Relationship between prognostic factors of breast cancer and 99mTc-sestamibi uptake in patients who underwent scintimammography:: Multivariate analysis of causes of false-negative results

被引:3
|
作者
Lumachi, F [1 ]
Ermani, M
Marzola, MC
Zucchetta, P
Cecchin, D
Basso, SMM
Brandes, AA
Bui, F
机构
[1] Univ Padua, Sch Med, Dept Surg & Gastroenterol Surg, Breast Surg Unit, I-35128 Padua, Italy
[2] Univ Padua, Sch Med, Dept Neurosci, Biostat Sect, I-35128 Padua, Italy
[3] Univ Padua, Sch Med, Dept Diagnost Med Sci, Nucl Med Serv, I-35128 Padua, Italy
[4] Azienda Osped, Div Clin Oncol, I-35128 Padua, Italy
关键词
scintimammography; breast cancer; prognostic factors; diagnosis; multivariate analysis;
D O I
10.1016/j.breast.2005.03.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The complementary role of sestamibi scintimammography (SSM) in patients with breast cancer (BC) is well established. The aim of this study was to establish whether a relationship exists between sestamibi uptake, evaluated as a tumour-to-background ratio (TBR), and the main prognostic factors of BC. SSM with the measurement of TBR was performed preoperativety in 102 women (median age 57 years, range 32-81 years) who underwent curative surgery for primary BC. Final pathology showed 4 (3.9%) with pT1a, 17 (16.7%) with pT1b, 44 (43.1%) with pT1c and 37 (36.3%) with pT2 breast carcinomas. The overall sensitivity of SSM was 80.4%. An ANOVA showed significant (P < 0.01) differences between the TBR of patients with G1 vs. G3 tumours, and between the TBR of those with G2 vs. G3 breast carcinomas. Moreover, there was a difference (P = 0.021) between the TBR of patients (n = 12, 11.8%) with CEA serum levels > 10 ng/mt (2.031 +/- 0.420), and those with normal (n = 90, 88.2%) CEA values (1.713 +/- 0.446), whitst no difference (P = NS) was found between patients (n = 27, 26.5%) with CA 15-3 > 30 U/ml (1.893 +/- 0.401) and those with normal (n = 75, 73.5%) CA 15-3 values (1.699 +/- 0.462). There was a mild inverse correlation between TBR and both the oestrogen (R = 0.25, P = 0.011) and the progesterone receptor (R = 0.23, P = 0.02) rate. The logistic regression analysis showed that only size and CA 15-3 serum levels represent true independent parameters, but the function was able to predict only 11 out of 21 (52.4%) patients with false-negative SSM. TBR is independent of age and mainly correlates with the size of the tumour. There are no reliable preoperative prognostic factors that are really useful for improving SSM sensitivity in patients with small breast carcinomas. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:130 / 134
页数:5
相关论文
共 8 条
  • [1] Is 99mTc-sestamibi scintimammography complementary to conventional mammography for detecting breast cancer in patients with palpable masses?
    Alonso, O
    Massardo, T
    Delgado, LB
    Horvath, J
    Kabasakal, L
    Llamas-Olier, A
    Maunda, KK
    Morales, R
    Padhy, AK
    Shankar, UR
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (11) : 1614 - 1621
  • [2] Axillary lymph node Metastases detection with 99mTc-sestamibi scintimammography in patients with breast cancer undergoing curative surgery
    Lumachi, Franco
    Ferretti, Guido
    Povolato, Michele
    Bui, Franco
    Cecchin, Diego
    Marzola, Maria Cristina
    Zucchetta, Pietro
    Basso, Umberto
    ANTICANCER RESEARCH, 2007, 27 (4C) : 2949 - 2952
  • [3] Tissue-specific effects on uptake of 99mTc-sestamibi by breast lesions:: A targeted analysis of false scintigraphic diagnoses
    Tiling, R
    Stephan, K
    Sommer, H
    Shabani, N
    Linke, R
    Hahn, K
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (11) : 1822 - 1828
  • [4] Accuracy of ultrasonography and 99mTc-sestamibi scintimammography for assessing axillary lymph node status in breast cancer patients.: A prospective study
    Lumachi, F.
    Tregnaghi, A.
    Ferretti, G.
    Povolato, M.
    Marzola, M. C.
    Zucchetta, P.
    Cecchin, D.
    Bui, F.
    EJSO, 2006, 32 (09): : 933 - 936
  • [5] Correlation between uptake of Tc-99m SestaMIBI and prognostic factors of breast cancer
    Cwikla, JB
    Buscombe, JR
    Kolasinska, AD
    Parbhoo, SP
    Thakrar, DS
    Hilson, AJW
    ANTICANCER RESEARCH, 1999, 19 (3B) : 2299 - 2304
  • [7] False-negative results of breast MR computer-aided evaluation in patients with breast cancer: correlation with clinicopathologic and radiologic factors
    Shin, YunKyung
    Sohn, Yu-Mee
    Seo, Mirinae
    Han, Kyunghwa
    CLINICAL IMAGING, 2016, 40 (06) : 1086 - 1091
  • [8] Analysis of the causes of false negative and false positive results of preoperative axillary ultrasound in patients with early breast cancer - a single-centre study
    Nowikiewicz, Tomasz
    Nowak, Adam
    Wisniewska, Magdalena
    Wisniewski, Michal
    Nowikiewicz, Magdalena
    Zegarski, Wojciech
    WSPOLCZESNA ONKOLOGIA-CONTEMPORARY ONCOLOGY, 2018, 22 (04): : 247 - 251