Adaptive-perturbation-frequency perturb and observe (P&O) algorithm;
adaptive step size;
dc-dc converters;
maximum power point tracking (MPPT);
photovoltaic (PV);
solar energy;
POWER POINT TRACKING;
PV;
OPTIMIZATION;
ARRAY;
D O I:
10.1109/TPEL.2012.2220158
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
This paper presents a load-current-based maximum power point tracking (MPPT) digital controller with an adaptive-step-size and adaptive-perturbation-frequency algorithm. Only one sensor is needed in the controller circuitry since the MPPT controller is only utilizing the load current information. By utilizing a variable step-size algorithm, the speed, accuracy, and efficiency of the PV system MPPT are improved when compared to the fixed step-size load-current-based algorithm. Furthermore, the proposed adaptive algorithm utilizes a novel variable perturbation frequency scheme which further improves the controller speed. The concept and operation of the load-current adaptive-step-size and adaptive-perturbation-frequency MPPT controller are presented, analyzed, and verified by results obtained from a proof-of-concept experimental prototype.