Invasive and non-invasive fractional flow reserve index in validation of hemodynamic severity of intracoronary lesions

被引:9
作者
Wasilewski, Jaroslaw [1 ]
Mirota, Kryspin [2 ]
Hawranek, Michal [1 ]
Polonski, Lech [1 ]
机构
[1] Med Univ Silesia, Silesian Ctr Heart Dis, Dept Cardiol 3, Zabrze, Poland
[2] Univ Bielsko Biala, Bielsko Biala, Poland
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2013年 / 9卷 / 02期
关键词
fractional flow reserve; computational fluid dynamics; PERCUTANEOUS CORONARY INTERVENTION; COMPUTED TOMOGRAPHIC ANGIOGRAMS; OPTIMAL MEDICAL THERAPY; CARDIAC SYNDROME-X; FOLLOW-UP; DIAGNOSTIC PERFORMANCE; FUNCTIONAL SEVERITY; STENT IMPLANTATION; ARTERY STENOSES; BYPASS-SURGERY;
D O I
10.5114/pwki.2013.35452
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This review discusses visual and functional evaluation of the hemodynamic significance of the degree of stenosis in coronary angiography, with respect to the indications for revascularization. The concept of the coronary flow reserve is defined, and the theoretical assumptions of the invasive measurement of the fractional flow reserve (FFR) are presented. In the following part, the publication describes the basic steps of numerical stimulations in terms of computational fluid dynamics (CFD) in calculating the fractional flow reserve based on computed tomography (CT) coronary angiography (FFRCT). The numerical FFRCT estimation in correlation with invasive measurements, as well as benefits deriving from FFRCT in the diagnosis of coronary artery disease, is presented in the example of the multicentre prospective DISCOVER-FLOW trial and the DeFACTO project. The CDF method enables to obtain hemodynamic significance of stenosis solely from the coronary anatomy vizualized by CT angiography. The calculation of FFRCT increases the diagnostic reliability of coronary flow reserve estimations. It contributes to the improvement in patients' qualification for contrast coronarography. If the accuracy of FFRCT is confirmed in clinical practice, and the time required for computational processing is shortened, it may turn out that the algorithms of coronary heart disease diagnosis will be verified and it will be to a greater extent based on the CT results.
引用
收藏
页码:160 / 169
页数:10
相关论文
共 74 条
[41]   Rationale and design of the DeFACTO (Determination of Fractional Flow Reserve by Anatomic Computed Tomographic Angiography) study [J].
Min, James K. ;
Berman, Daniel S. ;
Budoff, Matthew J. ;
Jaffer, Farouc A. ;
Leipsic, Jonathon ;
Leon, Martin B. ;
Mancini, G. B. John ;
Mauri, Laura ;
Schwartz, Robert S. ;
Shaw, Leslee J. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (05) :301-309
[42]  
MIN JK, 2012, JAMA-J AM MED ASSOC, V26, P1237
[43]   Long-Term Follow-Up After Fractional Flow Reserve-Guided Treatment Strategy in Patients With an Isolated Proximal Left Anterior Descending Coronary Aden, Stenosis [J].
Muller, Olivier ;
Mangiacapra, Fabio ;
Ntalianis, Argyrios ;
Verhamme, Katia M. C. ;
Trana, Catalina ;
Hamilos, Michalis ;
Bartunek, Jozef ;
Vanderheyden, Marc ;
Wyffels, Eric ;
Heyndrickx, Guy R. ;
van Rooij, Frank J. A. ;
Witteman, Jacqueline C. M. ;
Hofman, Albert ;
Wijns, William ;
Barbato, Emanuele ;
De Bruyne, Bernard .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (11) :1175-1182
[44]   Relation of Fractional Flow Reserve After Drug-Eluting Stent Implantation to One-Year Outcomes [J].
Nam, Chang-Wook ;
Hur, Seung-Ho ;
Cho, Yun-Kyeong ;
Park, Hyoung-Seob ;
Yoon, Hyuck-Jun ;
Kim, Hyungseop ;
Chung, In-Sung ;
Kim, Yoon-Nyun ;
Kim, Kwon-Bae ;
Doh, Joon-Hyung ;
Koo, Bon-Kwon ;
Tahk, Seung-Jea ;
Fearon, William F. .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (12) :1763-1767
[45]   Influence of coronary collateral flow on coronary diagnostic parameters: An in vitro study [J].
Peelukhana, Srikara Viswanath ;
Back, Lloyd H. ;
Banerjee, Rupak K. .
JOURNAL OF BIOMECHANICS, 2009, 42 (16) :2753-2759
[46]   A NUMERICAL-CALCULATION OF FLOW IN A CURVED TUBE MODEL OF THE LEFT MAIN CORONARY-ARTERY [J].
PERKTOLD, K ;
NEREM, RM ;
PETER, RO .
JOURNAL OF BIOMECHANICS, 1991, 24 (3-4) :175-189
[47]   Coronary thermodilution to assess flow reserve - Validation in humans [J].
Pijls, NHJ ;
De Bruyne, B ;
Smith, L ;
Aarnoudse, W ;
Barbato, E ;
Bartunek, J ;
Bech, GJW ;
Van de Vosse, F .
CIRCULATION, 2002, 105 (21) :2482-2486
[48]   Coronary pressure measurement after stenting predicts adverse events at follow-up - A multicenter registry [J].
Pijls, NHJ ;
Klauss, V ;
Siebert, U ;
Powers, E ;
Takazawa, K ;
Fearon, WF ;
Escaned, J ;
Tsurumi, Y ;
Akasaka, T ;
Samady, H ;
De Bruyne, B .
CIRCULATION, 2002, 105 (25) :2950-2954
[49]   FRACTIONAL FLOW RESERVE - A USEFUL INDEX TO EVALUATE THE INFLUENCE OF AN EPICARDIAL CORONARY STENOSIS ON MYOCARDIAL BLOOD-FLOW [J].
PIJLS, NHJ ;
VANGELDER, B ;
VANDERVOORT, P ;
PEELS, K ;
BRACKE, FALE ;
BONNIER, HJRM ;
ELGAMAL, MIH .
CIRCULATION, 1995, 92 (11) :3183-3193
[50]  
Pijls NHJ, 2000, CATHETER CARDIO INTE, V49, P1