Nanocolloidal albumin-IRDye 800CW: a near-infrared fluorescent tracer with optimal retention in the sentinel lymph node

被引:31
作者
Heuveling, Derrek A. [1 ]
Visser, Gerard W. M. [2 ]
de Groot, Mattijs [3 ]
de Boer, Johannes F. [3 ]
Baclayon, Marian [3 ]
Roos, Wouter H. [3 ]
Wuite, Gijs J. L. [3 ]
Leemans, C. Rene [1 ]
de Bree, Remco [1 ]
van Dongen, Guus A. M. S. [1 ]
机构
[1] Vrije Univ Amsterdam, Dept Otolaryngol Head & Neck Surg, Med Ctr, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Dept Nucl Med & PET Res, Med Ctr, NL-1007 MB Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Dept Phys & Astron, NL-1007 MB Amsterdam, Netherlands
关键词
Nanocolloidal albumin; IRDye; 800CW; ICG; Sentinel lymph node; Near-infrared fluorescence; Quantum yield; INDOCYANINE GREEN FLUORESCENCE; ATOMIC-FORCE MICROSCOPE; BREAST-CANCER; NECK-CANCER; MULTICENTER TRIAL; HEAD; BIOPSY; CARCINOMA;
D O I
10.1007/s00259-012-2080-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose At present, the only approved fluorescent tracer for clinical near-infrared fluorescence-guided sentinel node (SN) detection is indocyanine green (ICG), but the use of this tracer is limited due to its poor retention in the SN resulting in the detection of higher tier nodes. We describe the development and characterization of a next-generation fluorescent tracer, nanocolloidal albumin-IRDye 800CW that has optimal properties for clinical SN detection Methods The fluorescent dye IRDye 800CW was covalently coupled to colloidal human serum albumin (HSA) particles present in the labelling kit Nanocoll in a manner compliant with current Good Manufacturing Practice. Characterization of nanocolloidal albumin-IRDye 800CW included determination of conjugation efficiency, purity, stability and particle size. Quantum yield was determined in serum and compared to that of ICG. For in vivo evaluation a lymphogenic metastatic tumour model in rabbits was used. Fluorescence imaging was performed directly after peritumoral injection of nanocolloidal albumin-IRDye 800CW or the reference ICG/HSA (i.e. ICG mixed with HSA), and was repeated after 24 h, after which fluorescent lymph nodes were excised. Results Conjugation of IRDye 800CW to nanocolloidal albumin was always about 50% efficient and resulted in a stable and pure product without affecting the particle size of the nanocolloidal albumin. The quantum yield of nanocolloidal albumin-IRDye 800CW was similar to that of ICG. In vivo evaluation revealed noninvasive detection of the SN within 5 min of injection of either nanocolloidal albumin-IRDye 800CW or ICG/HSA. No decrease in the fluorescence signal from SN was observed 24 h after injection of the nanocolloidal albumin-IRDye 800CW, while a strong decrease or complete disappearance of the fluorescence signal was seen 24 h after injection of ICG/HSA. Fluorescence-guided SN biopsy was very easy. Conclusion Nanocolloidal albumin-IRDye 800CW is a promising fluorescent tracer with optimal kinetic features for SN detection.
引用
收藏
页码:1161 / 1168
页数:8
相关论文
共 30 条
[1]   Indocyanine green fluorescence imaging system for sentinel lymph node biopsies in early breast cancer patients [J].
Abe, Hajime ;
Mori, Tsuyoshi ;
Umeda, Tomoko ;
Tanaka, Makiko ;
Kawai, Yuki ;
Shimizu, Tomoharu ;
Cho, Hirotomi ;
Kubota, Yoshihiro ;
Kurumi, Yoshimasa ;
Tani, Tohru .
SURGERY TODAY, 2011, 41 (02) :197-202
[2]   Sentinel Node Biopsy in Head and Neck Squamous Cell Cancer: 5-Year Follow-Up of a European Multicenter Trial [J].
Alkureishi, Lee W. T. ;
Ross, Gary L. ;
Shoaib, Taimur ;
Soutar, David S. ;
Robertson, A. Gerry ;
Thompson, Richard ;
Hunter, Keith D. ;
Sorensen, Jens A. ;
Thomsen, Jorn ;
Krogdahl, Annelise ;
Alvarez, Julio ;
Barbier, Luis ;
Santamaria, Joseba ;
Poli, Tito ;
Sesenna, Enrico ;
Kovacs, Adorjan F. ;
Gruenwald, Frank ;
Barzan, Luigi ;
Sulfaro, Sandro ;
Alberti, Franco .
ANNALS OF SURGICAL ONCOLOGY, 2010, 17 (09) :2459-2464
[3]   Imaging and manipulation of single viruses by atomic force microscopy [J].
Baclayon, M. ;
Wuite, G. J. L. ;
Roos, W. H. .
SOFT MATTER, 2010, 6 (21) :5273-5285
[4]   ATOMIC FORCE MICROSCOPE [J].
BINNIG, G ;
QUATE, CF ;
GERBER, C .
PHYSICAL REVIEW LETTERS, 1986, 56 (09) :930-933
[5]   Sentinel lymph node mapping by indocyanin green fluorescence imaging in oropharyngeal cancer - preliminary experience [J].
Bredell, Marius G. .
HEAD & NECK ONCOLOGY, 2010, 2
[6]   Long-Term Experience in Sentinel Node Biopsy for Early Oral and Oropharyngeal Squamous Cell Carcinoma [J].
Broglie, Martina A. ;
Haile, Sarah R. ;
Stoeckli, Sandro J. .
ANNALS OF SURGICAL ONCOLOGY, 2011, 18 (10) :2732-2738
[7]   A self-assembled multimodal complex for combined pre- and intraoperative imaging of the sentinel lymph node [J].
Buckle, Tessa ;
van Leeuwen, Anne C. ;
Chin, Patrick T. K. ;
Janssen, Hans ;
Muller, Sara H. ;
Jonkers, Jos ;
van Leeuwen, Fijs W. B. .
NANOTECHNOLOGY, 2010, 21 (35)
[8]   Intraoperative Multispectral Fluorescence Imaging for the Detection of the Sentinel Lymph Node in Cervical Cancer: A Novel Concept [J].
Crane, Lucia M. A. ;
Themelis, George ;
Pleijhuis, Rick G. ;
Harlaar, Niels J. ;
Sarantopoulos, Athanasios ;
Arts, Henriette J. G. ;
van der Zee, Ate G. J. ;
Vasilis, Ntziachristos ;
van Dam, Gooitzen M. .
MOLECULAR IMAGING AND BIOLOGY, 2011, 13 (05) :1043-1049
[9]  
Dünne AA, 2002, ANTICANCER RES, V22, P3273
[10]   In vivo near-infrared fluorescence imaging [J].
Frangioni, JV .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2003, 7 (05) :626-634