Diffusion-Weighted Imaging of the Head and Neck: Influence of Fat-Suppression Technique and Multishot 2D Navigated Interleaved Acquisitions

被引:14
作者
Bae, Y. J. [1 ]
Choi, B. S. [1 ]
Jeong, H. -K. [2 ]
Sunwoo, L. [1 ]
Jung, C. [1 ]
Kim, J. H. [1 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Dept Radiol, 82,Gumi Ro 173 Beon Gil, Seongnam 13620, South Korea
[2] Philips Korea, Seoul, South Korea
关键词
TIME INVERSION-RECOVERY; BREAST-LESIONS; MR; COEFFICIENT; EXPERIENCE; PULSE; STIR;
D O I
10.3174/ajnr.A5426
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DWI of the head and neck can reveal valuable information, but the effects of fat suppression and multishot acquisition on image quality have not been thoroughly investigated. We aimed to comprehensively compare the quality of head and neck DWI at 3T using 2 fat-suppression techniques, STIR, and spectral presaturation with inversion recovery, which were used with both single- and multishot EPI. MATERIALS AND METHODS: Sixty-five study participants underwent 3 DWI sequences of single-shot EPI-STIR, single-shot EPI-spectral presaturation with inversion recovery, and multishot EPI-spectral presaturation with inversion recovery of the head and neck. In multiple anatomic regions, 2 independent readers assessed 5-point visual scores for fat-suppression uniformity and image distortion, and 1 reader measured the contrast-to-noise ratio and ADC. RESULTS: The mean visual score for fat-suppression uniformity was higher in single-shot EPI-STIR than in other sequences (all regions except for the orbital region, P < .05). The mean visual score for image distortion was higher in multishot EPI-spectral presaturation with inversion recovery than in single-shot EPI sequences (all regions, P < .001). Contrast-to-noise ratio was mostly lower in single-shot EPI-STIR than in other sequences (P < .001), and ADC was significantly higher in multishot EPI-spectral presaturation with inversion recovery than in single-shot EPI sequences (P <= .001). CONCLUSIONS: Overall, multishot EPI-spectral presaturation with inversion recovery provided the best image quality, with relatively homogeneous fat suppression, less image distortion than single-shot EPI sequences, and higher contrast-to-noise ratio than single-shot EPI-STIR. The measured ADC values can be higher in multishot EPI-spectral presaturation with inversion recovery, which necessitates cautious application of the previously reported ADC values to clinical settings.
引用
收藏
页码:145 / 150
页数:6
相关论文
共 24 条
  • [1] Diffusion-weighted imaging of normal fibroglandular breast tissue: influence of microperfusion and fat suppression technique on the apparent diffusion coefficient
    Baron, Paul
    Dorrius, Monique D.
    Kappert, Peter
    Oudkerk, Matthijs
    Sijens, Paul E.
    [J]. NMR IN BIOMEDICINE, 2010, 23 (04) : 399 - 405
  • [2] Fat suppression techniques (STIR vs. SPAIR) on diffusion-weighted imaging of breast lesions at 3.0 T: preliminary experience
    Brandao, Sofia
    Nogueira, Luisa
    Matos, Eduarda
    Nunes, Rita Gouveia
    Ferreira, Hugo Alexandre
    Loureiro, Joana
    Ramos, Isabel
    [J]. RADIOLOGIA MEDICA, 2015, 120 (08): : 705 - 713
  • [3] Effects of, and corrections for, cross-term interactions in Q-space MRI
    Brihuega-Moreno, O
    Heese, FP
    Tejos, C
    Hall, LD
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) : 1048 - 1054
  • [4] Multishot diffusion-weighted PROPELLER magnetic resonance imaging of the abdomen
    Deng, Jie
    Miller, Frank H.
    Salem, Riad
    Omary, Reed A.
    Larson, Andrew C.
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (10) : 769 - 775
  • [5] Fleiss J. L., 1981, STAT METHODS RATES P
  • [6] Apparent Diffusion Coefficient: a quantitative parameter for in vivo tumor characterization
    Herneth, AM
    Guccione, S
    Bednarski, M
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 (03) : 208 - 213
  • [7] Improved Diffusion Tensor Imaging of the Optic Nerve Using Multishot Two-Dimensional Navigated Acquisitions
    Jeong, Ha-Kyu
    Dewey, Blake E.
    Hirtle, Jane A. T.
    Lavin, Patrick
    Sriram, Subramaniam
    Pawate, Siddharama
    Gore, John C.
    Anderson, Adam W.
    Kang, Hakmook
    Smith, Seth A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (04) : 953 - 963
  • [8] High-resolution human diffusion tensor imaging using 2-D navigated multishot SENSE EPI at 7 T
    Jeong, Ha-Kyu
    Gore, John C.
    Anderson, Adam W.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (03) : 793 - 802
  • [9] Comparison of diffusion-weighted images using short inversion time inversion recovery or chemical shift selective pulse as fat suppression in patients with breast cancer
    Kazama, Toshiki
    Nasu, Katsuhiro
    Kuroki, Yoshifumi
    Nawano, Shigeru
    Ito, Hisao
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2009, 27 (04): : 163 - 167
  • [10] Role of diffusion weighted MR in the discrimination diagnosis of the cystic and/or necrotic head and neck lesions
    Koc, Osman
    Paksoy, Yahya
    Erayman, Ibrahim
    Kivrak, Ali Sami
    Arbag, Hamdi
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2007, 62 (02) : 205 - 213