Newly Designed Amperometric Biosensor for Hydrogen Peroxide and Glucose Based on Vanadium Sulfide Nanoparticles

被引:47
作者
Sarkar, Arpita [1 ]
Ghosh, Abhisek Brata [1 ]
Saha, Namrata [1 ]
Bhadu, Gopala Ram [2 ]
Adhikary, Bibhutosh [1 ]
机构
[1] Indian Inst Engn Sci & Technol, Dept Chem, Howrah 711103, W Bengal, India
[2] Cent Salt & Marine Chem Res Inst, Dept Analyt Sci, Gijubhai Badheka Marg, Bhavnagar 364002, Gujarat, India
来源
ACS APPLIED NANO MATERIALS | 2018年 / 1卷 / 03期
关键词
VS2; NPs; fabrication; modified electrode; biosensing; amperometric biosensor; DIRECT ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL SENSING PLATFORM; REDUCED GRAPHENE OXIDE; NONENZYMATIC DETECTION; GOLD NANOPARTICLES; FLUORESCENT-PROBE; CARBON; SENSOR; ELECTRODE; REDUCTION;
D O I
10.1021/acsanm.8b00076
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In the present work, we describe a facile, green, and template-free solvothermal fabrication of vanadium sulfide (VS2) nanoparticles (NPs) and their application for the electrochemical detection of hydrogen peroxide (H2O2) and glucose. The morphology and composition of as-prepared samples were well-characterized by powder X-ray diffraction, energy-dispersive spectroscopy, transmission electron microscopy, scanning electron microscopy, UV-vis spectroscopy, and Brunauer-Emmett-Teller surface area measurement. Because of their interesting electrochemical responses toward H2O2, a novel nonenzymatic electrochemical sensor for H2O2 and glucose detection has been proposed based on a VS2 NP-modified glassy carbon electrode. The modified electrode showed an excellent electrochemical performance for the selective and sensitive nonenzymatic detection of H2O2 in a broad concentration range of 0.5 mu M to 3.0 mM, with a wide linear range of 0.5 mu M to 2.5 mM and a lower detection limit of 0.224 mu M. The newly developed sensor also displayed high sensitivity (41.96 mu A mM(-1)) toward the detection of glucose with a broad linear range of 0.5 mu M to 3 mM. The as-fabricated sensor also showed very high sensitivity, excellent reusability, long-term stability, and negligible interference ability. Moreover, the synthesized NPs were applied for H2O2 and glucose detection in real samples, signifying their potential application in routine H2O2 and glucose analysis. The present study reveals that as-prepared VS2 NPs are promising for electrochemical H2O2 and glucose sensing and other biological applications.
引用
收藏
页码:1339 / 1347
页数:17
相关论文
共 50 条
  • [41] Gold nanoparticles-decorated silver-bipyridine nanobelts for the construction of mediatorless hydrogen peroxide biosensor
    Boujakhrout, Abderrahmane
    Diez, Paula
    Sanchez, Alfredo
    Martinez-Ruiz, Paloma
    Pingarron, Jose M.
    Villalonga, Reynaldo
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2016, 482 : 105 - 111
  • [42] Novel flexible bifunctional amperometric biosensor based on laser engraved porous graphene array electrodes: Highly sensitive electrochemical determination of hydrogen peroxide and glucose
    Lu, Zhiwei
    Wu, Lan
    Dai, Xianxiang
    Wang, Yanying
    Sun, Mengmeng
    Zhou, Cailong
    Du, Haijun
    Rao, Hanbing
    JOURNAL OF HAZARDOUS MATERIALS, 2021, 402
  • [43] An Amperometric Glucose Biosensor based on Pd-Pt Nanodendrites and Chitosan Matrix
    Sun, XiaoBin
    Ma, ZhanFang
    ADVANCED RESEARCH ON BIOCHEMICAL MATERIALS AND NANOTECHNOLOGY APPLICATION, 2013, 643 : 162 - +
  • [44] Gold foil-based biosensor for the determination of hydrogen peroxide
    Narayanan, J. Shankara
    Slaughter, Gymama
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 2885 - 2888
  • [45] Amperometric hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase by carbon-coated iron nanoparticles in combination with chitosan and cross-linking of glutaraldehyde
    Lai, Guo-Song
    Zhang, Hai-Li
    Han, De-Yan
    MICROCHIMICA ACTA, 2009, 165 (1-2) : 159 - 165
  • [46] An amperometric biosensor for the detection of hydrogen peroxide released from human breast cancer cells
    Zhao, Jing
    Yan, Yalin
    Zhu, Li
    Li, Xiaoxi
    Li, Genxi
    BIOSENSORS & BIOELECTRONICS, 2013, 41 : 815 - 819
  • [47] Amperometric hydrogen peroxide biosensor based on the immobilization of HRP on DNA-silver nanohybrids and PDDA-protected gold nanoparticles
    Ma, Liping
    Yuan, Ruo
    Chai, Yaqin
    Chen, Shihong
    JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2009, 56 (04) : 215 - 220
  • [48] Recombinant Mn Peroxidase from Corn Grain Has an Excellent Electrocatalytic Effect in a Designed Amperometric Biosensor To Detect Hydrogen Peroxide at Low Concentrations
    Izadyar, Anahita
    Tran, Uyen
    Seok, Ilwoo
    Hood, Elizabeth E.
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2019, 7 (24): : 19434 - 19441
  • [49] Disposable amperometric biosensor based on nanostructured bacteriophages for glucose detection
    Kang, Yu Ri
    Hwang, Kyung Hoon
    Kim, Ju Hwan
    Nam, Chang Hoon
    Kim, Soo Won
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (10)
  • [50] Amperometric glucose biosensor based on lipid film
    Wu, ZY
    Wang, BQ
    Dong, SJ
    Wang, EK
    BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4) : 143 - 147