Clinical evaluation of plasma insulin and C-peptide levels with 3 different high-flux dialyzers in diabetic patients on hemodialysis

被引:6
作者
Abe, M. [1 ]
Okada, K. [1 ]
Maruyama, T. [1 ]
Inoshita, A. [1 ]
Ikeda, K. [1 ]
Uto, E. [1 ]
Kikuchi, F. [2 ]
Matsumoto, K. [1 ]
机构
[1] Nihon Univ, Div Nephrol Hypertens & Endocrinol, Dept Med, Sch Med,Itabashi Ku, Tokyo 1738610, Japan
[2] Yamato Hosp, Dept Nephrol & Blood Purificat, Tokyo, Japan
关键词
C-peptide; Diabetes mellitus; Hemodialysis; Insulin;
D O I
10.1177/039139880803101006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Aim: Changes in plasma immunoreactive insulin (IRI) and connecting-pep tide immunoreactivity (CPR) concentrations during hemodialysis (HD) were evaluated in diabetic HD patients with 3 different high-flux membranes. The removal properties of the membranes were compared. Method: In this prospective controlled study, 15 stable diabetic patients on HD were randomly selected for 6 HD sessions with 3 different membranes: polysulfone (PS), cellulose triacetate (CTA), and polymethylmethactylate (PMMA). Blood samples were obtained from the blood tubing at the arterial (A) site at the beginning and end of the sixth HD session. At 60 minutes after dialysis initiation, blood samples were obtained from both the A and venous (V) sites of the dialyzer to investigate the clearance and removal properties of the membranes. Results: The plasma IRI and CPR levels decreased significantly at each time point with all 3 membranes. IRI clearance with the PS membrane was significantly higher than that with the CTA and PMMA membranes. No difference was observed in the IRI reduction rate between the 3 membranes. CPR clearance and reduction rate with the PMMA membrane were lower than with the PS and CTA membranes. No significant difference was observed in serum creatinine clearance and reduction rates between the 3 membranes; however, serum urea nitrogen clearance was significantly lower with the PMMA membrane compared with the PS and CTA membranes. A significantly high beta 2-microglobulin clearance and reduction rate was achieved in the order PS > CTA > PMMA. Conclusion: Plasma IRI and CPR are cleared by HD; their clearance rates differ with the dialyzer membranes. Plasma IRI clearance with the PS membrane is higher than that with the CTA and PMMA membranes. (Int J Artif Organs 2008, 31: 898-904)
引用
收藏
页码:898 / 904
页数:7
相关论文
共 10 条
[1]  
AVRAM MM, 1976, T AM SOC ART INT ORG, V22, P412
[2]   A new polymethylmethacrylate membrane for hemodialysis [J].
Bonomini, M ;
Fiederling, B ;
Bucciarelli, T ;
Manfrini, V ;
Diilio, C ;
Albertazzi, A .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1996, 19 (04) :232-239
[3]   β2-microglobulin, a uremic toxin with a double meaning [J].
Canaud, B ;
Morena, M ;
Cristol, JP ;
Krieter, D .
KIDNEY INTERNATIONAL, 2006, 69 (08) :1297-1299
[4]   On-line haemodiafiltration: state of the art [J].
Canaud, B ;
Bose, JY ;
Leray, H ;
Stec, F ;
Argiles, A ;
Leblanc, M ;
Mion, C .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 :3-11
[5]  
COLTON CK, 1975, J LAB CLIN MED, V85, P355
[6]  
*EUR REN ASS, 2002, NEPHROL DIAL TRAN S7, V17, pS21
[7]  
KABANDA A, 1994, KIDNEY INT, V45, P1668
[8]   Change from conventional haemodiafiltration to on-line haemodiafiltration [J].
Maduell, F ;
del Pozo, C ;
Garcia, H ;
Sanchez, L ;
Hdez-Jaras, J ;
Albero, MD ;
Calvo, C ;
Torregrosa, I ;
Navarro, V .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1999, 14 (05) :1202-1207
[9]  
Miyata T, 1998, J AM SOC NEPHROL, V9, P1723
[10]   Comparison of the new polyethersulfone high-flux membrane DIAPES® HF800 with conventional high-flux membranes during on-line haemodiafiltration [J].
Samtleben, W ;
Dengler, C ;
Reinhardt, B ;
Nothdurft, A ;
Lemke, HD .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2003, 18 (11) :2382-2386