Quality Specifications for the Determination of Copper, Zinc, and Selenium in Human Serum or Plasma: Evaluation of an Approach Based on Biological and Analytical Variation

被引:27
作者
Arnaud, Josiane [1 ]
Weber, Jean-Philippe [2 ]
Weykamp, Cas W.
Parsons, Patrick J. [3 ]
Angerer, Jurgen [4 ]
Mairiaux, Eric [5 ]
Mazarrasa, Olav [6 ]
Valkonen, Sinikka [7 ]
Menditto, Antonio [8 ]
Patriarca, Marina [8 ]
Taylor, Andrew [9 ]
机构
[1] CHU Grenoble, Dept Biol Integree, F-38043 Grenoble 9, France
[2] Inst Natl Sante Publ Quebec, Ctr Toxicol, Quebec City, PQ, Canada
[3] New York State Dept Hlth, Trace Elements Lab, Wadsworth Ctr, Albany, NY USA
[4] Univ Erlangen Nurnberg, Inst Occupat Social & Environm Med, Erlangen, Germany
[5] Sci Inst Publ Hlth, Bur Qual Assurance, Brussels, Belgium
[6] Higiene Ind, Ctr Seguridad & Salud Trabajo, Santander, Spain
[7] Finnish Inst Occupat Hlth, Biomonitoring Lab, Helsinki, Finland
[8] Ist Super Sanita, Dipartimento Santa Alimentare & Anim, I-00161 Rome, Italy
[9] Univ Surrey, Ctr Clin Sci & Measurement, Sch Biomed & Life Sci, Guildford GU2 5XH, Surrey, England
关键词
D O I
10.1373/clinchem.2008.108142
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Trace element external quality assessment schemes monitor laboratory performance and provide a stimulus for improvement in accuracy. However, monitoring of participant performance varies according to the scheme and can lead to conflicting conclusions. METHODS: Quality specifications based on biological intra- and interindividual variability were calculated and compared to those currently used by various trace element external quality assessment schemes for plasma or serum copper, zinc, and Selenium concentrations. For this purpose, we evaluated results reported by participating laboratories in different schemes, at key concentrations, using z scores. RESULTS: Minimal quality specifications developed from the biological intra- and interindividUal variability were, for Cu, +/- 0.84 mu mol/L or 12% of the assigned target concentration, whichever is greater; for Zn, +/- 1.20 mu mol/L, or 15% of the assigned target concentration, whichever is greater; and for Se, +/- 0.072 mu mol/L, or 12% of the assigned target concentration, whichever is greater. Reported performance of the participating laboratories depended on analyte, concentration, and the selected quality specification. In addition, the most commonly used methods for the determination of Cu, Zn, and Se may give different results. CONCLUSIONs: The proposed minimal quality specifications based on biological variation are generally slightly less stringent than those currently in use, although they do not drastically change the performance evaluation in the different schemes. These specifications are a first step in the harmonization of practices among the schemes and remain to be evaluated. (C) 2008 American Association for Clinical Chemistry
引用
收藏
页码:1892 / 1899
页数:8
相关论文
共 39 条
[1]   Copper deficiency and excess in infancy: Developing a research agenda [J].
Araya, M ;
Koletzko, B ;
Uauy, R .
JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2003, 37 (04) :422-429
[2]   Clinical conditions altering copper metabolism in humans [J].
Beshgetoor, D ;
Hambidge, M .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1998, 67 (05) :1017S-1021S
[3]   The Role of Selenium in Chronic Disease [J].
Boosalis, Maria G. .
NUTRITION IN CLINICAL PRACTICE, 2008, 23 (02) :152-160
[4]  
Brown K M, 2001, Public Health Nutr, V4, P593
[5]  
Christensen J M, 1996, Ann Ist Super Sanita, V32, P285
[6]   Clinical manifestations of nutritional copper deficiency in infants and children [J].
Cordano, A .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1998, 67 (05) :1012S-1016S
[7]   General strategies to set quality specifications for reliability performance characteristics [J].
Fraser, CG .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1999, 59 (07) :487-490
[8]  
GALLAGHER SK, 1989, CLIN CHEM, V35, P369
[9]  
Gensler G, 2002, J NUTR, V132, P697
[10]  
GONZALEZREVALDERIA J, 1990, CLIN CHEM, V36, P2140