Effects of operating conditions on selectivity of a plasma fractionator in double filtration plasmapheresis

被引:3
作者
Mineshima, M
Yokoi, R
Horibe, K
Eguchi, K
Kaneko, I
Agishi, T
Akiba, T
机构
[1] Tokyo Med Univ, Kidney Ctr, Div Blood Purificat, Tokyo, Japan
[2] Itabashi Cent Hosp, Blood Purificat Ctr, Tokyo, Japan
来源
THERAPEUTIC APHERESIS | 2001年 / 5卷 / 06期
关键词
double filtration plasmapheresis; plasma fractionator; selectivity; operating conditions; rate-constant filtration experiment; membrane fouling;
D O I
10.1046/j.1526-0968.2001.00391.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In a typical double filtration plasmapheresis treatment, plasma fractionation between albumin and some immunoglobulins associated with toxins is limited because none of the currently available plasma fractionators has a strict cutoff property for these proteins. Selectivity of immunoglobulins over albumin depends not only on the cutoff properties of the membrane but on the operating conditions such as the flow rate of the supplied plasma (Q(P)) and retained plasma to be discarded (Q(D)) in the plasma fractionator. We carried out an in vitro study using human plasma harvested by single plasma exchange treatments to assess the selectivity of a plasma fractionator, Evaflux 2A-F (Kawasumi Laboratories, Inc., Tokyo, Japan), under various operating conditions. The results of rate-constant filtration experiments showed that the concentrations in the feed tank and the sieving coefficient (SC) values of every protein were decreased slightly within 2 h after the start of the experiment because of membrane trapping, adsorption, and/or plugging. The time-averaged SC value of albumin increased with flow rate ratio (Q(P)/Q(D)) due to increasing filtration fraction (FF), but relative removal efficiency (m(D)/m(P)*) for albumin decreased with Q(P)/Q(D) due to decreasing Q(D). For immunoglobulins, on the other hand, the SC values were almost unchanged, and the m(D)/m(P)* values increased with Q(P)/Q(D) due to an increase in FF. Both increasing Q(P) and decreasing Q(D) are effective means of improving selectivity between these proteins in the plasma fractionator. Membrane fouling is, however, obvious beyond a Q(P)/Q(D) value that is thought to be a critical point. Operation should be conducted below the critical Q(P)/Q(D) value, which depends on the patient's plasma components and the cutoff property of the membrane.
引用
收藏
页码:444 / 448
页数:5
相关论文
共 12 条
[1]  
AGISHI T, 1980, T AM SOC ART INT ORG, V26, P406
[2]  
BUSNACH G, 1988, INT J ARTIF ORGANS, V11, P493
[3]  
Charcosset C, 1990, ASAIO Trans, V36, pM594
[4]   DYNAMIC FILTRATION OF BLOOD - A NEW CONCEPT FOR ENHANCING PLASMA FILTRATION [J].
DING, L ;
LAURENT, JM ;
JAFFRIN, MY .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (06) :365-370
[5]   ALBUMIN RECOVERY ENHANCEMENT IN MEMBRANE PLASMA FRACTIONATION USING PULSATILE FLOW [J].
DING, L ;
CHARCOSSET, C ;
JAFFRIN, MY .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (01) :61-65
[6]   ANALYTICAL COMPARISON OF SINGLE-PASS AND DEAD-END OPERATION IN CASCADE FILTRATION PLASMAPHERESIS [J].
LYSAGHT, MJ ;
SAMTLEBEN, W ;
SCHMIDT, B ;
GURLAND, HJ .
ARTIFICIAL ORGANS, 1984, 8 (04) :481-487
[7]   EFFECT OF MEMBRANE TRAPPING IN PLASMA FRACTIONATOR ON SEPARATIVE CHARACTERISTICS [J].
MINESHIMA, M ;
AGISHI, T ;
HASUO, Y ;
KANEKO, I ;
ERA, K ;
OTA, K .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1988, 11 (03) :191-194
[8]   OPTIMUM ALBUMIN CONCENTRATION OF SUPPLEMENTATION FLUID FOR DOUBLE FILTRATION PLASMAPHERESIS [J].
MINESHIMA, M ;
AGISHI, T ;
HASUO, Y ;
ERA, K ;
SUZUKI, T ;
TERAOKA, S ;
OTA, K .
ARTIFICIAL ORGANS, 1992, 16 (05) :510-513
[9]  
Mineshima M., 1996, Japanese Journal of Artificial Organs, V25, P102
[10]   Continuous monitoring of blood volume in double filtration plasmapheresis [J].
Mineshima, M ;
Eguchi, K ;
Horibe, K ;
Yokoi, R ;
Kaneko, I ;
Kimata, N ;
Sanaka, T ;
Nihei, H ;
Agishi, T .
ASAIO JOURNAL, 1998, 44 (05) :M465-M469