Factors affecting impedance of percutaneous leads in spinal cord stimulation

被引:25
作者
Alò, K
Varga, C
Krames, E
Prager, J
Holsheimer, J
Manola, L
Bradley, K
机构
[1] Pain & Hlth Management Ctr, Houston, TX 77090 USA
[2] Pasadena Rehabil Inst, Pasadena, CA USA
[3] Pacific Pain Treatment Ctr, San Francisco, CA USA
[4] Calif Pain Med Ctr, Los Angeles, CA USA
[5] Univ Twente, NL-7500 AE Enschede, Netherlands
[6] Adv Bion Corp, Valencia, CA USA
来源
NEUROMODULATION | 2006年 / 9卷 / 02期
关键词
electrical impedance; energy consumption; epidural space; percutaneous lead; spinal cord stimulation;
D O I
10.1111/j.1525-1403.2006.00050.x
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives. Although the load impedance of a pulse generator has a significant effect on battery life, the electrical impedance of contact arrays in spinal cord stimulation (SCS) has not been extensively studied. We sought to characterize the typical impedance values measured from common quadripolar percutaneous SCS contact arrays. Methods. In 36 patients undergoing percutaneous trial stimulation for various chronic pain conditions, bipolar impedance between adjacent contacts of 64 leads with 9 mm center-to-center spacing was measured in two different vertebral level regions, cervical (C3-C7) and lower-thoracic (T7-T12). Multiple linear regression was applied to analyze the contribution of six variables to the biological tissue portion of the impedance (excluding the resistance of the lead wires). Results. The median impedance in the cervical region (351 +/- 90 Omega) was significantly lower (36%, p < 0.001) than in the lower-thoracic region (547 +/- 151 Omega). In addition, time since implant had a weaker but still significant effect on tissue impedance. Conclusions. Results from finite-difference mathematical modeling of SCS suggest that the difference in tissue impedance related to vertebral level may be due to the dorsoventral position of the lead in the epidural space. The presence of a larger space between the triangularly shaped dorsal part of the vertebral arch and the round shape of the dural sac in the lower-thoracic region increases the likelihood that the stimulating lead will not make dural contact, and thus "see" an increased impedance from the surrounding epidural fat. This implies that the energy requirements for stimulation in the thoracic region will be higher than in the cervical region, at least during the acute phase of implant.
引用
收藏
页码:128 / 135
页数:8
相关论文
共 23 条
  • [1] New trends in neuromodulation for the management of neuropathic pain
    Aló, KM
    Holsheimer, J
    [J]. NEUROSURGERY, 2002, 50 (04) : 690 - 703
  • [2] Altman DG, 1990, PRACTICAL STAT MED R
  • [3] Time dependent variations of stimulus requirements in spinal cord stimulation for angina pectoris
    Andersen, C
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (02): : 359 - 363
  • [4] Barolat G, 2000, NEUROL RES, V22, P279
  • [5] MULTIFACTORIAL ANALYSIS OF EPIDURAL SPINAL-CORD STIMULATION
    BAROLAT, G
    ZEME, S
    KETCIK, B
    [J]. STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1991, 56 (02) : 77 - 103
  • [6] Barolat Giancarlo, 1993, Stereotactic and Functional Neurosurgery, V61, P60, DOI 10.1159/000100624
  • [7] DEJONGSTE MJL, 1994, PACE, V17, P1751
  • [8] ELECTRICAL-PROPERTIES OF IMPLANT ENCAPSULATION TISSUE
    GRILL, WM
    MORTIMER, JT
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1994, 22 (01) : 23 - 33
  • [9] PERCEPTION THRESHOLD AND ELECTRODE POSITION FOR SPINAL-CORD STIMULATION
    HE, JP
    BAROLAT, G
    HOLSHEIMER, J
    STRUIJK, JJ
    [J]. PAIN, 1994, 59 (01) : 55 - 63
  • [10] HOLSHEIMER J, 1994, AM J NEURORADIOL, V15, P951