摘要
Objective: The objective of this study was to compare the accuracy of 320-row computed tomography angiography (CTA) with conventional coronary angiography. Methods: Two hundred seventy-four patients with coronary artery disease who received both invasive coronary angiography and 320-row CTA were included. Stenosis of 50% or greater was considered obstructive. Results: In patient-based analysis, accuracy of CTA was 89.4%, with sensitivity of 94.6% and specificity of 54.3%. In segment-based analysis, the overall (4110 segments) accuracy of CTA was 90.7%, with sensitivity of 66.5% and specificity of 95.8%. For the segments with plaques (1191 segments), accuracy of CTA was 80.1%, with sensitivity of 83.5% and specificity of 77.0%. For segments with no plaque (2919 segments), accuracy of CTA was 95.0%, with sensitivity of 0.7% and specificity of 100.0%. For the segments with stents (110 segments), the accuracy of CTA was 86.4%. Conclusions: A 320-row CTA has potential to detect coronary lesions with soft and intermediate plaques.
引用
收藏
页码:646 / 653
页数:8
相关论文
共 19 条
[11]   Assessment of coronary artery calcification in hemodialysis patients using multi-detector spiral CT scan [J].
Nitta, K ;
Akiba, T ;
Suzuki, K ;
Uchida, K ;
Ogawa, T ;
Majima, K ;
Watanabe, RI ;
Aoki, T ;
Nihei, H .
HYPERTENSION RESEARCH, 2004, 27 (08) :527-533
[12]   Patient Acceptance of Noninvasive and Invasive Coronary Angiography [J].
Schoenenberger, Eva ;
Schnapauff, Dirk ;
Teige, Florian ;
Laule, Michael ;
Hamm, Bernd ;
Dewey, Marc .
PLOS ONE, 2007, 2 (02)
[13]   Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography [J].
Schroeder, S ;
Kopp, AF ;
Baumbach, A ;
Meisner, C ;
Kuettner, A ;
Georg, C ;
Ohnesorge, B ;
Herdeg, C ;
Claussen, CD ;
Karsch, KR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) :1430-1435
[14]   Diagnostic value of multislice computed tomography angiography in coronary artery disease: A meta-analysis [J].
Sun, Zhonghua ;
Jiang, Wen .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (02) :279-286
[15]  
Valentin Jack, 2007, Annals of the ICRP, V37, P3
[16]   Performance and efficacy of 320-row computed tomography coronary angiography in patients presenting with acute chest pain: results from a clinical registry [J].
van Velzen, J. E. ;
de Graaf, F. R. ;
Kroft, L. J. ;
de Roos, A. ;
Reiber, J. H. C. ;
Bax, J. J. ;
Jukema, J. W. ;
Schuijf, J. D. ;
Schalij, M. J. ;
van der Wall, E. E. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04) :865-876
[17]   Diagnostic Accuracy of Computed Tomography Angiography in Patients After Bypass Grafting Comparison With Invasive Coronary Angiography [J].
Weustink, Annick C. ;
Nieman, Koen ;
Pugliese, Fransesca ;
Mollet, Nico R. ;
Meijboom, Bob W. ;
van Mieghem, Carlos ;
ten Kate, Gert-Jan ;
Cademartiri, Filippo ;
Krestin, Gabriel P. ;
de Feyter, Pim J. .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (07) :816-824
[18]   Estimation of global and regional cardiac function using 64-slice computed tomography: A comparison study with echocardiography, gated-SPECT and cardiovascular magnetic resonance [J].
Wu, Yen-Wen ;
Tadamura, Eiji ;
Yamamuro, Masaki ;
Kanao, Shotaro ;
Okayama, Satoshi ;
Ozasa, Neiko ;
Toma, Masanao ;
Kimura, Takeshi ;
Komeda, Masashi ;
Togashi, Kaori .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 128 (01) :69-76
[19]   EFFECT OF CORONARY-ARTERY BYPASS GRAFT-SURGERY ON SURVIVAL - OVERVIEW OF 10-YEAR RESULTS FROM RANDOMIZED TRIALS BY THE CORONARY-ARTERY BYPASS GRAFT-SURGERY TRIALISTS COLLABORATION [J].
YUSUF, S ;
ZUCKER, D ;
PEDUZZI, P ;
FISHER, LD ;
TAKARO, T ;
KENNEDY, JW ;
DAVIS, K ;
KILLIP, T ;
PASSAMANI, E ;
NORRIS, R ;
MORRIS, C ;
MATHUR, V ;
VARNAUSKAS, E ;
CHALMERS, TC .
LANCET, 1994, 344 (8922) :563-570