapy treatments
    Fracchiolla, Francesco
    Fellin, Francesco
    Innocenzi, Marta
    Lipparini, Mirko
    Lorentini, Stefano
    Widesott, Lamberto
    Farace, Paolo
    Schwarz, Marco
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 : 145 - 152
  • [7] A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams
    Charlwood, Frances C.
    Aitkenhead, Adam H.
    Mackay, Ranald I.
    MEDICAL PHYSICS, 2016, 43 (03) : 1462 - 1472
  • [8] Biophysical characterization of collimated and uncollimated fields in pencil beam scanning proton therapy
    Nabha, Racell
    De Saint-Hubert, Marijke
    Marichal, Joachim
    Esser, Johannes
    Van Hoey, Olivier
    Baeumer, Christian
    Verbeek, Nico
    Struelens, Lara
    Sterpin, Edmond
    Tabury, Kevin
    Marek, Lukas
    Granja, Carlos
    Timmermann, Beate
    Vanhavere, Filip
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (06)
  • [9] Experimental fluence-modulated proton computed tomography by pencil beam scanning
    Dedes, George
    Johnson, Robert P.
    Pankuch, Mark
    Detrich, Nick
    Pols, Willemijn M. A.
    Rit, Simon
    Schulte, Reinhard W.
    Parodi, Katia
    Landry, Guillaume
    MEDICAL PHYSICS, 2018, 45 (07) : 3287 - 3296
  • [10] Secondary neutron dose contribution from pencil beam scanning, scattered and spatially fractionated proton therapy
    Leite, A. M. M.
    Ronga, M. G.
    Giorgi, M.
    Ristic, Y.
    Perrot, Y.
    Trompier, F.
    Prezado, Y.
    Crehange, G.
    De Marzi, L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (22)