Amperometric determination of serum lactate dehydrogenase activity using an ADP-modified graphite electrode

被引:3
作者
de los Santos-Alvarez, N [1 ]
Lobo-Castañón, MJ [1 ]
Miranda-Ordieres, AJ [1 ]
Tuñón-Blanco, P [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Oviedo 33006, Asturias, Spain
关键词
serum lactate dehydrogenase activity; ADP; NADH; modified electrode; electrocatalytic detection;
D O I
10.1016/S0003-2670(02)00055-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Graphite electrodes modified with a drop-coated layer of polyethyleneimine (PEI) and adenosine diphosphate (ADP) displayed an electrocatalytic response to NADH after the adenine moiety of ADP was electrochemically oxidised. NADH can be detected amperometrically in alkaline solution (pH 9.0) at low applied potentials (+50 mV (Ag/AgCl)). Using a stationary electrode arrangement, linear response for NADH concentrations between 1.0 x 10(-8) and 1.0 x 10(-4) M was found, with a response time of 12 s and a detection limit of 8 x 10(-9) M. The electrode was applied to the amperometric monitoring of the reaction between lactate and NAD(+) catalysed by lactate dehydrogenase (LDH). A flow injection-amperometric method for the determination of LDH activity in human serum was developed. The method allows a fast and accurate discrimination between pathological and normal LDH activity levels, with a sampling rate of 40 h(-1). Quantitative results for a random set of human serum samples were found to be in good agreement with the standard spectrophotometric method. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:275 / 284
页数:10
相关论文
共 50 条
  • [1] Determination of lactate dehydrogenase at a modified carbon fibre electrode
    Xi, LL
    Shi, QZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (12) : 1457 - 1460
  • [2] Modified carbon paste electrodes for flow injection amperometric determination of isocitrate dehydrogenase activity in serum
    Rodríguez-Granda, P
    Lobo-Castañón, MJ
    Miranda-Ordieres, AJ
    Tuñón-Blanco, P
    ANALYTICAL BIOCHEMISTRY, 2002, 308 (02) : 195 - 203
  • [3] Photometric flow system for the determination of serum lactate dehydrogenase activity
    Glowacka, Justyna
    Wisniewska, Agnieszka
    Koncki, Robert
    Strzelak, Kamil
    TALANTA, 2023, 265
  • [4] Amperometric determination of hydrazine at manganese hexacyanoferrate modified graphite-wax composite electrode
    Jayasri, D.
    Sriman Narayanan, S.
    JOURNAL OF HAZARDOUS MATERIALS, 2007, 144 (1-2) : 348 - 354
  • [5] Flow injection amperometric determination of NADH at a calmagite-modified pencil graphite electrode
    Mehmet Güneş
    Yusuf Dilgin
    Monatshefte für Chemie - Chemical Monthly, 2019, 150 : 1425 - 1432
  • [6] Flow injection amperometric determination of NADH at a calmagite-modified pencil graphite electrode
    Gunes, Mehmet
    Dilgin, Yusuf
    MONATSHEFTE FUR CHEMIE, 2019, 150 (08): : 1425 - 1432
  • [7] AMPEROMETRIC ENZYME ELECTRODE FOR NADH DETECTION EMPLOYING CO-IMMOBILIZED LACTATE-DEHYDROGENASE AND LACTATE OXIDASE
    SCOTT, DA
    SKILLEN, AW
    ANALYTICA CHIMICA ACTA, 1992, 256 (01) : 47 - 52
  • [8] Amperometric Determination of Acetaminophen (paracetamol) Using Graphene Oxide Modified Glassy Carbon Electrode
    Alagarsamy, Periyalagan
    Settu, Ramki
    Chen, Shen-Ming
    Chen, Tse-Wei
    Hong, In-Seok
    Rao, Mettu Mallikarjuna
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (08): : 7930 - 7938
  • [9] Amperometric determination of calcium ion with an alizarin/Nafion modified electrode
    Jo, GB
    Won, MS
    Shim, YB
    ELECTROANALYSIS, 1999, 11 (12) : 885 - 890
  • [10] Flow injection amperometric determination of hydrazine based on its electrocatalytic oxidation at pyrocatechol violet modified pencil graphite electrode
    Ayaz, Selen
    Dilgin, Yusuf
    ELECTROCHIMICA ACTA, 2017, 258 : 1086 - 1095