Compound-specific stable carbon isotope ratios of phenols and nitrophenols derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide

被引:9
作者
Irei, Satoshi [1 ,2 ]
Rudolph, Jochen [1 ]
Huang, Lin [2 ]
机构
[1] York Univ, Dept Chem, Ctr Atmospher Chem, Toronto, ON M3J 1P3, Canada
[2] Environm Canada, Sci & Technol Branch, Atmospher Sci & Technol Directorate, Div Climate Res, Toronto, ON M3H 5T4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Compound specific stable carbon isotope ratio; Phenol; Nitrophenol; Derivatization; Secondary organic aerosols; Photooxidation products; SECONDARY ORGANIC AEROSOL; MASS-SPECTROMETRY; FLOW REACTOR; LOS-ANGELES; TOLUENE; PHOTOOXIDATION; POLLUTANTS; AIR; IDENTIFICATION; SAMPLES;
D O I
10.1016/j.aca.2013.05.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We developed an analytical method for measuring compound-specific stable carbon isotope ratios (delta C-13) of phenols and nitrophenols in filter samples of particulate organic matter. The method was tested on 13 phenols derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA), together with four nonphenolic compounds. The data obtained by our method required two specific corrections for the determination of valid delta C-13 values: (1) for nitro compounds, the routine correction with use of m/z 46 for the contribution of (COO)-C-12-O-17-O-16 molecules) to m/z 45 was modified due to impact of NO2 on the m/z 46 trace, and (2) for the derivatized phenols, measured delta C-13 values were corrected for the shift in delta C-13 due to the addition of carbon atoms from the BSTFA moiety. Analysis of standard-spiked filters showed that overall there was a small compound-dependent bias in the delta C-13 values: the average bias +/- the standard error of the mean of -0.21 +/- 0.1% for the standard compounds tested, except 3-methylcatechol, methylhydroquinone, 4-methyl-2-nitrophenol, and 2,6-dimethyl-4-nitrophenol, whereas the average biases +/- the standard errors of the mean for those were +1.2 +/- 0.3 parts per thousand, +1.2 +/- 0.2 parts per thousand, -1.2 +/- 0.2 parts per thousand, and -1.4 +/- 0.5 parts per thousand, respectively, when the injected mass of a derivatized compound exceeded 15 ngC. In situations where such small biases and uncertainties are acceptable, the method described here could be used to obtain valuable information about delta C-13 values. We also analyzed a real filter sample to demonstrate the practical applicability of the method. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 33 条