Self-Gated Late Gadolinium Enhancement at 7T to Image Rats with Reperfused Acute Myocardial Infarction

被引:4
|
作者
Wang, Lei [1 ]
Chen, Yushu [2 ]
Zhang, Bing [2 ]
Chen, Wei [2 ]
Wang, Chunhua [2 ]
Song, Li [1 ]
Xu, Ziqian [2 ]
Zheng, Jie [3 ]
Gao, Fabao [2 ]
机构
[1] Sichuan Univ, Mol Imaging Ctr, West China Hosp, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, Dept Radiol, West China Hosp, 37 Guoxue Alley, Chengdu 610041, Sichuan, Peoples R China
[3] Washington Univ, Mallinckrodt Inst Radiol, Sch Med, St Louis, MO 63110 USA
基金
中国国家自然科学基金;
关键词
Self-gated; Myocardial infarction; Flip angle; MRI; Late gadolinium enhancement; Animal studies; 7T; FLIP ANGLE OPTIMIZATION; CARDIAC CINE MRI; HEART-RATE; CONTRAST; FLASH; MICE; SEQUENCE; SYSTEM; MOUSE; 3T;
D O I
10.3348/kjr.2018.19.2.247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: A failed electrocardiography (ECG)-trigger often leads to a long acquisition time (TA) and deterioration in image quality. The purpose of this study was to evaluate and optimize the technique of self-gated (SG) cardiovascular magnetic resonance (CMR) for cardiac late gadolinium enhancement (LGE) imaging of rats with myocardial infarction/reperfusion. Materials and Methods: Cardiovascular magnetic resonance images of 10 rats were obtained using SG-LGE or ECG with respiration double-gating (ECG-RESP-gating) method at 7T to compare differences in image interference and TA between the two methods. A variety of flip angles (FA: 10 degrees-80 degrees) and the number of repetitions (NR: 40, 80, 150, and 300) were investigated to determine optimal scan parameters of SG-LGE technique based on image quality score and contrast-to-noise ratio (CNR). Results: Self-gated late gadolinium enhancement allowed successful scan in 10 (100%) rats. However, only 4 (40%) rats were successfully scanned with the ECG-RESP-gating method. TAs with SG-LGE varied depending on NR used (TA: 41, 82, 154, and 307 seconds, corresponding to NR of 40, 80, 150, and 300, respectively). For the ECG-RESP-gating method, the average TA was 220 seconds. For SG-LGE images, CNR (42.5 +/- 5.5, 43.5 +/- 7.5, 54 +/- 9, 59.5 +/- 8.5, 56 +/- 13, 54 +/- 8, and 41 +/- 9) and image quality score (1.85 +/- 0.75, 2.20 +/- 0.83, 2.85 +/- 0.37, 3.85 +/- 0.52, 2.8 +/- 0.51, 2.45 +/- 0.76, and 1.95 +/- 0.60) were achieved with different FAs (10 degrees, 15 degrees, 20 degrees, 25 degrees, 30 degrees, 35 degrees, and 40 degrees, respectively). Optimal FAs of 20 degrees-30 degrees and NR of 80 were recommended. Conclusion: Self-gated technique can improve image quality of LGE without irregular ECG or respiration gating. Therefore, SG-LGE can be used an alternative method of ECG-RESP-gating.
引用
收藏
页码:247 / 255
页数:9
相关论文
共 50 条
  • [31] Determination of the area at risk using quantitative T2 mapping in re-perfused myocardial infarction; a comparison with late gadolinium enhancement and CINE imaging
    Tae Hoon Kim
    Eui-Young Choi
    Chul Hwan Park
    Sung Ho Hwang
    Sang Jin Kim
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [32] Assessment of myocardial infarction in mice by Late Gadolinium Enhancement MR imaging using an inversion recovery pulse sequence at 9.4T
    Catherine Chapon
    Amy H Herlihy
    Kishore K Bhakoo
    Journal of Cardiovascular Magnetic Resonance, 10
  • [33] Late gadolinium enhancement magnetic resonance imaging for the assessment of myocardial infarction: comparison of image quality between single and double doses of contrast agents
    Yeo Koon Kim
    Eun-Ah Park
    Whal Lee
    Sang Yoon Kim
    Jin Wook Chung
    The International Journal of Cardiovascular Imaging, 2014, 30 : 129 - 135
  • [34] Late gadolinium enhancement magnetic resonance imaging for the assessment of myocardial infarction: comparison of image quality between single and double doses of contrast agents
    Kim, Yeo Koon
    Park, Eun-Ah
    Lee, Whal
    Kim, Sang Yoon
    Chung, Jin Wook
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 : 129 - 135
  • [35] Acute, Subacute, and Chronic Myocardial Infarction: Quantitative Comparison of 2D and 3D Late Gadolinium Enhancement MR Imaging
    Goetti, Robert
    Kozerke, Sebastian
    Donati, Olivio F.
    Suerder, Daniel
    Stolzmann, Paul
    Kaufmann, Philipp A.
    Luescher, Thomas F.
    Corti, Roberto
    Manka, Robert
    RADIOLOGY, 2011, 259 (03) : 704 - 711
  • [36] Characterization of microvascular dysfunction after acute myocardial infarction by cardiovascular magnetic resonance first-pass perfusion and late gadolinium enhancement imaging
    Yan, Andrew T.
    Gibson, C. Michael
    Larose, Eric
    Anavekar, Nagesh S.
    Tsang, Sui
    Solomon, Scott D.
    Reynolds, Glenn
    Kwong, Raymond Y.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2006, 8 (06) : 831 - 837
  • [37] Appearance of microvascular obstruction on high resolution first-pass perfusion, early and late gadolinium enhancement CMR in patients with acute myocardial infarction
    Adam N Mather
    Timothy Lockie
    Eike Nagel
    Michael Marber
    Divaka Perera
    Simon Redwood
    Aleksandra Radjenovic
    Ansuman Saha
    John P Greenwood
    Sven Plein
    Journal of Cardiovascular Magnetic Resonance, 11
  • [38] Comparison of acquisition time and dose for late gadolinium enhancement imaging at 3.0 T in patients with chronic myocardial infarction using Gd-BOPTA
    A. Doltra
    A. Skorin
    A. Hamdan
    B. Schnackenburg
    R. Gebker
    C. Klein
    E. Nagel
    E. Fleck
    S. Kelle
    European Radiology, 2014, 24 : 2192 - 2200
  • [39] Investigation of T2-weighted signal intensity of infarcted myocardium and its correlation with delayed enhancement magnetic resonance imaging in a porcine model with reperfused acute myocardial infarction
    Choi, Seong Hoon
    Kang, Joon-Won
    Kim, Sang-Tae
    Lee, Byung Han
    Chun, Eun Ju
    Schuleri, Karl H.
    Choi, Sang Il
    Lim, Tae-Hwan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 : 111 - 119
  • [40] An experimental study on use of 7T MRI for evaluation of myocardial infarction in SD rats transfected with pcDNA 3.1(+)/ VEGF121 plasmid
    Zhang, Yan
    Tian, Ruiqing
    Shen, Xiangchun
    Chen, Yushu
    Chen, Wei
    Gan, Lu
    Shen, Guiquan
    Ju, Haiyue
    Yang, Li
    Gao, Fabao