Local micromechanical properties of decellularized lung scaffolds measured with atomic force microscopy

被引:70
|
作者
Luque, T. [1 ,2 ,4 ]
Melo, E. [1 ,3 ,4 ]
Garreta, E. [1 ,3 ,4 ]
Cortiella, J. [5 ]
Nichols, J. [5 ]
Farre, R. [1 ,3 ,4 ]
Navajas, D. [1 ,2 ,4 ]
机构
[1] Univ Barcelona, Sch Med, Unit Biophys & Bioengn, E-08036 Barcelona, Spain
[2] Inst Bioengn Catalonia, Barcelona, Spain
[3] IDIBAPS, Barcelona, Spain
[4] CIBERES, Bunyola, Spain
[5] Univ Texas Med Branch, Galveston, TX 77555 USA
关键词
Biological scaffolds; Extracellular matrix mechanics; Alveolar mechanics; Atomic force microscopy; Bioengineered lungs; COLLAGEN NETWORKS; SLOW DYNAMICS; MATRIX; CELLS; SUBSTRATE; TISSUE; MECHANICS; BEHAVIOR; TRANSPLANTATION; STIFFNESS;
D O I
10.1016/j.actbio.2013.02.044
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bioartificial lungs re-engineered from decellularized organ scaffolds are a promising alternative to lung transplantation. Critical features for improving scaffold repopulation depend on the mechanical properties of the cell microenvironment. However, the mechanics of the lung extracellular matrix (ECM) is poorly defined. The local mechanical properties of the ECM were measured in different regions of decellularized rat lung scaffolds with atomic force microscopy. Lungs excised from rats (n = 11) were decellularized with sodium dodecyl sulfate (SOS) and cut into similar to 7 mu m thick slices. The complex elastic modulus (G*) of lung ECM was measured over a frequency band ranging from 0.1 to 11.45 Hz. Measurements were taken in alveolar walLsegments, alveolar wall junctions and pleural regions. The storage modulus (G', real part of G*) of alveolar ECM was similar to 6 kPa, showing small changes between wall segments and junctions. Pleural regions were threefold stiffer than alveolar walls. G' of alveolar walls and pleura increased with frequency as a weak power law with exponent 0.05. The loss modulus (G '', imaginary part of G*) was 10-fold lower and showed a frequency dependence similar to that of G' at low frequencies (0.1-1 Hz), but increased more markedly at higher frequencies. Local differences in mechanical properties and topology of the parenchymal site could be relevant mechanical cues for regulating the spatial distribution, differentiation and function of lung cells. (C) 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:6852 / 6859
页数:8
相关论文
共 50 条
  • [21] Atomic force microscopy reveals regional variations in the micromechanical properties of the pericellular and extracellular matrices of the meniscus
    Sanchez-Adams, Johannah
    Wilusz, Rebecca E.
    Guilak, Farshid
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (08) : 1218 - 1225
  • [22] Micromechanical properties of reaction-bonded silicon carbide using atomic force microscopy and nanoindentation
    Lapitskaya, V.
    Kuznetsova, T.
    Grinchuk, P.
    Khabarava, A.
    Chizhik, S.
    Luikov, A. V.
    CERAMICS INTERNATIONAL, 2024, 50 (24) : 52981 - 52998
  • [23] Micromechanical contact stiffness devices and application for calibrating contact resonance atomic force microscopy
    Rosenberger, Matthew R.
    Chen, Sihan
    Prater, Craig B.
    King, William P.
    NANOTECHNOLOGY, 2017, 28 (04)
  • [24] Micro-Mechanical Characterization of Lung Tissue Using Atomic Force Microscopy
    Liu, Fei
    Tschumperlin, Daniel J.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2011, (54):
  • [25] Vickers hardness indentations measured with atomic force microscopy
    Jensen, CP
    Jorgensen, JF
    Garnaes, J
    Picotto, GB
    Gori, C
    JOURNAL OF TESTING AND EVALUATION, 1998, 26 (06) : 532 - 538
  • [26] Micromechanical characterization of zwitterionic polymer brushes based on the atomic force microscopy
    Yang, Hegang
    Song, Xinzhong
    Qiu, Yinghua
    Zhang, Yongqi
    Li, Jianfeng
    Li, Jianyong
    Man, Jia
    APPLIED SURFACE SCIENCE, 2024, 665
  • [27] MICROMECHANICAL ANALYSIS OF MOUSE AORTIC VALVE LEAFLETS WITH ATOMIC FORCE MICROSCOPY
    Sewell-Loftin, M. K.
    Brown, Christopher B.
    Baldwin, H. Scott
    Merryman, W. David
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 1273 - 1274
  • [28] Deformability and adhesive force of artificial platelets measured by atomic force microscopy
    Wada, Toru
    Okamura, Yosuke
    Takeoka, Shinji
    Sudo, Ryo
    Ikeda, Yasuo
    Tanishita, Kazuo
    Journal of Biorheology, 2009, 23 (01) : 35 - 40
  • [29] Micromechanical bending of single collagen fibrils using atomic force microscopy
    Yang, Lanti
    van der Werf, Kees O.
    Koopman, Bart F. J. M.
    Subramaniam, Vinod
    Bennink, Martin L.
    Dijkstra, Pieter J.
    Feijen, Jan
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 82A (01) : 160 - 168
  • [30] Influence of Lamin A on the Mechanical Properties of Amphibian Oocyte Nuclei Measured by Atomic Force Microscopy
    Schaepe, Jens
    Prausse, Steffi
    Radmacher, Manfred
    Stick, Reimer
    BIOPHYSICAL JOURNAL, 2009, 96 (10) : 4319 - 4325