Cyclic Behavior of Corrugated Double-Skin Composite Walls with Different Aspect Ratios

被引:36
作者
Zhao, Qiuhong [1 ]
Li, Yikang [2 ]
Tian, Ying [3 ]
Li, Zhongxian [1 ]
机构
[1] Tianjin Univ, Sch Civil Engn, Key Lab Coast Civil Struct Safety, Minist Educ, Tianjin 300350, Peoples R China
[2] Tianjin Univ, Sch Civil Engn, Tianjin 300350, Peoples R China
[3] Univ Nevada, Dept Civil & Environm Engn & Construct, Las Vegas, NV 89154 USA
基金
中国国家自然科学基金;
关键词
Composite wall; Corrugated plate; Reinforcing sheaths; Seismic loading; Hysteretic response; PLASTIC-DAMAGE MODEL; SEISMIC BEHAVIOR; CONCRETE; STEEL; PERFORMANCE; STRENGTH; PANELS;
D O I
10.1061/(ASCE)ST.1943-541X.0002783
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Experiments and finite element (FE) simulations were conducted on corrugated double-skin composite (Co-DSC) walls consisting of concrete-filled steel tubes (CFTs) and corrugated steel faceplates connected by tie bolts with concrete infill. Three specimens with different aspect ratios and one additional specimen with reinforcing sheaths at the bottom of CFTs were tested under combined axial and cyclic lateral loads. The specimens experienced a similar damage progress involving steel tubes and faceplates buckling and subsequent steel tube fracture. Both the steel tubes and faceplates experienced significant shear; however, the bending moment was predominately resisted by the CFTs. While the slender walls yielded due to flexure, the squat wall yielded due to both flexure resisted by the steel tubes and shear by the corrugated faceplates. All specimens experienced significant shear deformation and achieved a drift ratio capacity exceeding 1.9% and a ductility ratio greater than 3.2. FE models were developed and validated using the test data. The effects of major parameters, including aspect ratio, axial load ratio, and CFI' bottom reinforcing method, were examined using the validated models. The numerical simulations indicated slender Co-DSC walls were more sensitive to the axial load ratio. Moreover, using sufficiently thick reinforcing sheaths at the CFI' bottom could effectively delay strength degradation. Equations for calculating the lateral strength of Co-DSC were provided. (C) 2020 American Society of Civil Engineers.
引用
收藏
页数:18
相关论文
共 50 条
[21]   Seismic behavior of CFST components for shear walls using double corrugated steel plates [J].
Liao, Xu ;
Li, Xian ;
Li, Wei ;
Su, Rong ;
Chen, Ming .
ENGINEERING STRUCTURES, 2025, 334
[22]   Compressive behavior of double skin composite wall with different plate thicknesses [J].
Qin, Ying ;
Shu, Gan-Ping ;
Zhou, Guan-Gen ;
Han, Jian-Hong .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 157 (297-313) :297-313
[23]   Seismic behavior of double steel plate-HSC composite walls [J].
Chen, Lin ;
Mahmoud, Hussam ;
Tong, Shi-Min ;
Zhou, Yun .
ENGINEERING STRUCTURES, 2015, 102 :1-12
[24]   Sectional strength and design of double-skin composite walls withre-entrant profiled faceplates [J].
Tong, Jing-Zhong ;
Yu, Chao-Qun ;
Zhang, Lei .
THIN-WALLED STRUCTURES, 2021, 158
[25]   Behavior of FRP-HSC-Steel Double-Skin Tubular Columns under Cyclic Axial Compression [J].
Albitar, Mohammad ;
Ozbakkaloglu, Togay ;
Fanggi, Butje Alfonsius Louk .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2015, 19 (02)
[26]   Compressive behaviour of concrete-filled double-skin sections consisting of corrugated plates [J].
Farahi, Mojtaba ;
Heidarpour, Amin ;
Zhao, Xiao-Ling ;
Al-Mahaidi, Riadh .
ENGINEERING STRUCTURES, 2016, 111 :467-477
[27]   Axial compression behavior of double-skin tubular-encased confined-concrete bar columns [J].
Gao, Ruofan ;
Sun, Zhi ;
Liu, Jiaqi ;
Fu, Bing ;
Yuan, Hong .
STRUCTURES, 2025, 76
[28]   Sectional strength design of a double-skin truss-reinforced composite shear wall [J].
Han, Jianhong ;
Shu, Ganping ;
Qin, Ying ;
Zhou, Guangen ;
Zhou, Xiongliang .
THIN-WALLED STRUCTURES, 2024, 195
[29]   Seismic behavior of double-skin composite wall with L-shaped and C-shaped connectors [J].
Chen, Lihua ;
Wang, Shiye ;
Lou, Yu ;
Xia, Dengrong .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 160 :255-270
[30]   Behavior of hybrid FRP-concrete-steel double-skin tubular columns subjected to cyclic axial compression [J].
Yu, T. ;
Zhang, B. ;
Cao, Y. B. ;
Teng, J. G. .
THIN-WALLED STRUCTURES, 2012, 61 :196-203