Use of radiochromic film dosimetry in radiobiology experiments

被引:4
|
作者
Torres del Rio, Julia [1 ]
Forastero, Cristina [1 ]
Moreno-Torres, Miguel [2 ]
Molina-Matas, Maria [3 ]
Martinez-Felipe, Ana M. [4 ]
Moreno, Alvaro [5 ]
Lopez-Penalver, Jesus J. [6 ]
Guirado, Damian [1 ]
机构
[1] Hosp Univ San Cecilio Granada, Serv Radiofis, E-18016 Granada, Spain
[2] Genesiscare Toledo, Carretera Peraleda 5, E-45004 Toledo, Spain
[3] Fdn Reina Sofia, Ctr Alzheimer, E-28031 Madrid, Spain
[4] Univ Granada, Dept Radiol & Med Fis, E-18016 Granada, Spain
[5] Rijk Zwaan Iberica, E-04120 Almeria, Spain
[6] Univ Granada, Ctr Instrumentac Cient, Unidad Radiol Expt, E-18100 Granada, Spain
关键词
Radiobiology; Dosimetry; Radiochromic film; EBT3; DOSE-RESPONSE CURVE; GAFCHROMIC EBT2; IRRADIATION; RADIOTHERAPY; ELECTRON; POLLEN;
D O I
10.1016/j.radphyschem.2018.10.008
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In radiobiology experiments, that usually entail unique irradiation geometries, it is necessary to know properly the absorbed doses involved. It is difficult to find them out, due to the differences between these irradiation conditions and the reference conditions in which the absorbed dose is measured by the usual ionometric procedures. The aim of this study is to check the EBT3 radiochromic film as a dosimetric system for x-ray beams used in radiobiology experiments. The film has been calibrated in different energy photon beams, so its energy independence has been proved. Afterwards it has been used to evaluate the absorbed dose in two radiobiology experiments: first one required the irradiation of flowers, while in the second, mice with implanted tumors were irradiated. In both cases EBT3 radiochromic film has shown to be a suitable tool for measuring the absorbed dose in this kind of experiments.
引用
收藏
页码:169 / 173
页数:5
相关论文
共 50 条
  • [41] Radiochromic film dosimetry: Reflection vs transmission scanning
    Kalef-Ezra, J.
    Karava, K.
    MEDICAL PHYSICS, 2008, 35 (06) : 2308 - 2311
  • [42] Comparison of 4 multichannel radiochromic film dosimetry procedures
    Berenguer, R.
    Gutierrez-Perez, M.
    Rivera, M.
    Nunez-Quintanilla, A. T.
    De la Vara, V.
    Sabater, S.
    Villas-Sanchez, M. V.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S733 - S734
  • [43] Reference radiochromic film dosimetry: Review of technical aspects
    Devic, Slobodan
    Tomic, Nada
    Lewis, David
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (04): : 541 - 556
  • [44] Radiochromic film dosimetry of a low energy proton beam
    Piermattei, A
    Miceli, R
    Azario, L
    Fidanzio, A
    delle Canne, S
    De Angelis, C
    Onori, S
    Pacilio, M
    Petetti, E
    Raffaele, L
    Sabini, MG
    MEDICAL PHYSICS, 2000, 27 (07) : 1655 - 1660
  • [45] Dosimetric characteristics of a new radiochromic film for IMRT dosimetry
    Soares, C
    Lombardi, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1725 - 1725
  • [46] On the re-calibration process in radiochromic film dosimetry
    Ruiz-Morales, Carmen
    Antonio Vera-Sanchez, Juan
    Gonzalez-Lopez, Antonio
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 42 : 67 - 75
  • [47] A rapid colour stabilization technique for radiochromic film dosimetry
    Reinstein, LE
    Gluckman, GR
    Meek, AG
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10): : 2703 - 2708
  • [48] Radiochromic film dosimetry for a new electronic brachytherapy source
    Chiu-Tsao, S
    Rusch, T
    Axelrod, S
    Tsao, H
    Harrison, L
    MEDICAL PHYSICS, 2004, 31 (06) : 1913 - 1913
  • [49] LINEARIZATION OF THE RADIOCHROMIC FILM DOSIMETRY SYSTEM DOSE RESPONSE
    Tomic, Nada
    Seuntjens, Jan
    DeBlois, Francois
    Devic, Slobodan
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S9 - S10
  • [50] Longitudinal radiochromic-film dosimetry for carbonion radiotherapy
    Kanematsu, N.
    Mizuno, H.
    Nakaji, T.
    Yonai, S.
    Matsumoto, S.
    Inaniwa, T.
    RADIOTHERAPY AND ONCOLOGY, 2019, 141 : S82 - S83