The relationship of visual threshold and reaction time to visual field eccentricity with conventional automated perimetry

被引:20
作者
Wall, M
Kutzko, KE
Chauhan, BC
机构
[1] Univ Iowa, Vet Adm Hosp, Dept Neurol, Coll Med, Iowa City, IA 52242 USA
[2] Univ Iowa, Coll Med, Dept Ophthalmol, Vet Adm Hosp, Iowa City, IA 52242 USA
[3] Dalhousie Univ, Dept Ophthalmol, Halifax, NS, Canada
基金
英国医学研究理事会;
关键词
perimetry; reaction times; visual testing; variability; eccentricity; reliability;
D O I
10.1016/S0042-6989(01)00311-X
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
To investigate the relationship between reaction time (RT), stimulus intensity and visual field eccentricity. We generated frequency of seeing (FOS) curves and measured RTs by testing 10 perimetrically experienced normal subjects with a Humphrey perimeter controlled by a custom program. Subjects were tested from 10degrees to 50degrees eccentricity along the nasal horizontal meridian in 100 increments. A range of 20 dB, centered on threshold, was tested in I dB steps along with 60 and 0 dB intensities as catch trials. Twenty repetitions for each intensity at each location were used. Linear regression showed a significant increase in suprathreshold RT (to the 0 dB stimulus) with increasing eccentricity. The RT at the calculated FOS 50% threshold was prolonged by about 200 ms compared with the RT using the 0 dB target at the equivalent eccentricities. Also, when the difference between the RT at 0 dB stimulus and the RT at threshold was regressed against visual field eccentricity there was a significant decrease with eccentricity. When the RTpi (RT prolongation from threshold relative to the 0 dB stimulus) was plotted as a function of decreasing stimulus attenuation, the results fit the function RTpi = a + bi(3) (i = stimulus intensity) with r(2) > 0.94 at all eccentricities. However, the slope of the function flattened with increasing eccentricity. Using conventional automated perimetry stimuli in perimetrically experienced young subjects, suprathreshold RT increases but threshold RT prolongation decreases with increasing visual field eccentricity. RT fits a power function with decreasing stimulus attenuation but the slope flattens with eccentricity. This relationship found along the nasal horizontal meridian may allow use of RT to cross-check threshold results or to define response windows for reliability indices of conventional automated perimetry. Published by Elsevier Science Ltd.
引用
收藏
页码:781 / 787
页数:7
相关论文
共 22 条
  • [21] Wall M, 1996, INVEST OPHTH VIS SCI, V37, P878
  • [22] Wall M, 1997, INVEST OPHTH VIS SCI, V38, P426