Sinusoidal Siemens star spatial frequency response measurement errors due to misidentified target centers

被引:14
作者
Birch, Gabriel C. [1 ]
Griffin, John C. [1 ]
机构
[1] Sandia Natl Labs, Albuquerque, NM 87185 USA
关键词
spatial frequency response; modulation transfer function; resolution; image quality evaluation; Siemens star;
D O I
10.1117/1.OE.54.7.074104
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Numerous methods are available to measure the spatial frequency response (SFR) of an optical system. A recent change to the ISO 12233 photography resolution standard includes a sinusoidal Siemens star test target. We take the sinusoidal Siemens star proposed by the ISO 12233 standard, measure system SFR, and perform an analysis of errors induced by incorrectly identifying the center of a test target. We show a closed-form solution for the radial profile intensity measurement given an incorrectly determined center and describe how this error reduces the measured SFR of the system. Using the closed-form solution, we propose a two-step process by which test target centers are corrected and the measured SFR is restored to the nominal, correctly centered values. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:8
相关论文
共 12 条
[1]   Differences of digital camera resolution metrology to describe noise reduction artifacts [J].
Artmann, Uwe ;
Wueller, Dietmar .
IMAGE QUALITY AND SYSTEM PERFORMANCE VII, 2010, 7529
[2]   Evaluating the quality of EDOF in camera phones [J].
Atanassov, Kalin ;
Goma, Sergio .
IMAGE QUALITY AND SYSTEM PERFORMANCE VII, 2010, 7529
[3]   Iterative reconstruction of projection images from a microlens-based optical detector [J].
Cao, Liji ;
Peter, Joerg .
OPTICS EXPRESS, 2011, 19 (13) :11932-11943
[4]   Fiber-optic raster scanning two-photon endomicroscope using a tubular piezoelectric actuator [J].
Do, Dukho ;
Yoo, Hongki ;
Gweon, Dae-Gab .
JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (06)
[5]   Performance assessment of compressive sensing imaging [J].
Du Bosq, Todd W. ;
Haefner, David P. ;
Preece, Bradley L. .
INFRARED IMAGING SYSTEMS: DESIGN, ANALYSIS, MODELING, AND TESTING XXV, 2014, 9071
[6]  
Duan YN, 2011, 2011 INTERNATIONAL CONFERENCE ON ELECTRONICS, COMMUNICATIONS AND CONTROL (ICECC), P202, DOI 10.1109/ICECC.2011.6067687
[7]  
I. S. O. International, 2014, ISO122332014
[8]   Digital camera resolution measurement using sinusoidal siemens stars [J].
Loebich, Christian ;
Wueller, Dietmar ;
Klingen, Bruno ;
Jaeger, Anke .
DIGITAL PHOTOGRAPHY III, 2007, 6502
[9]   Evaluation of mobile phone camera benchmarking using objective camera speed and image quality metrics [J].
Peltoketo, Veli-Tapani .
JOURNAL OF ELECTRONIC IMAGING, 2014, 23 (06)
[10]   A quantitative performance measure for a clinical evaluation of comb structure removal algorithms in flexible endoscopy [J].
Rupp, Stephan .
MEDICAL IMAGING 2008: IMAGE PROCESSING, PTS 1-3, 2008, 6914