ASSESSMENT OF INTRAOCULAR PRESSURE BY APPLANATION AND REBOUND TONOMETRY IN GUINEA PIGS OF DIFFERENT AGES

被引:2
|
作者
Cairo, Marti
Teresa Pena, Maria
Rios, Jose
Melero, Adria
Martorell, Jaume
Leiva, Marta
机构
[1] Univ Autonoma Barcelona, Fdn Hosp Clin Vet, Barcelona, Spain
[2] Univ Autonoma Barcelona, Fac Vet, Dept Med & Cirurgia Anim, Barcelona, Spain
[3] Univ Autonoma Barcelona, Fac Med, Lab Biostat & Epidemiol, Biostat, Bellaterra 08193, Spain
[4] Hosp Clin Barcelona, IDIBAPS, Biostat & Data Management Platform, Barcelona, Spain
关键词
intraocular pressure; eye; laboratory animal; guinea pig; Cavia porcellus; OPHTHALMIC DIAGNOSTIC-TESTS; CIRCADIAN-RHYTHM; REFERENCE VALUES; CAVIA-PORCELLUS; CORNEAL SENSITIVITY; TEAR PRODUCTION; OCULAR GROWTH; DOGS; HORSES; EYE;
D O I
10.1053/j.jepm.2017.10.004
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Fifty-two guinea pigs (Cavia porcellus) with normal ophthalmic examinations were included in this study to determine whether there are differences in the intraocular pressure (IOP) according to age, while assessing the clinical usefulness of 2 different tonometry methods for this species. The animals were divided into 2 groups according to age: young (4 weeks old, 29 animals) and adult (3 to 36 months, 23 animals). Tonometry was performed oculus utro (OU) in the central cornea according to the manufacturer's recommendations. Only measurements with low standard deviation (SD < 5%) were included. Rebound tonometry was performed first OU; following topical anesthesia, applanation tonometry was then performed OU. The time required to obtain an IOP value was recorded for each eye. Descriptive statistics were calculated and Lin Concordance Coefficient (LCC) was performed to describe concordance between methods. Mean TonoVet IOP readings were 8.53 +/- 1.28 mmHg and 13.20 +/- 1.28 mmHg for young and adult animals, respectively (p < 0.05). Tono-Pen VET readings could not be obtained in young animals, but yielded a mean of 10.93 3.61 mmHg in adults. No differences were found between the left and right eyes (p > 0.05) nor between sexes (p > 0.05). TonoVet readings were obtained faster than Tono-Pen VET readings (less than 1 min vs 3.38 +/- 1.27 min, respectively [p < 0.05]). Lin Concordance Coefficient between methods was 0.37 (95% CI: 0.19 to 0.53), documenting a poor concordance between the 2 methods. This study found that normal IOP values are lower in young animals compared with adult animals. Moreover, the results obtained from this investigation demonstrated that TonoVet tonometry is a rapid and well-tolerated procedure when performed on guinea pigs of any age, whereas Tono-Pen VET tonometry is a more time-consuming technique that can only be used on guinea pigs older than 3 months. Copyright 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 50 条
  • [31] Intraocular pressure and tear secretion in Saanen goats with different ages
    Ribeiro, Alexandre Pinto
    Trujillo Piso, Dunia Yisela
    Martinez Padua, Ivan Ricardo
    Silva, Miguel Ladino
    Laus, Jose Luiz
    PESQUISA VETERINARIA BRASILEIRA, 2010, 30 (09): : 798 - 802
  • [32] Evaluation of intraocular pressure in conscious Hermann's tortoises (Testudo hermanni) by means of rebound tonometry
    Selleri, Paolo
    Di Girolamo, Nicola
    Andreani, Valentina
    Guandalini, Adolfo
    D'Anna, Nunzio
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2012, 73 (11) : 1807 - 1812
  • [33] Intraocular Pressure in Captive Black-footed Penguins (Spheniscus demersus) Measured by Rebound Tonometry
    Mercado, Julio A.
    Wirtu, Gemechu
    Beaufrere, Hugues
    Lydick, Dianna
    JOURNAL OF AVIAN MEDICINE AND SURGERY, 2010, 24 (02) : 138 - 141
  • [34] Assessing the Reliability of Intraocular Pressure Measurements Using Rebound Tonometry
    Realini, Tony
    McMillan, Brian
    Gross, Ronald L.
    Devience, Eva
    Balasubramani, Goundappa K.
    JOURNAL OF GLAUCOMA, 2021, 30 (08) : 629 - 633
  • [35] Effects of Topical Latanoprost on Intraocular Pressure and Myopia Progression in Young Guinea Pigs
    El-Nimri, Nevin W.
    Wildsoet, Christine F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (06) : 2644 - 2651
  • [36] Comparison of intraocular pressure in New Zealand White rabbits measured using rebound and applanation tonometers and four different methods of physical restraint
    Okur, S.
    Yanmaz, L. E.
    Senocak, M. G.
    Ersoz, U.
    Goelgeli, A.
    Turgut, F.
    Orhun, O. T.
    Kocaman, Y.
    NEW ZEALAND VETERINARY JOURNAL, 2023, 71 (05) : 251 - 258
  • [37] Comparison of a rebound and an applanation tonometer for measuring intraocular pressure in normal rabbits
    Pereira, Fabiana Quartiero
    Bercht, Bernardo Stefano
    Soares, Mirian Gomes
    Bittencourt da Mota, Mauricio Grillo
    Tadeu Pigatto, Joao Antonio
    VETERINARY OPHTHALMOLOGY, 2011, 14 (05) : 321 - 326
  • [38] Intraocular pressure measurement with Corvis ST in comparison with applanation tonometry and Tomey non-contact tonometry
    Luebke, Jan
    Bryniok, L.
    Neuburger, M.
    Jordan, J. F.
    Boehringer, D.
    Reinhard, T.
    Wecker, T.
    Anton, A.
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (11) : 2517 - 2521
  • [39] Intraocular pressure measurement with Corvis ST in comparison with applanation tonometry and Tomey non-contact tonometry
    Jan Luebke
    L. Bryniok
    M. Neuburger
    J. F. Jordan
    D. Boehringer
    T. Reinhard
    T. Wecker
    A. Anton
    International Ophthalmology, 2019, 39 : 2517 - 2521
  • [40] Intraocular pressure measurements with Goldmann applanation tonometry and dynamic contour tonometry in eyes after IntraLASIK or LASEK
    Shemesh, Gabi
    Soiberman, Uri
    Kurtz, Shimon
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 1967 - 1970