Modular junction may be more problematic than bearing wear in metal-on-metal total hip arthroplasty

被引:14
作者
Vendittoli, Pascal-Andre [1 ]
Masse, Vincent [1 ]
Kiss, Marc-Olivier [1 ]
Lusignan, Daniel [1 ]
Lavigne, Martin [1 ]
机构
[1] Univ Montreal, Dept Surg, Hosp Maisonneuve Rosemont, Montreal, PQ, Canada
关键词
Adverse reaction to metal debris; metal ions; metal-on-metal joint prostheses; modular stem; taper junction; total hip arthroplasty; CHROMIUM SERUM-LEVELS; ION LEVELS; NECKS ANALYSIS; CERAMIC THR; LARGE-HEAD; CORROSION; COBALT; REPLACEMENT; INTERFACE; RELEASE;
D O I
10.1177/1120700018808696
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: In total hip arthroplasty (THA), local adverse reaction to metal debris (ARMD) may be caused by abnormal metal ion release from a metal-on-metal (MoM) bearing, or by wear and corrosion of the implant's modular junction. The aim of this study was to compare ion levels and rate of ARMD between patients sharing the same MoM bearing but 1 group having monoblock stems versus another having modular stems. Materials and methods: Whole blood cobalt (Co) and chromium (Cr) ion concentrations, ARMD rate, revision rate, and function measured by UCLA and WOMAC scores were compared between groups. Results: ARMD rate was significantly higher in the modular group (46%) compared with the monoblock group (16%, p = 0.031). Revision for ARMD was performed at 52.8 +/- 8.1 months in the modular group versus 98.2 +/- 15.5 months after primary THA in the monoblock group. ARMD originated from wear and corrosion of the junction between stem and femoral head adapter sleeve in all monoblock cases, and the junction between stem and modular neck in all the modular ones. Cr and Co ions levels were significantly higher in the modular stem group (p < 0.001 for both). Conclusions: Although both groups had MoM bearings, corrosion at stem/neck or neck/head junctions combining dissimilar metal (Ti and Cr-Co) was seen as the source of excess metal ions release leading to ARMD. Poor performance of the modular junction may be more deleterious than wear of the bearing. To avoid such complications, THA femoral stem modular junctions should be eliminated (return to a full monoblock implant) or have improved junction design.
引用
收藏
页码:262 / 269
页数:8
相关论文
共 50 条
  • [31] Metal-on-metal or metal-on-polyethylene for total hip arthroplasty: a meta-analysis of prospective randomized studies
    Qu, Xinhua
    Huang, Xiaolu
    Dai, Kerong
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (11) : 1573 - 1583
  • [32] Pinnacle® modular metal-on-metal articulation in primary total hip arthroplasty: mid-term results of 195 cases
    Colen, Sascha
    Kuiper, Jesse W. P.
    Thys, Philip
    De Schuyffeleer, Sten
    Mulier, Michiel
    ACTA ORTHOPAEDICA BELGICA, 2018, 84 (04): : 407 - 414
  • [33] Metal-on-Metal Hip Arthroplasty: A Comprehensive Review of the Current Literature
    Davis, Timothy P.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [34] Midterm results with Birmingham Hip Resurfacing/Synergy stem modular metal-on-metal total hip arthroplasty
    Hosny, Hazem A. H.
    Srinivasan, Sreebala C. M.
    Keenan, Jonathan
    Fekry, Helmy
    ACTA ORTHOPAEDICA BELGICA, 2013, 79 (04): : 386 - 391
  • [35] Pseudotumor in the Setting of Metal-on-Metal Total Hip Arthroplasty
    Sagoo, Navraj S.
    Sharma, Ruhi
    Johnson, Connor S.
    Stephenson, Kelly
    Aya, Kessiena L.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (05)
  • [36] Outcome of revision arthroplasty for failed metal-on-metal total hip replacements; is there a relation with metal ions?
    Iqbal, Hafiz J.
    Al-Azzani, Waheeb A. K.
    Jackson-Taylor, Esther
    Clatworthy, Elizabeth
    John, Alun
    HIP INTERNATIONAL, 2017, 27 (03) : 235 - 240
  • [37] Femoral offset found not to affect metal ion levels in metal-on-metal total hip arthroplasty
    Eoghan Pomeroy
    Fergal Macnamara
    Evelyn Murphy
    Niall McGoldrick
    Anant Mahapatra
    Nasir Awan
    Irish Journal of Medical Science (1971 -), 2019, 188 : 149 - 153
  • [38] Predictive factors for metal ion levels in metal-on-metal total hip arthroplasty
    Maximilian F. Kasparek
    Lisa Renner
    Martin Faschingbauer
    Wenzel Waldstein
    Michael Weber
    Friedrich Boettner
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 281 - 286
  • [39] Midterm results of 36 mm metal-on-metal total hip arthroplasty
    Akrawi, Hawar
    Hossain, Fahad S.
    Niculescu, Stefan
    Hashim, Zaid
    Ng, Arron Biing
    Shetty, Ajit
    INDIAN JOURNAL OF ORTHOPAEDICS, 2016, 50 (03) : 256 - 262
  • [40] Early failures in large head metal-on-metal total hip arthroplasty
    Althuizen, Martje N. R.
    Hooff, Miranda L. V.
    Erp, Saskia H. M. V. D. Berg-v.
    Limbeek, Jacques V.
    Nijhof, Marc W.
    HIP INTERNATIONAL, 2012, 22 (06) : 641 - 647