Diffusion-Weighted Imaging of the Head and Neck: Influence of Fat-Suppression Technique and Multishot 2D Navigated Interleaved Acquisitions

被引:14
作者
Bae, Y. J. [1 ]
Choi, B. S. [1 ]
Jeong, H. -K. [2 ]
Sunwoo, L. [1 ]
Jung, C. [1 ]
Kim, J. H. [1 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Dept Radiol, 82,Gumi Ro 173 Beon Gil, Seongnam 13620, South Korea
[2] Philips Korea, Seoul, South Korea
关键词
TIME INVERSION-RECOVERY; BREAST-LESIONS; MR; COEFFICIENT; EXPERIENCE; PULSE; STIR;
D O I
10.3174/ajnr.A5426
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DWI of the head and neck can reveal valuable information, but the effects of fat suppression and multishot acquisition on image quality have not been thoroughly investigated. We aimed to comprehensively compare the quality of head and neck DWI at 3T using 2 fat-suppression techniques, STIR, and spectral presaturation with inversion recovery, which were used with both single- and multishot EPI. MATERIALS AND METHODS: Sixty-five study participants underwent 3 DWI sequences of single-shot EPI-STIR, single-shot EPI-spectral presaturation with inversion recovery, and multishot EPI-spectral presaturation with inversion recovery of the head and neck. In multiple anatomic regions, 2 independent readers assessed 5-point visual scores for fat-suppression uniformity and image distortion, and 1 reader measured the contrast-to-noise ratio and ADC. RESULTS: The mean visual score for fat-suppression uniformity was higher in single-shot EPI-STIR than in other sequences (all regions except for the orbital region, P < .05). The mean visual score for image distortion was higher in multishot EPI-spectral presaturation with inversion recovery than in single-shot EPI sequences (all regions, P < .001). Contrast-to-noise ratio was mostly lower in single-shot EPI-STIR than in other sequences (P < .001), and ADC was significantly higher in multishot EPI-spectral presaturation with inversion recovery than in single-shot EPI sequences (P <= .001). CONCLUSIONS: Overall, multishot EPI-spectral presaturation with inversion recovery provided the best image quality, with relatively homogeneous fat suppression, less image distortion than single-shot EPI sequences, and higher contrast-to-noise ratio than single-shot EPI-STIR. The measured ADC values can be higher in multishot EPI-spectral presaturation with inversion recovery, which necessitates cautious application of the previously reported ADC values to clinical settings.
引用
收藏
页码:145 / 150
页数:6
相关论文
共 24 条
  • [21] Head and Neck Squamous Cell Carcinoma: Value of Diffusion-weighted MR Imaging for Nodal Staging
    Vandecaveye, Vincent
    De Keyzer, Frederik
    Vander Poorten, Vincent
    Dirix, Piet
    Verbeken, Eric
    Nuyts, Sandra
    Hermans, Robert
    [J]. RADIOLOGY, 2009, 251 (01) : 134 - 146
  • [22] Diffusion weighted Imaging in breast MRI: Comparison of two different pulse sequences
    Wenkel, Evelyn
    Geppert, Christian
    Schulz-Wendtland, Ruediger
    Uder, Michael
    Kiefer, Berthold
    Bautz, Werner
    Janka, Rolf
    [J]. ACADEMIC RADIOLOGY, 2007, 14 (09) : 1077 - 1083
  • [23] Diffusion-weighted Imaging of the Breast: Principles and Clinical Applications
    Woodhams, Reiko
    Ramadan, Saadallah
    Stanwell, Peter
    Sakamoto, Satoko
    Hata, Hirofumi
    Ozaki, Masanori
    Kan, Shinichi
    Inoue, Yusuke
    [J]. RADIOGRAPHICS, 2011, 31 (04) : 1059 - 1084
  • [24] Readout-segmented echo-planar imaging in the evaluation of sinonasal lesions: A comprehensive comparison of image quality in single-shot echo-planar imaging
    Zhao, Menglong
    Liu, Zhuang
    Sha, Yan
    Wang, Shenjiang
    Ye, Xinpei
    Pan, Yucheng
    Wang, Shaoyu
    [J]. MAGNETIC RESONANCE IMAGING, 2016, 34 (02) : 166 - 172