Pediatric Emergency CT Scans at a Children's Hospital and at Community Hospitals: Radiation Technical Factors Are an Important Source of Radiation Exposure

被引:17
作者
Agarwal, Saurabh [1 ]
Jokerst, Clinton [2 ]
Siegel, Marilyn J. [1 ]
Hildebolt, Charles [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[2] Univ Arizona, Med Ctr, Tucson, AZ USA
关键词
children's hospital; community hospitals; CT; pediatrics; radiation; DOSE REDUCTION; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; UNITED-STATES; CANCER; TRENDS; RISKS; TOOLS; BODY;
D O I
10.2214/AJR.14.13715
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. This article compares the technical factors-in particular, tube current and voltage-and the resultant exposure to radiation associated with CT examinations performed at a children's hospital and at more general community hospital emergency departments (EDs). MATERIALS AND METHODS. CT scans obtained at community hospital EDs were retrospectively reviewed and compared with CT scans obtained at a children's hospital, to assess differences in kilovoltage, tube current, and volume CT dose index (CTDIvol) used. The number of scans obtained during the contrast-enhanced phase was also assessed. Parametric and nonparametric statistical analyses were used to test differences. RESULTS. A total of 233 body CT examinations were performed at community hospitals, and 287 were performed at a children's hospital. At both types of hospital, the median patient age was 12 years (p = 0.66). Of the body CT scans obtained at community hospitals that focused on the care of adult patients, 194 of 233 (83%) used a tube voltage of 120 kVp, 29 of 233 (12%) used 100 kVp, and two of 233 (< 1%) used 80 kVp. Of the body CT scans obtained at the children's hospital, 121 of 287 (42%) used a tube voltage of 120 kVp, 129 of 287 (45%) used 100 kVp, and 36 of 287 (13%) used 80 kVp. The median tube current was also lower at the children's hospital (110 vs 125 mA) (p < 0.001). At the community hospitals, 11 of 233 studies were multiphasic, whereas at the children's hospital, there were no multiphasic studies. For all CT types, the median CTDIvol was 4.9 mGy (range, 2.5-8.2 mGy) at the children's hospital and 8.6 mGy (range, 6.0-14.4 mGy) at the community hospitals (p < 0.001). CONCLUSION. The results of this study suggest that a large proportion of children who undergo CT at community hospitals receive relatively higher radiation doses than children who undergo CT at children's hospitals. This finding is related to the higher tube settings (in particular, kilovoltage) used at community hospitals.
引用
收藏
页码:409 / 413
页数:5
相关论文
共 32 条
[1]  
[Anonymous], ACR B
[2]   Dose reduction in pediatric CT: A rational approach [J].
Boone, JM ;
Geraghty, EM ;
Seibert, JA ;
Wootton-Gorges, SL .
RADIOLOGY, 2003, 228 (02) :352-360
[3]   Use of a Dedicated Pediatric CT Imaging Service Associated With Decreased Patient Radiation Dose [J].
Borders, Heather L. ;
Barnes, Courtney L. ;
Parks, David C. ;
Jacobsen, Jerilynn R. ;
Zhou, Yong ;
Hasselquist, Bruce E. ;
Betz, Bradford W. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2012, 9 (05) :340-343
[4]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[5]   Increasing utilization of computed tomography in the pediatric emergency department, 2000-2006 [J].
Broder J. ;
Fordham L.A. ;
Warshauer D.M. .
Emergency Radiology, 2007, 14 (4) :227-232
[6]   Strategies for formulating appropriate MDCT techniques when imaging the chest, abdomen, and pelvis in pediatric patients [J].
Cody, DD ;
Moxley, DM ;
Krugh, KT ;
O'Daniel, JC ;
Wagner, LK ;
Eftekhari, F .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) :849-859
[7]   Computed Tomography Use Among Children Presenting to Emergency Departments With Abdominal Pain [J].
Fahimi, Jahan ;
Herring, Andrew ;
Harries, Aaron ;
Gonzales, Ralph ;
Alter, Harrison .
PEDIATRICS, 2012, 130 (05) :E1069-E1075
[8]   Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose) [J].
Greess, H ;
Nömayr, A ;
Wolf, H ;
Baum, U ;
Lell, M ;
Böwing, B ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2002, 12 (06) :1571-1576
[9]   Ionizing Radiation in Abdominal CT: Unindicated Multiphase Scans Are an Important Source of Medically Unnecessary Exposure [J].
Guite, Kristie M. ;
Hinshaw, J. Louis ;
Ranallo, Frank N. ;
Lindstrom, Mary J. ;
Lee, Fred T., Jr. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2011, 8 (11) :756-761
[10]   Pediatric Abdominal Pain: Use of Imaging in the Emergency Department in the United States from 1999 to 2007 [J].
Hryhorczuk, Anastasia L. ;
Mannix, Rebekah C. ;
Taylor, George A. .
RADIOLOGY, 2012, 263 (03) :778-785