Use of radiochromic film dosimetry in radiobiology experiments

被引:4
|
作者
Torres del Rio, Julia [1 ]
Forastero, Cristina [1 ]
Moreno-Torres, Miguel [2 ]
Molina-Matas, Maria [3 ]
Martinez-Felipe, Ana M. [4 ]
Moreno, Alvaro [5 ]
Lopez-Penalver, Jesus J. [6 ]
Guirado, Damian [1 ]
机构
[1] Hosp Univ San Cecilio Granada, Serv Radiofis, E-18016 Granada, Spain
[2] Genesiscare Toledo, Carretera Peraleda 5, E-45004 Toledo, Spain
[3] Fdn Reina Sofia, Ctr Alzheimer, E-28031 Madrid, Spain
[4] Univ Granada, Dept Radiol & Med Fis, E-18016 Granada, Spain
[5] Rijk Zwaan Iberica, E-04120 Almeria, Spain
[6] Univ Granada, Ctr Instrumentac Cient, Unidad Radiol Expt, E-18100 Granada, Spain
关键词
Radiobiology; Dosimetry; Radiochromic film; EBT3; DOSE-RESPONSE CURVE; GAFCHROMIC EBT2; IRRADIATION; RADIOTHERAPY; ELECTRON; POLLEN;
D O I
10.1016/j.radphyschem.2018.10.008
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In radiobiology experiments, that usually entail unique irradiation geometries, it is necessary to know properly the absorbed doses involved. It is difficult to find them out, due to the differences between these irradiation conditions and the reference conditions in which the absorbed dose is measured by the usual ionometric procedures. The aim of this study is to check the EBT3 radiochromic film as a dosimetric system for x-ray beams used in radiobiology experiments. The film has been calibrated in different energy photon beams, so its energy independence has been proved. Afterwards it has been used to evaluate the absorbed dose in two radiobiology experiments: first one required the irradiation of flowers, while in the second, mice with implanted tumors were irradiated. In both cases EBT3 radiochromic film has shown to be a suitable tool for measuring the absorbed dose in this kind of experiments.
引用
收藏
页码:169 / 173
页数:5
相关论文
共 50 条
  • [1] Use of a control film piece in radiochromic film dosimetry
    Aldelaijan, Saad
    Alzorkany, Faisal
    Moftah, Belal
    Buzurovic, Ivan
    Seuntjens, Jan
    Tomic, Nada
    Devic, Slobodan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01): : 202 - 207
  • [2] Radiochromic film dosimetry
    Soares, Christopher G.
    RADIATION MEASUREMENTS, 2006, 41 : S100 - S116
  • [3] Dosimetry for radiobiology experiments at GANIL
    Durantel, Florent
    Balanzat, Emmanuel
    Cassimi, Amine
    Chevalier, Francois
    Ngono-Ravache, Yvette
    Madi, Toiammou
    Poully, Jean-Christophe
    Ramillon, Jean -Marc
    Rothard, Hermann
    Ropars, Frederic
    Schwob, Lucas
    Testard, Isabelle
    Saintigny, Yannick
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 816 : 70 - 77
  • [4] Dosimetry as a Catch in Radiobiology Experiments
    Sefl, Martin
    Brabcova, Katerina Pachnerova
    Stepan, Vaclav
    RADIATION RESEARCH, 2018, 190 (04) : 404 - 411
  • [5] Radiochromic Film Dosimetry Update
    Niroomand-Rad, A.
    Chiu-Tsao, S.
    Trichter, S.
    Das, I.
    MEDICAL PHYSICS, 2015, 42 (06) : 3626 - 3626
  • [6] Eigencolor radiochromic film dosimetry
    Bouchard, Hugo
    Billas, Ilias
    Subiel, Anna
    Duane, Simon
    MEDICAL PHYSICS, 2021, 48 (05) : 2592 - 2603
  • [7] A RADIOCHROMIC DYE FILM FOR UV DOSIMETRY
    REHIM, FA
    GAWAD, ASA
    FATTAH, AAA
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 1992, 64 (01) : 123 - 131
  • [8] New developments in radiochromic film dosimetry
    Soares, C. G.
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 100 - 106
  • [9] Radiochromic film dosimetry in water phantoms
    Butson, MJ
    Cheung, T
    Yu, PKN
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (01): : N27 - N31
  • [10] Ultraviolet radiation dosimetry with radiochromic film
    Butson, MJ
    Cheung, T
    Yu, PKN
    Abbati, D
    Greenoak, GE
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07): : 1863 - 1868