Study of broken bars in three-phase squirrel-cage induction motors at standstill

被引:9
作者
Xie, Ying [1 ,2 ]
Gu, Chenglin [2 ]
Cao, Wenping [3 ]
机构
[1] Harbin Univ Sci & Technol, Sch Elect & Elect Engn, Harbin 150080, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, Wuhan 430074, Peoples R China
[3] Newcastle Univ, Sch Elect Elect & Comp Engn, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
基金
中国国家自然科学基金;
关键词
induction motors; broken rotor bars; fault diagnosis; magnetic field; finite-element methods; END-RING FAULTS; ROTOR BARS; FINITE-ELEMENT; CHARACTERISTIC PERFORMANCE; SENSITIVE DETECTION; MACHINES; DIAGNOSIS; SIGNATURES; CURRENTS; DRIVE;
D O I
10.1002/etep.1642
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper investigates the characteristic performance of broken bar faults in induction motors at standstill by 2D time-stepping finite-element and experiential approaches. Three identical rotors with the same stator are employed to generate one healthy-rotor, one-broken-bar and two-broken-bar fault cases in a three-phase 1.1-kW squirrel-cage induction motor. The focus is placed on how the broken bar affects air-gap flux density, stator and rotor currents, torque and magnetic force, as well as iron and rotor bar losses. Numerical results are validated by some experimental measurements obtained from a dedicated test rig. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:1124 / 1138
页数:15
相关论文
共 36 条
[1]   Phase-sensitive detection of motor fault signatures in the presence of noise [J].
Akin, Bilal ;
Orguner, Urnut ;
Toliyat, Hamid A. ;
Rayner, Mark .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (06) :2539-2550
[2]   Multiple signature processing-based fault detection schemes for broken rotor bar in induction motors [J].
Ayhan, B ;
Chow, MY ;
Song, MH .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (02) :336-343
[3]  
Bangura JF, 1999, IEEE T ENERGY CONVER, V14, P1167, DOI 10.1109/60.815043
[4]   Quantitative evaluation of induction motor broken bars by means of electrical signature analysis [J].
Bellini, A ;
Filippetti, F ;
Franceschini, G ;
Tassoni, C ;
Kliman, GB .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (05) :1248-1255
[5]  
Bentong L, 1994, ELECT MACH TECHNOL, P37
[6]   On line diagnosis of defaults on squirrel cage motors using FEM [J].
Bentounsi, A ;
Nicolas, A .
IEEE TRANSACTIONS ON MAGNETICS, 1998, 34 (05) :3511-3514
[7]   Analysis and Application of Particular Current Signatures (Symptoms) for Cage Monitoring in Nonsinusoidally Fed Motors With High Rejection to Drive Load, Inertia, and Frequency Variations [J].
Bruzzese, Claudio .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (12) :4137-4155
[8]   A New Portable, Self-Powered, and Wireless Instrument for the Early Detection of Broken Rotor Bars in Induction Motors [J].
Cabanas, Manes F. ;
Pedrayes, Francisco ;
Rojas, Carlos H. ;
Melero, Manuel G. ;
Norniella, Joaquin G. ;
Orcajo, Gonzalo A. ;
Cano, Jose M. ;
Nuno, Fernando ;
Fuentes, David R. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (10) :4917-4930
[9]   An Impedance Identification Approach to Sensitive Detection and Location of Stator Turn-to-Turn Faults in a Closed-Loop Multiple-Motor Drive [J].
Cheng, Siwei ;
Zhang, Pinjia ;
Habetler, Thomas G. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (05) :1545-1554
[10]   Induction machine broken bar and stator short-circuit fault diagnostics based on three-phase stator current envelopes [J].
da Silva, Aderiano M. ;
Povinelli, Richard J. ;
Demerdash, Nabeel A. O. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (03) :1310-1318