Comb-Push Ultrasound Shear Elastography (CUSE) With Various Ultrasound Push Beams

被引:73
|
作者
Song, Pengfei [1 ,2 ]
Urban, Matthew W. [1 ]
Manduca, Armando [1 ]
Zhao, Heng [1 ]
Greenleaf, James F. [1 ]
Chen, Shigao [1 ]
机构
[1] Mayo Clin, Coll Med, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[2] Mayo Clin, Coll Med, Mayo Grad Sch, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
Acoustic radiation force; comb-push; comb-push ultrasound shear elastography (CUSE); focused ultrasound beam; shear wave; ultrasound elastography; unfocused ultrasound beam; ACOUSTIC RADIATION FORCE; SOFT-TISSUE; TRANSIENT ELASTOGRAPHY; CRAWLING WAVES; IN-VIVO; ELASTICITY; INTEGRATION; INVERSION; IMAGES;
D O I
10.1109/TMI.2013.2257831
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Comb-push ultrasound shear elastography (CUSE) has recently been shown to be a fast and accurate 2-D elasticity imaging technique that can provide a full field-of-view (FOV) shear wave speed map with only one rapid data acquisition. The initial version of CUSE was termed U-CUSE because unfocused ultrasound push beams were used. In this paper, we present two new versions of CUSE-focused CUSE (F-CUSE) and marching CUSE (M-CUSE), which use focused ultrasound push beams to improve acoustic radiation force penetration and produce stronger shear waves in deep tissues (e. g., kidney and liver). F-CUSE divides transducer elements into several subgroups which transmit multiple focused ultrasound beams simultaneously. M-CUSE uses more elements for each focused push beam and laterally marches the push beams. Both F-CUSE and M-CUSE can generate comb-shaped shear wave fields that have shear wave motion at each imaging pixel location so that a full FOV 2-D shear wave speed map can be reconstructed with only one data acquisition. Homogeneous phantom experiments showed that U-CUSE, F-CUSE, and M-CUSE can all produce smooth shear wave speed maps with accurate shear wave speed estimates. An inclusion phantom experiment showed that all CUSE methods could provide good contrast between the inclusion and background with sharp boundaries while F-CUSE and M-CUSE require shorter push durations to achieve shear wave speed maps with comparable SNR to U-CUSE. A more challenging inclusion phantom experiment with a very stiff and deep inclusion shows that better shear wave penetration could be gained by using F-CUSE and M-CUSE. Finally, a shallow inclusion experiment showed that good preservations of inclusion shapes could be achieved by both U-CUSE and F-CUSE in the near field. Safety measurements showed that all safety parameters are below FDA regulatory limits for all CUSE methods. These promising results suggest that, using various push beams, CUSE is capable of reconstructing a 2-D full FOV shear elasticity map using only one push-detection data acquisition in a wide range of depths for soft tissue elasticity imaging.
引用
收藏
页码:1435 / 1447
页数:13
相关论文
共 50 条
  • [41] Ultrasound elastography: compression elastography and shear-wave elastography in the assessment of tendon injury
    Prado-Costa, Rui
    Rebelo, Joao
    Monteiro-Barroso, Joao
    Preto, Ana Sofia
    INSIGHTS INTO IMAGING, 2018, 9 (05): : 791 - 814
  • [42] QUANTITATIVE ASSESSMENT OF SKIN STIFFNESS IN LOCALIZED SCLERODERMA USING ULTRASOUND SHEAR-WAVE ELASTOGRAPHY
    Wang, Liyun
    Yan, Feng
    Yang, Yujia
    Xiang, Xi
    Qiu, Li
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (07) : 1339 - 1347
  • [43] DSWE-Net: A deep learning approach for shear wave elastography and lesion segmentation using single push acoustic radiation force
    Ahmed, Shahed
    Kamal, Uday
    Hasan, Md. Kamrul
    ULTRASONICS, 2021, 110
  • [44] Comparison of ultrasound elastography, magnetic resonance elastography and finite element model to quantify nonlinear shear modulus
    Page, Gwenael
    Bied, Marion
    Garteiser, Philippe
    Van Beers, Bernard
    Etaix, Nicolas
    Fraschini, Christophe
    Bel-Brunon, Aline
    Gennisson, Jean-Luc
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (20)
  • [45] Chinese Ultrasound Doctors Association Guideline on Operational Standards for 2-D Shear Wave Elastography Examination of Musculoskeletal Tissues
    Zhu, Jiaan
    Qiu, Li
    Ta, Dean
    Hua, Xing
    Liu, Hongmei
    Zhang, Huabin
    Li, Jia
    Wang, Yuexiang
    Xi, Zhanguo
    Zheng, Yuanyi
    Shan, Yong
    Liu, Bingyan
    Huang, Weijun
    Liu, Weiyong
    Hao, Shaoyun
    Cui, Ligang
    Cai, Jin
    Zhang, Wei
    Zhang, Chao
    Chen, Shuqiang
    Wei, An
    Dong, Fajin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (02) : 175 - 183
  • [46] Muscle Ultrasound Shear Wave Elastography as a Non-Invasive Biomarker in Myotonia
    Kronlage, Cornelius
    Grimm, Alexander
    Romano, Alyssa
    Stahl, Jan-Hendrik
    Martin, Pascal
    Winter, Natalie
    Marquetand, Justus
    DIAGNOSTICS, 2021, 11 (02)
  • [47] Shear Wave Elastography Implementation on a Portable Research Ultrasound System: Initial Results
    Cacko, Damian
    Lewandowski, Marcin
    APPLIED SCIENCES-BASEL, 2022, 12 (12):
  • [48] An unsupervised learning-based shear wave tracking method for ultrasound elastography
    Delaunay, Remi
    Hun, Yipeng
    Vercauteren, Tom
    MEDICAL IMAGING 2022: ULTRASONIC IMAGING AND TOMOGRAPHY, 2022, 12038
  • [49] Comparison of Simulation Methods for Ultrasound Shear Wave Elastography: FEM vs. Green's Functions
    Zhou, Shiwei
    Huang, Sheng-Wen
    Xie, Hua
    Robert, Jean-Luc
    Shamdasani, Vijay
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 2304 - 2307
  • [50] Characterization of the extensor digitorum communis tendon using high-frequency ultrasound shear wave elastography
    Hsiao, Yan-Yi
    Yang, Tai-Hua
    Chen, Pei-Yu
    Hsu, Hsiu-Yun
    Kuo, Li-Chieh
    Su, Fong-Chin
    Huang, Chih-Chung
    MEDICAL PHYSICS, 2020, 47 (04) : 1609 - 1618