Amperometric determination of serum lactate dehydrogenase activity using an ADP-modified graphite electrode

被引:3
作者
de los Santos-Alvarez, N [1 ]
Lobo-Castañón, MJ [1 ]
Miranda-Ordieres, AJ [1 ]
Tuñón-Blanco, P [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Oviedo 33006, Asturias, Spain
关键词
serum lactate dehydrogenase activity; ADP; NADH; modified electrode; electrocatalytic detection;
D O I
10.1016/S0003-2670(02)00055-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Graphite electrodes modified with a drop-coated layer of polyethyleneimine (PEI) and adenosine diphosphate (ADP) displayed an electrocatalytic response to NADH after the adenine moiety of ADP was electrochemically oxidised. NADH can be detected amperometrically in alkaline solution (pH 9.0) at low applied potentials (+50 mV (Ag/AgCl)). Using a stationary electrode arrangement, linear response for NADH concentrations between 1.0 x 10(-8) and 1.0 x 10(-4) M was found, with a response time of 12 s and a detection limit of 8 x 10(-9) M. The electrode was applied to the amperometric monitoring of the reaction between lactate and NAD(+) catalysed by lactate dehydrogenase (LDH). A flow injection-amperometric method for the determination of LDH activity in human serum was developed. The method allows a fast and accurate discrimination between pathological and normal LDH activity levels, with a sampling rate of 40 h(-1). Quantitative results for a random set of human serum samples were found to be in good agreement with the standard spectrophotometric method. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:275 / 284
页数:10
相关论文
共 50 条
  • [21] Mechanically immobilized copper hexacyanoferrate modified electrode for electrocatalysis and amperometric determination of glutathione
    Shankaran, DR
    Narayanan, SS
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2001, 22 (08) : 816 - 820
  • [22] A Doped Polyaniline Modified Electrode Amperometric Biosensor for Gluconic Acid Determination in Grapes
    Albanese, Donatella
    Malvano, Francesca
    Sannini, Adriana
    Pilloton, Roberto
    Di Matteo, Marisa
    SENSORS, 2014, 14 (06): : 11097 - 11109
  • [23] Voltammetric Determination of Boron using Poly Xylenol Orange-Modified Pencil Graphite Electrode
    Liv, Lokman
    Nakiboglu, Nuri
    ANALYTICAL LETTERS, 2018, 51 (1-2) : 170 - 185
  • [24] Determination of α-Lipoic acid on a Pyrolytic Graphite Electrode Modified with Cobalt Phthalocyanine
    Ferreira, Ana Paula M.
    dos Santos Pereira, Laise N.
    da Silva, Iranaldo Santos
    Tanaka, Sonia M. C. N.
    Tanaka, Auro A.
    Angnes, Lucio
    ELECTROANALYSIS, 2014, 26 (10) : 2138 - 2144
  • [25] Electrochemical determination of carboplatin in serum using a DNA-modified glassy carbon electrode
    Brett, AMO
    Serrano, SHP
    Macedo, TA
    Raimundo, D
    Marques, MH
    LaScalea, MA
    ELECTROANALYSIS, 1996, 8 (11) : 992 - 995
  • [26] Methylene Blue/Multiwall Carbon Nanotube Modified Electrode for the Amperometric Determination of Hydrogen Peroxide
    Pena, Roselyn C.
    Bertotti, Mauro
    Brett, Christopher M. A.
    ELECTROANALYSIS, 2011, 23 (10) : 2290 - 2296
  • [27] Amperometric determination of NADH with Co3O4 nanosheet modified electrode
    Chen, Chi-Hao
    Chen, Ying-Cih
    Lin, Meng-Shan
    BIOSENSORS & BIOELECTRONICS, 2013, 42 : 379 - 384
  • [28] Amperometric biosensor for ethanol based on immobilization of alcohol dehydrogenase on a nickel hexacyanoferrate modified microband gold electrode
    Cai, CX
    Xue, KH
    Zhou, YM
    Yang, H
    TALANTA, 1997, 44 (03) : 339 - 347
  • [29] Lactate Dehydrogenase Biosensor Based on an Hybrid Carbon Nanotube-Conducting Polymer Modified Electrode
    Aguei, L.
    Eguilaz, M.
    Pena-Farfal, C.
    Yanez-Sedeno, P.
    Pingarron, J. M.
    ELECTROANALYSIS, 2009, 21 (3-5) : 386 - 391
  • [30] Electrochemical Sensor Based on a Modified Graphite Screen Printed Electrode for Amitriptyline Determination
    Surface Engineering and Applied Electrochemistry, 2022, 58 : 100 - 108