Selective Histamine Piezoelectric Chemosensor Using a Recognition Film of the Molecularly Imprinted Polymer of Bis(bithiophene) Derivatives

被引:101
|
作者
Pietrzyk, Agnieszka [1 ]
Suriyanarayanan, Subramanian [1 ]
Kutner, Wlodzimierz [1 ,2 ]
Chitta, Raghu [3 ]
D'Souza, Francis [3 ]
机构
[1] Polish Acad Sci, Inst Phys Chem, PL-01224 Warsaw, Poland
[2] Cardinal Stefan Wyszynski Univ, Sch Sci, Fac Math & Nat Sci, PL-01815 Warsaw, Poland
[3] Wichita State Univ, Wichita, KS 67260 USA
基金
美国国家科学基金会;
关键词
ELECTROCHEMICAL DETECTION; AMPEROMETRIC DETECTION; PERFORMANCE; DEHYDROGENASE; SENSORS; CELLS; IMMUNOSENSORS; SEROTONIN; RBL-2H3;
D O I
10.1021/ac8025652
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A histamine piezoelectric (acoustic) sensor using a molecularly imprinted polymer (MIP) film has been devised and tested. The sensor comprises an electrodeposited MIP film as the recognition element and a 10 MHz AT-cut shear-thickness-mode bulk-acoustic-wave quartz crystal resonator with Pt film electrodes as the signal transducer. Preparation of the sensing film involved two consecutive electrochemical polymerizations, performed under cyclic voltammetric conditions, with the use of a supporting electrolyte of 0.1 M tetra-n-butylammonium perchlorate in acetonitrile First, a poly(bithiophene) barrier film was deposited by electropolymerization on the Pt/quartz resonator to prevent histamine electro-oxidation and avoid possible contamination of the Pt electrode surface. Next, the histamine-templated MIP film was deposited by electropolymerization on top of this barrier film. For that purpose, two functional monomers of bis(bithiophene) derivatives, i.e., one bearing the 18-crown-6 and the other dioxoborinane substituent, were copolymerized in the presence of the histamine template. The consecutive growth of both these overlaid films was monitored with an electrochemical quartz crystal microbalance (EQCM). Subsequently, the histamine was extracted from MIP with 0.01 M NaOH for 12 h. The UV-vis and X-ray photoelectron spectroscopic measurements confirmed the completeness of the removal of the histamine template from the MIP film. The analytical performance of the chemosensor was assessed under flow injection analysis (FIA) conditions using the carrier 0.5 M HEPES buffer (pH = 7.5) solution and the piezoelectric microgravimetry detection at QCM. The negative peaks of resonant frequency linearly decreased with the increase of the histamine concentration in the range 10-100 mM for 150 mu L/min flow rate, and 100 mu L volume of the injected sample. The sensitivity of the chemosensor (0.33 Hz/mM) was more than twice as that of the chemosensor without the poly(bithiophene) barrier film (0.15 Hz/mM). The chemosensor performance was superior for selective histamine recognition if the poly(bithiophene) barrier film thickness exceeded 200 nm. The chemosensor discriminated histamine from functionally or structurally similar compounds, such as dopamine, tryptamine, and imidazole. Stability constants of the affinity complexes of MIP and analyte or the interfering agent were determined from kinetic studies. For the MIP-histamine complex, the stability constant thus evaluated was equal to 57.0 M-1 being much higher than those for the MIP-tryptamine and MIP-dopamine complexes determined to be 10.7, and 6.4 M-1, respectively. The concentration limit of detection was as low as 5 nM histamine if the carrier solution flow rate was as low as 35 mu L/min and the injection sample volume as large as 1 mL.
引用
收藏
页码:2633 / 2643
页数:11
相关论文
共 50 条
  • [1] Molecularly imprinted polymer (MIP) based piezoelectric microgravimetry chemosensor for selective determination of adenine
    Pietrzyk, Agnieszka
    Suriyanarayanan, Subramanian
    Kutner, Wlodzimierz
    Chitta, Raghu
    Zandler, Melvin E.
    D'Souza, Francis
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (11): : 2522 - 2529
  • [2] Selective recognition of ovalbumin using a molecularly imprinted polymer
    Su, Wei-Xiang
    Rick, John
    Chou, Tse-Chuan
    MICROCHEMICAL JOURNAL, 2009, 92 (02) : 123 - 128
  • [3] Melamine Acoustic Chemosensor Based on Molecularly Imprinted Polymer Film
    Pietrzyk, Agnieszka
    Kutner, Wlodzimierz
    Chitta, Raghu
    Zandler, Melvin E.
    D'Souza, Francis
    Sannicolo, Francesco
    Mussini, Patrizia R.
    ANALYTICAL CHEMISTRY, 2009, 81 (24) : 10061 - 10070
  • [4] Molecularly imprinted poly[bis(2,2′-bithienyl)methane] film with built-in molecular recognition sites for a piezoelectric microgravimetry chemosensor for selective determination of dopamine
    Pietrzyk, Agnieszka
    Suriyanarayanan, Subramanian
    Kutner, Wlodzimierz
    Maligaspe, Eranda
    Zandler, Melvin E.
    D'Souza, Francis
    BIOELECTROCHEMISTRY, 2010, 80 (01) : 62 - 72
  • [5] Molecularly imprinted polymer film grafted from porous silica for selective recognition of testosterone
    He, CY
    Liu, F
    Li, KA
    Liu, HW
    ANALYTICAL LETTERS, 2006, 39 (02) : 275 - 286
  • [6] Synthesis of a fluorescent molecularly imprinted polymer and its recognition property for histamine
    Dong, H
    Tong, AJ
    Li, LD
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2002, 23 (06): : 1018 - 1021
  • [7] Selective Recognition of Herbicides in Water Using a Fluorescent Molecularly Imprinted Polymer Sensor
    Limaee, Nargess Yousefi
    Rouhani, Shohre
    Olya, Mohammad Ebrahim
    Najafi, Farhood
    JOURNAL OF FLUORESCENCE, 2020, 30 (02) : 375 - 387
  • [8] Selective Recognition of Herbicides in Water Using a Fluorescent Molecularly Imprinted Polymer Sensor
    Nargess Yousefi Limaee
    Shohre Rouhani
    Mohammad Ebrahim Olya
    Farhood Najafi
    Journal of Fluorescence, 2020, 30 : 375 - 387
  • [9] Selective Recognition and Detoxification of Deltamethrin Using Molecularly Imprinted Polymer (MIP) Matrices
    Singh, K.P.
    Kumar, Ajeet
    Singh, P.
    Sanjesh
    Singh, Rakesh
    Pant, H.V.
    Analytical Chemistry Letters, 2013, 3 (01) : 30 - 39
  • [10] Potentiometric chemosensor for neopterin, a cancer biomarker, using an electrochemically synthesized molecularly imprinted polymer as the recognition unit
    Sharma, Piyush Sindhu
    Wojnarowicz, Agnieszka
    Sosnowska, Marta
    Benincori, Tiziana
    Noworyta, Krzysztof
    D'Souza, Francis
    Kutner, Wlodzimierz
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 565 - 572