Newly Designed Amperometric Biosensor for Hydrogen Peroxide and Glucose Based on Vanadium Sulfide Nanoparticles

被引:47
作者
Sarkar, Arpita [1 ]
Ghosh, Abhisek Brata [1 ]
Saha, Namrata [1 ]
Bhadu, Gopala Ram [2 ]
Adhikary, Bibhutosh [1 ]
机构
[1] Indian Inst Engn Sci & Technol, Dept Chem, Howrah 711103, W Bengal, India
[2] Cent Salt & Marine Chem Res Inst, Dept Analyt Sci, Gijubhai Badheka Marg, Bhavnagar 364002, Gujarat, India
来源
ACS APPLIED NANO MATERIALS | 2018年 / 1卷 / 03期
关键词
VS2; NPs; fabrication; modified electrode; biosensing; amperometric biosensor; DIRECT ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL SENSING PLATFORM; REDUCED GRAPHENE OXIDE; NONENZYMATIC DETECTION; GOLD NANOPARTICLES; FLUORESCENT-PROBE; CARBON; SENSOR; ELECTRODE; REDUCTION;
D O I
10.1021/acsanm.8b00076
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In the present work, we describe a facile, green, and template-free solvothermal fabrication of vanadium sulfide (VS2) nanoparticles (NPs) and their application for the electrochemical detection of hydrogen peroxide (H2O2) and glucose. The morphology and composition of as-prepared samples were well-characterized by powder X-ray diffraction, energy-dispersive spectroscopy, transmission electron microscopy, scanning electron microscopy, UV-vis spectroscopy, and Brunauer-Emmett-Teller surface area measurement. Because of their interesting electrochemical responses toward H2O2, a novel nonenzymatic electrochemical sensor for H2O2 and glucose detection has been proposed based on a VS2 NP-modified glassy carbon electrode. The modified electrode showed an excellent electrochemical performance for the selective and sensitive nonenzymatic detection of H2O2 in a broad concentration range of 0.5 mu M to 3.0 mM, with a wide linear range of 0.5 mu M to 2.5 mM and a lower detection limit of 0.224 mu M. The newly developed sensor also displayed high sensitivity (41.96 mu A mM(-1)) toward the detection of glucose with a broad linear range of 0.5 mu M to 3 mM. The as-fabricated sensor also showed very high sensitivity, excellent reusability, long-term stability, and negligible interference ability. Moreover, the synthesized NPs were applied for H2O2 and glucose detection in real samples, signifying their potential application in routine H2O2 and glucose analysis. The present study reveals that as-prepared VS2 NPs are promising for electrochemical H2O2 and glucose sensing and other biological applications.
引用
收藏
页码:1339 / 1347
页数:17
相关论文
共 50 条
  • [1] A novel amperometric biosensor for hydrogen peroxide and glucose based on cuprous sulfide nanoplates
    Maji, Swarup Kumar
    Dutta, Amit Kumar
    Bhadu, Gopala Ram
    Paul, Parimal
    Mondal, Anup
    Adhikary, Bibhutosh
    JOURNAL OF MATERIALS CHEMISTRY B, 2013, 1 (33) : 4127 - 4134
  • [2] Amperometric Hydrogen Peroxide Biosensor Based on Multiwall Carbon Nanotubes and Cadmium Sulfide Quantum Dots
    Zhang Jin-lei
    Tan Xue-cai
    Zhao Dan-dan
    Tan Sheng-wei
    Huang Zeng-wei
    Mi Yan
    Huang Zai-yin
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2010, 26 (04) : 541 - 545
  • [3] Amperometric hydrogen peroxide biosensor based on covalently immobilizing thionine as a mediator
    Ma, Liping
    Yuan, Ruo
    Chai, Yaqin
    Chen, Shihong
    Ling, Shujuan
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2009, 32 (04) : 537 - 544
  • [4] Non-Enzymatic Amperometric Sensing of Hydrogen Peroxide Based on Vanadium Pentoxide Nanostructures
    Ghanei-Motlagh, Masoud
    Taher, Mohammad Ali
    Fayazi, Maryam
    Baghayeri, Mehdi
    Hosseinifar, AbduRahman
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (06) : B367 - B372
  • [5] Fabrication of cuprous sulfide nanorods supported on copper foam for nonenzymatic amperometric determination of glucose and hydrogen peroxide
    Lu, Wangdong
    Sun, Yujing
    Dai, Haichao
    Ni, Pengjuan
    Jiang, Shu
    Wang, Yilin
    Li, Zhen
    Li, Zhuang
    RSC ADVANCES, 2016, 6 (93): : 90732 - 90738
  • [6] Amperometric Glucose Biosensor Based on Pt-Pd Nanoparticles Supported by Reduced Graphene Oxide and Integrated with Glucose Oxidase
    Hossain, M. F.
    Park, Jae Y.
    ELECTROANALYSIS, 2014, 26 (05) : 940 - 951
  • [7] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Wang, Qingxia
    Zhang, Haili
    Wu, Yiwei
    Yu, Aimin
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 279 - 285
  • [8] Amperometric hydrogen peroxide biosensor based on cobalt ferrite-chitosan nanocomposite
    Yardimci, Feyza S.
    Senel, Mehmet
    Baykal, Abdulhadi
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (02): : 269 - 275
  • [9] Hydrogen peroxide and glucose biosensor based on silver nanowires synthesized by polyol process
    Yang, Xuejuan
    Bai, Jing
    Wang, Yinhu
    Jiang, Xiue
    He, Xiaoying
    ANALYST, 2012, 137 (18) : 4362 - 4367
  • [10] Amperometric hydrogen peroxide and glucose biosensor based on NiFe2/ordered mesoporous carbon nanocomposites
    Xiang, Dong
    Yin, Longwei
    Ma, Jingyun
    Guo, Enyan
    Li, Qun
    Li, Zhaoqiang
    Liu, Kegao
    ANALYST, 2015, 140 (02) : 644 - 653