Newly Designed Amperometric Biosensor for Hydrogen Peroxide and Glucose Based on Vanadium Sulfide Nanoparticles

被引:47
作者
Sarkar, Arpita [1 ]
Ghosh, Abhisek Brata [1 ]
Saha, Namrata [1 ]
Bhadu, Gopala Ram [2 ]
Adhikary, Bibhutosh [1 ]
机构
[1] Indian Inst Engn Sci & Technol, Dept Chem, Howrah 711103, W Bengal, India
[2] Cent Salt & Marine Chem Res Inst, Dept Analyt Sci, Gijubhai Badheka Marg, Bhavnagar 364002, Gujarat, India
来源
ACS APPLIED NANO MATERIALS | 2018年 / 1卷 / 03期
关键词
VS2; NPs; fabrication; modified electrode; biosensing; amperometric biosensor; DIRECT ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL SENSING PLATFORM; REDUCED GRAPHENE OXIDE; NONENZYMATIC DETECTION; GOLD NANOPARTICLES; FLUORESCENT-PROBE; CARBON; SENSOR; ELECTRODE; REDUCTION;
D O I
10.1021/acsanm.8b00076
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In the present work, we describe a facile, green, and template-free solvothermal fabrication of vanadium sulfide (VS2) nanoparticles (NPs) and their application for the electrochemical detection of hydrogen peroxide (H2O2) and glucose. The morphology and composition of as-prepared samples were well-characterized by powder X-ray diffraction, energy-dispersive spectroscopy, transmission electron microscopy, scanning electron microscopy, UV-vis spectroscopy, and Brunauer-Emmett-Teller surface area measurement. Because of their interesting electrochemical responses toward H2O2, a novel nonenzymatic electrochemical sensor for H2O2 and glucose detection has been proposed based on a VS2 NP-modified glassy carbon electrode. The modified electrode showed an excellent electrochemical performance for the selective and sensitive nonenzymatic detection of H2O2 in a broad concentration range of 0.5 mu M to 3.0 mM, with a wide linear range of 0.5 mu M to 2.5 mM and a lower detection limit of 0.224 mu M. The newly developed sensor also displayed high sensitivity (41.96 mu A mM(-1)) toward the detection of glucose with a broad linear range of 0.5 mu M to 3 mM. The as-fabricated sensor also showed very high sensitivity, excellent reusability, long-term stability, and negligible interference ability. Moreover, the synthesized NPs were applied for H2O2 and glucose detection in real samples, signifying their potential application in routine H2O2 and glucose analysis. The present study reveals that as-prepared VS2 NPs are promising for electrochemical H2O2 and glucose sensing and other biological applications.
引用
收藏
页码:1339 / 1347
页数:17
相关论文
共 50 条
  • [11] Novel amperometric glucose biosensor based on MXene nanocomposite
    Rakhi, R. B.
    Nayuk, Pranati
    Xia, Chuan
    Alshareef, Husam N.
    SCIENTIFIC REPORTS, 2016, 6
  • [12] Amperometric hydrogen peroxide biosensor based on the immobilization of heme proteins on gold nanoparticles-bacteria cellulose nanofibers nanocomposite
    Wang, Wei
    Zhang, Tai-Ji
    Zhang, De-Wen
    Li, Hong-Yi
    Ma, Yu-Rong
    Qi, Li-Min
    Zhou, Ying-Lin
    Zhang, Xin-Xiang
    TALANTA, 2011, 84 (01) : 71 - 77
  • [13] Amperometric hydrogen peroxide biosensor based on covalent immobilization of horseradish peroxidase on ferrocene containing polymeric mediator
    Senel, Mehmet
    Cevik, Emre
    Abasiyanik, M. Fatih
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (01) : 444 - 450
  • [14] Amperometric biosensor for hydrogen peroxide based on immobilisation of haemoglobin on mesoporous zirconia
    Liu, Changhua
    Teng, Yingli
    Xu, Jing
    Yang, Yajuan
    Wu, Zongfang
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2011, 91 (14) : 1367 - 1379
  • [15] A Review on Glucose and Hydrogen Peroxide Biosensor Based on Modified Electrode Included Silver Nanoparticles
    Rad, Ali Shokuhi
    Mirabi, Ali
    Binaian, Ehsan
    Tayebi, Habibollah
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (08): : 3671 - 3683
  • [16] Immobilizing Pt nanoparticles and chitosan hybrid film on polyaniline naofibers membrane for an amperometric hydrogen peroxide biosensor
    Chen, Shihong
    Fu, Ping
    Yin, Bing
    Yuan, Ruo
    Chai, Yaqin
    Xiang, Yun
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2011, 34 (06) : 711 - 719
  • [17] A Single ZnO Nanofiber-Based Highly Sensitive Amperometric Glucose Biosensor
    Ahmad, Mashkoor
    Pan, Caofeng
    Luo, Zhixiang
    Zhu, Jing
    JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (20) : 9308 - 9313
  • [18] Hydrogen Peroxide Biosensor Based on Carbon Supported Ultrafine Silver Nanoparticles
    Wang Yi-Chen
    Jiang Xiu-E
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (05) : 689 - 694
  • [19] Durable Hydrogen Peroxide Biosensors Based on Polypyrrole-Decorated Platinum/Palladium Bimetallic Nanoparticles
    Zheng, Junping
    Liu, Yu
    Ye, Cheng
    Liu, Yang
    Zhang, Zhigang
    Yin, Mingzhu
    Gao, Qinghua
    Liu, Hongtao
    ACS APPLIED NANO MATERIALS, 2021, 4 (08) : 8116 - 8125
  • [20] Determination of hydrogen peroxide with an enzymeless amperometric sensor based on poly(vinylferrocene)-supported Ag nanoparticles
    Celebi, Mutlu Sonmez
    Ozturk, Kubra
    Dumangoz, Mehmet
    Kuralay, Filiz
    TURKISH JOURNAL OF CHEMISTRY, 2018, 42 (06) : 1755 - 1767