Diagnostic accuracy of optical coherence tomography for diagnosing glaucoma: secondary analyses of the GATE study

被引:14
作者
Virgili, Gianni [1 ]
Michelessi, Manuele [2 ]
Cook, Jonathan [3 ]
Boachie, Charles [4 ]
Burr, Jennifer [5 ]
Banister, Katie [6 ]
Garway-Heath, David F. [7 ,8 ]
Bourne, Rupert R. A. [9 ]
Asorey Garcia, Almudena [10 ]
Ramsay, Craig R. [6 ]
Azuara-Blanco, Augusto [11 ]
机构
[1] Univ Florence, Dept Translat Surg & Med, Eye Clin, Florence, Italy
[2] Fdn GB Bietti Studio & Ric Oftalmol, IRCCS, Dept Ophthalmol, Rome, Italy
[3] Univ Oxford, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Oxford, Oxon, England
[4] Univ Glasgow, Robertson Ctr Biostat, Glasgow, Lanark, Scotland
[5] Univ St Andrews, Sch Med, St Andrews, Fife, Scotland
[6] Univ Aberdeen, Hlth Serv Res Unit, Aberdeen, Scotland
[7] Moorfields Eye Hosp, NIHR Biomed Res Ctr, London, England
[8] UCL Inst Ophthalmol, London, England
[9] Anglia Ruskin Univ, Postgrad Inst, Vis & Eye Res Unit, Cambridge, England
[10] Hosp San Carlos, Dept Ophthalmol, Madrid, Spain
[11] Queens Univ Belfast, Ctr Publ Hlth, Belfast, Antrim, North Ireland
关键词
NERVE-FIBER LAYER; SPECTRUM BIAS; GDX VCC; TECHNOLOGIES; ABILITY;
D O I
10.1136/bjophthalmol-2017-310642
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/Aims To assess the diagnostic performance of retinal nerve fibre layer (RNFL) data of optical coherence tomography (OCT) for detecting glaucoma. Methods Secondary analyses of a prospective, multicentre diagnostic study (Glaucoma Automated Tests Evaluation (GATE)) referred to hospital eye services in the UK were conducted. We included data from 899 of 966 participants referred to hospital eye services with suspected glaucoma or ocular hypertension. We used both eyes' data and logistic regression-based receiver operator characteristics analysis to build a set of models to measure the sensitivity and specificity of the average and inferior quadrant RNFL thickness data of OCT. The reference standard was expert clinician examination including automated perimetry. The main outcome measures were sensitivity at 0.95 specificity and specificity at 0.95 sensitivity and the corresponding RNFL thickness thresholds. We explored the possibility of accuracy improvement by adding measures of within-eye and between-eye variation, scan quality, intraocular pressure (IOP) and age. Results Glaucoma was diagnosed in at least one eye in 17% of participants. Areas under the curve were between 0.83 and 0.88. When specificity was fixed at 0.95, the sensitivity was between 0.38 and 0.55, and the highest values were reached with models including the inferior quadrant rather than the average RNFL thickness. Fixing sensitivity at 0.95, the specificity was between 0.36 and 0.58. The addition of age, refractive error, IOP or within-subject variation did not improve the accuracy. Conclusion RNFL thickness data of OCT can be used as a diagnostic test, but accuracy estimates remain moderate even in exploratory multivariable modelling of aiming to improve accuracy.
引用
收藏
页码:604 / 610
页数:7
相关论文
共 19 条
[1]   Comparative Assessment for the Ability of Cirrus, RTVue, and 3D-OCT to Diagnose Glaucoma [J].
Akashi, Azusa ;
Kanamori, Akiyasu ;
Nakamura, Makoto ;
Fujihara, Masashi ;
Yamada, Yuko ;
Negi, Akira .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (07) :4478-4484
[2]   Automated imaging technologies for the diagnosis of glaucoma: a comparative diagnostic study for the evaluation of the diagnostic accuracy, performance as triage tests and cost-effectiveness (GATE study) [J].
Azuara-Blanco, Augusto ;
Banister, Katie ;
Boachie, Charles ;
McMeekin, Peter ;
Gray, Joanne ;
Burr, Jennifer ;
Bourne, Rupert ;
Garway-Heath, David ;
Batterbury, Mark ;
Hernandez, Rodolfo ;
McPherson, Gladys ;
Ramsay, Craig ;
Cook, Jonathan .
HEALTH TECHNOLOGY ASSESSMENT, 2016, 20 (08) :1-+
[3]   Optic disk and nerve fiber layer Imaging to detect glaucoma [J].
Badala, Federico ;
Nouri-Mahdavi, Kouros ;
Raoof, Duna A. ;
Leeprechanon, Narakorn ;
Law, Simon K. ;
Caprioli, Joseph .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (05) :724-732
[4]   Can Automated Imaging for Optic Disc and Retinal Nerve Fiber Layer Analysis Aid Glaucoma Detection? [J].
Banister, Katie ;
Boachie, Charles ;
Bourne, Rupert ;
Cook, Jonathan ;
Burr, Jennifer M. ;
Ramsay, Craig ;
Garway-Heath, David ;
Gray, Joanne ;
McMeekin, Peter ;
Hernandez, Rodolfo ;
Azuara-Blanco, Augusto .
OPHTHALMOLOGY, 2016, 123 (05) :930-938
[5]   Diagnostic Accuracy of Technologies for Glaucoma Case-Finding in a Community Setting [J].
Dabasia, Priya L. ;
Fidalgo, Bruno R. ;
Edgar, David F. ;
Garway-Heath, David F. ;
Lawrenson, John G. .
OPHTHALMOLOGY, 2015, 122 (12) :2407-2415
[6]   Comparison of diagnostic accuracy of heidelberg retina tomograph II and heidelberg retina tomograph 3 to discriminate glaucomatous and nonglaucomatous eyes [J].
De Leon-Ortega, Julio E. ;
Sakata, Lisandro M. ;
Monheit, Blythe E. ;
Mcgwin, Gerald, Jr. ;
Arthur, Stella N. ;
Girkin, Christopher A. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (04) :525-532
[7]   Diagnostic ability of the Heidelberg Retina Tomograph 3 for glaucoma [J].
Ferreras, Antonio ;
Pablo, Luis E. ;
Pajarin, Ana B. ;
Larrosa, Jose M. ;
Polo, Vicente ;
Pueyo, Victoria .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (02) :354-359
[8]   Detection of incident field loss using the glaucoma hemifield test [J].
Katz, J ;
Quigley, HA ;
Sommer, A .
OPHTHALMOLOGY, 1996, 103 (04) :657-663
[9]   Asymmetries and visual field summaries as predictors of glaucoma in the Ocular Hypertension Treatment Study [J].
Levine, Richard A. ;
Demirel, Shaban ;
Fan, Juanjuan ;
Keltner, John L. ;
Johnson, Chris A. ;
Kass, Michael A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (09) :3896-3903
[10]   Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma [J].
Medeiros, FA ;
Zangwill, LM ;
Bowd, C ;
Weinreb, RN .
ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (06) :827-837