共 5 条
Loading capacity of CAD/CAM-fabricated anterior feldspathic ceramic crowns bonded to one-piece zirconia implants with different cements
被引:8
|作者:
Nueesch, Reto
[1
]
Conejo, Julian
[2
]
Mante, Francis
[2
]
Fischer, Jens
[3
,4
]
Martin, Sabrina
[4
]
Rohr, Nadja
[3
]
Blatz, Markus B.
[2
]
机构:
[1] Univ Zurich, Ctr Dent Med, Zurich, Switzerland
[2] Univ Penn, Sch Dent Med, Dept Prevent & Restorat Sci, Philadelphia, PA 19104 USA
[3] Univ Ctr Dent Med, Div Dent Mat & Engn, Dept Reconstruct Dent, Basel, Switzerland
[4] VITA Zahnfabrik, Bad Sackingen, Germany
关键词:
CAD/CAM crown;
ceramic implant;
compressive strength;
feldspathic crown;
fracture load;
resin composite cement;
zirconia implant;
SINGLE-TOOTH REPLACEMENT;
FRACTURE-RESISTANCE;
TITANIUM IMPLANTS;
DENTAL IMPLANTS;
BITE FORCE;
RESIN;
SURVIVAL;
RESTORATIONS;
CONVERSION;
REMOVAL;
D O I:
10.1111/clr.13404
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Objective This study evaluated the loading capacity of CAD/CAM-fabricated anterior feldspathic ceramic crowns bonded to one-piece zirconia implants with different cements. Material and methods Fifty one-piece zirconia implants were embedded in epoxy resin. The abutment aspect of one implant was optically scanned and a standardized upper canine was designed with CAD-software. Fifty feldspathic ceramic crowns were milled, polished, and mounted on the implants either without any cement, with a temporary cement or with three different composite resin cements after surface pretreatment as recommended by the manufacturers (n = 10). After storage in distilled water at 37 degrees C for 24 hr, specimens were loaded until fracture on the palatal surface of the crown at an angle of 45 degrees to the long axis of the implant and loads until fracture were detected and compared. Compressive strength of the investigated cement materials was determined. Statistical analyses were done with One-way ANOVA followed by post hoc Fisher LSD test (alpha = 0.05). Results The cements revealed significantly different compressive strength values (temporary cement: 37.1 +/- 7.0 MPa; composite resin cements: 185.8 +/- 21.3, 277.9 +/- 22.1, and 389.0 +/- 13.6 MPa, respectively). Load-at-fracture values had an overall mean value of 237.1 +/- 58.2 N with no significant difference among the composite resin cements (p > 0.05). Fracture load values with the temporary cement or without cement were significantly lower (p < 0.002). Conclusions CAD/CAM-fabricated anterior feldspathic ceramic crowns bonded to one-piece zirconia implants provide sufficient resistance to intraoral forces.
引用
收藏
页码:178 / 186
页数:9
相关论文